{"title":"质子治疗联合PET监测的可行性研究","authors":"A. Paans, J. Schippers","doi":"10.1109/NSSMIC.1992.301094","DOIUrl":null,"url":null,"abstract":"To evaluate the possibility of combining proton therapy with positron emission tomography (PET) as a therapy monitor and as a tool for in situ dosimetry during therapy, proton activation experiments have been performed using a 55-MeV proton beam on two different materials. The three-dimensional measurements of the induced activity with PET are compared with the calculated dose distribution and with model calculations. It is concluded that the radioactivity induced by proton beams in tissue-like (consisting mainly of C, N and O) materials can be measured accurately by means of PET. It is expected that the rather low amount of activity created during a therapy treatment can be detected with sufficient accuracy; in particular, the region preceding the Bragg peak in the dose distribution can be monitored quite well with this method.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"66","resultStr":"{\"title\":\"Proton therapy in combination with PET as monitor: a feasibility study\",\"authors\":\"A. Paans, J. Schippers\",\"doi\":\"10.1109/NSSMIC.1992.301094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To evaluate the possibility of combining proton therapy with positron emission tomography (PET) as a therapy monitor and as a tool for in situ dosimetry during therapy, proton activation experiments have been performed using a 55-MeV proton beam on two different materials. The three-dimensional measurements of the induced activity with PET are compared with the calculated dose distribution and with model calculations. It is concluded that the radioactivity induced by proton beams in tissue-like (consisting mainly of C, N and O) materials can be measured accurately by means of PET. It is expected that the rather low amount of activity created during a therapy treatment can be detected with sufficient accuracy; in particular, the region preceding the Bragg peak in the dose distribution can be monitored quite well with this method.<<ETX>>\",\"PeriodicalId\":447239,\"journal\":{\"name\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"66\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1992.301094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 66

摘要

为了评估将质子治疗与正电子发射断层扫描(PET)结合作为治疗监测和治疗期间原位剂量测定工具的可能性,在两种不同的材料上使用55-MeV质子束进行了质子激活实验。将PET诱导活度的三维测量结果与计算剂量分布和模型计算结果进行了比较。结果表明,质子束在类组织(主要由C、N、O组成)材料中所引起的放射性可以用PET精确测量。预期在治疗治疗期间产生的相当低的活性量可以足够准确地检测到;特别是,用这种方法可以很好地监测剂量分布中布拉格峰之前的区域
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Proton therapy in combination with PET as monitor: a feasibility study
To evaluate the possibility of combining proton therapy with positron emission tomography (PET) as a therapy monitor and as a tool for in situ dosimetry during therapy, proton activation experiments have been performed using a 55-MeV proton beam on two different materials. The three-dimensional measurements of the induced activity with PET are compared with the calculated dose distribution and with model calculations. It is concluded that the radioactivity induced by proton beams in tissue-like (consisting mainly of C, N and O) materials can be measured accurately by means of PET. It is expected that the rather low amount of activity created during a therapy treatment can be detected with sufficient accuracy; in particular, the region preceding the Bragg peak in the dose distribution can be monitored quite well with this method.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Results in online data processing in the data acquisition system of the ALEPH TPC Practical evaluation of several cone beam orbits for SPECT Model based scatter correction in three dimensions (positron emission tomography) Macintosh software for simulating resolution and scatter effects in PET Testing fast ADC's at sample rates between 20 and 140 MSPS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1