S. El-Samad, D. Obeid, G. Zaharia, S. Sadek, G. El Zein
{"title":"利用连续波多普勒雷达探测墙后心跳的可行性","authors":"S. El-Samad, D. Obeid, G. Zaharia, S. Sadek, G. El Zein","doi":"10.1109/MECAP.2016.7790091","DOIUrl":null,"url":null,"abstract":"This paper presents a wireless measurement system for cardiopulmonary activity detection behind a wall. This system generates a continuous wave signal and is used at 2 different frequencies: 2.4 GHz and 10 GHz. The transmitted signal is directed toward the patient's chest situated at 1 m and then reflected. The radar system is based on a vector network analyzer, which measures the phase of S21. The phase variation of S21 contains information about heart and respiration activity. Measurements are carried out every 30 seconds, for a person sitting at a distance of 1 meter, directly in front of the system or behind a wall. Discrete wavelet transform is used as a processing technique to separate heartbeat signal from respiratory signal. The measurements were performed simultaneously with a PC-based electrocardiogram (ECG) which is used as a reference to validate the information extracted from the measured signals.","PeriodicalId":366020,"journal":{"name":"2016 IEEE Middle East Conference on Antennas and Propagation (MECAP)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Feasibility of heartbeat detection behind a wall using CW Doppler radar\",\"authors\":\"S. El-Samad, D. Obeid, G. Zaharia, S. Sadek, G. El Zein\",\"doi\":\"10.1109/MECAP.2016.7790091\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a wireless measurement system for cardiopulmonary activity detection behind a wall. This system generates a continuous wave signal and is used at 2 different frequencies: 2.4 GHz and 10 GHz. The transmitted signal is directed toward the patient's chest situated at 1 m and then reflected. The radar system is based on a vector network analyzer, which measures the phase of S21. The phase variation of S21 contains information about heart and respiration activity. Measurements are carried out every 30 seconds, for a person sitting at a distance of 1 meter, directly in front of the system or behind a wall. Discrete wavelet transform is used as a processing technique to separate heartbeat signal from respiratory signal. The measurements were performed simultaneously with a PC-based electrocardiogram (ECG) which is used as a reference to validate the information extracted from the measured signals.\",\"PeriodicalId\":366020,\"journal\":{\"name\":\"2016 IEEE Middle East Conference on Antennas and Propagation (MECAP)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Middle East Conference on Antennas and Propagation (MECAP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MECAP.2016.7790091\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Middle East Conference on Antennas and Propagation (MECAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECAP.2016.7790091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Feasibility of heartbeat detection behind a wall using CW Doppler radar
This paper presents a wireless measurement system for cardiopulmonary activity detection behind a wall. This system generates a continuous wave signal and is used at 2 different frequencies: 2.4 GHz and 10 GHz. The transmitted signal is directed toward the patient's chest situated at 1 m and then reflected. The radar system is based on a vector network analyzer, which measures the phase of S21. The phase variation of S21 contains information about heart and respiration activity. Measurements are carried out every 30 seconds, for a person sitting at a distance of 1 meter, directly in front of the system or behind a wall. Discrete wavelet transform is used as a processing technique to separate heartbeat signal from respiratory signal. The measurements were performed simultaneously with a PC-based electrocardiogram (ECG) which is used as a reference to validate the information extracted from the measured signals.