{"title":"通过特定的配电馈线改进来减少瞬时停电","authors":"B. D. Coate, D. Wareham","doi":"10.1109/REPCON.2000.848035","DOIUrl":null,"url":null,"abstract":"This paper presents a cost-effective method of reducing momentary interruptions. Two main concepts are discussed. The first is targeting selected zones with increased maintenance to improve overall reliability of the entire feeder, and the second is overcurrent coordination for trip saving on the substation feeder circuit breaker. Trip saving is the intentional coordination of tap fuses off main feeders so that a fault on the tap will not cause a fast operation of the main breaker. Other topics discussed are the re-setting of instantaneous tripping of the substation breaker, use of tap reclosers, and increasing lightning/animal protection on key parts of the feeder.","PeriodicalId":306493,"journal":{"name":"2000 Rural Electric Power Conference. Papers Presented at the 44th Annual Conference (Cat. No.00CH37071)","volume":"436 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Decreasing momentary outages with specific distribution feeder improvements\",\"authors\":\"B. D. Coate, D. Wareham\",\"doi\":\"10.1109/REPCON.2000.848035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a cost-effective method of reducing momentary interruptions. Two main concepts are discussed. The first is targeting selected zones with increased maintenance to improve overall reliability of the entire feeder, and the second is overcurrent coordination for trip saving on the substation feeder circuit breaker. Trip saving is the intentional coordination of tap fuses off main feeders so that a fault on the tap will not cause a fast operation of the main breaker. Other topics discussed are the re-setting of instantaneous tripping of the substation breaker, use of tap reclosers, and increasing lightning/animal protection on key parts of the feeder.\",\"PeriodicalId\":306493,\"journal\":{\"name\":\"2000 Rural Electric Power Conference. Papers Presented at the 44th Annual Conference (Cat. No.00CH37071)\",\"volume\":\"436 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 Rural Electric Power Conference. Papers Presented at the 44th Annual Conference (Cat. No.00CH37071)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REPCON.2000.848035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 Rural Electric Power Conference. Papers Presented at the 44th Annual Conference (Cat. No.00CH37071)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REPCON.2000.848035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Decreasing momentary outages with specific distribution feeder improvements
This paper presents a cost-effective method of reducing momentary interruptions. Two main concepts are discussed. The first is targeting selected zones with increased maintenance to improve overall reliability of the entire feeder, and the second is overcurrent coordination for trip saving on the substation feeder circuit breaker. Trip saving is the intentional coordination of tap fuses off main feeders so that a fault on the tap will not cause a fast operation of the main breaker. Other topics discussed are the re-setting of instantaneous tripping of the substation breaker, use of tap reclosers, and increasing lightning/animal protection on key parts of the feeder.