12脉冲相位控制AC/DC变换器分析

T. Liang, Jiann-Fuh Chen, C. Chu, Kuen-Jyh Chen
{"title":"12脉冲相位控制AC/DC变换器分析","authors":"T. Liang, Jiann-Fuh Chen, C. Chu, Kuen-Jyh Chen","doi":"10.1109/PEDS.1999.792804","DOIUrl":null,"url":null,"abstract":"In this paper, the unbalanced current in the 12-pulse phase control AC/DC converters was studied. The 12-pulse /spl Delta/-Y type AC/DC converter will keep a balanced voltage with 30/spl deg/ phase shifted at the low coupling coefficient condition, but an unbalanced current will be obtained in the 12-pulse autotransformer phase shift AC/DC converter at the low coupling coefficient condition. The theoretical phasor analysis of the unbalanced current was presented and a feedback controller was designed to overcome this problem. Finally, a 3 kW 12-pulse autotransformer phase shifted AC/DC converter was implemented to demonstrate the theoretical analysis.","PeriodicalId":254764,"journal":{"name":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Analysis of 12 pulse phase control AC/DC converter\",\"authors\":\"T. Liang, Jiann-Fuh Chen, C. Chu, Kuen-Jyh Chen\",\"doi\":\"10.1109/PEDS.1999.792804\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the unbalanced current in the 12-pulse phase control AC/DC converters was studied. The 12-pulse /spl Delta/-Y type AC/DC converter will keep a balanced voltage with 30/spl deg/ phase shifted at the low coupling coefficient condition, but an unbalanced current will be obtained in the 12-pulse autotransformer phase shift AC/DC converter at the low coupling coefficient condition. The theoretical phasor analysis of the unbalanced current was presented and a feedback controller was designed to overcome this problem. Finally, a 3 kW 12-pulse autotransformer phase shifted AC/DC converter was implemented to demonstrate the theoretical analysis.\",\"PeriodicalId\":254764,\"journal\":{\"name\":\"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.1999.792804\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.1999.792804","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

本文研究了12脉冲相位控制AC/DC变换器中的不平衡电流。12脉冲/spl Delta/-Y型AC/DC变换器在低耦合系数条件下能保持30/spl度/相移的平衡电压,而在低耦合系数条件下,12脉冲自耦移相AC/DC变换器会产生不平衡电流。对不平衡电流的相量进行了理论分析,设计了一种反馈控制器来克服这一问题。最后,实现了一个3kw的12脉冲自耦移相AC/DC变换器来验证理论分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of 12 pulse phase control AC/DC converter
In this paper, the unbalanced current in the 12-pulse phase control AC/DC converters was studied. The 12-pulse /spl Delta/-Y type AC/DC converter will keep a balanced voltage with 30/spl deg/ phase shifted at the low coupling coefficient condition, but an unbalanced current will be obtained in the 12-pulse autotransformer phase shift AC/DC converter at the low coupling coefficient condition. The theoretical phasor analysis of the unbalanced current was presented and a feedback controller was designed to overcome this problem. Finally, a 3 kW 12-pulse autotransformer phase shifted AC/DC converter was implemented to demonstrate the theoretical analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamic analysis of electromechanical converters by means of the wavelet transform Analysis of the snubberless operation of the emitter turn-off thyristor (ETO) Modeling and control of automotive HID lamp ballast Voltage and current hybrid controlled PWM inverters using variable structure control Development of a fuel cell power conditioner system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1