Haiyang Liu, Xiaobo Ling, Yifan Zhu, Qiyu Tu, Piao Gao, Chenxu Chao, Yaxin Xie, Xiaodong Zheng, N. Tai
{"title":"分布式光伏配电网备用电源自动交换策略优化","authors":"Haiyang Liu, Xiaobo Ling, Yifan Zhu, Qiyu Tu, Piao Gao, Chenxu Chao, Yaxin Xie, Xiaodong Zheng, N. Tai","doi":"10.1109/ICPSAsia52756.2021.9621550","DOIUrl":null,"url":null,"abstract":"Large-scale distributed photovoltaics (DPs) are connected to the distribution network. when a fault happens in the distribution network, the bus voltage at the fault location cannot immediately decrease to zero due to the existence of DPs, which invalidates the criteria of non-voltage detection and synchronism check and impedes the automatic switching of backup power. Therefore, considering the influence of DPs, this paper puts forward a configuration optimization scheme of backup power automatic switching (BPAS) strategy, which allows the BPAS devices in the distribution network with DPs to conduct non-voltage detection and synchronism check. The example analysis shows that the optimized BPAS strategy can effectively improve the load transfer capacity and reduce the cost of BPAS devices.","PeriodicalId":296085,"journal":{"name":"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)","volume":"72 16","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of Backup Power Automatic Switching Strategy in the Distribution Network with Distributed Photovoltaics\",\"authors\":\"Haiyang Liu, Xiaobo Ling, Yifan Zhu, Qiyu Tu, Piao Gao, Chenxu Chao, Yaxin Xie, Xiaodong Zheng, N. Tai\",\"doi\":\"10.1109/ICPSAsia52756.2021.9621550\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Large-scale distributed photovoltaics (DPs) are connected to the distribution network. when a fault happens in the distribution network, the bus voltage at the fault location cannot immediately decrease to zero due to the existence of DPs, which invalidates the criteria of non-voltage detection and synchronism check and impedes the automatic switching of backup power. Therefore, considering the influence of DPs, this paper puts forward a configuration optimization scheme of backup power automatic switching (BPAS) strategy, which allows the BPAS devices in the distribution network with DPs to conduct non-voltage detection and synchronism check. The example analysis shows that the optimized BPAS strategy can effectively improve the load transfer capacity and reduce the cost of BPAS devices.\",\"PeriodicalId\":296085,\"journal\":{\"name\":\"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)\",\"volume\":\"72 16\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPSAsia52756.2021.9621550\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPSAsia52756.2021.9621550","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimization of Backup Power Automatic Switching Strategy in the Distribution Network with Distributed Photovoltaics
Large-scale distributed photovoltaics (DPs) are connected to the distribution network. when a fault happens in the distribution network, the bus voltage at the fault location cannot immediately decrease to zero due to the existence of DPs, which invalidates the criteria of non-voltage detection and synchronism check and impedes the automatic switching of backup power. Therefore, considering the influence of DPs, this paper puts forward a configuration optimization scheme of backup power automatic switching (BPAS) strategy, which allows the BPAS devices in the distribution network with DPs to conduct non-voltage detection and synchronism check. The example analysis shows that the optimized BPAS strategy can effectively improve the load transfer capacity and reduce the cost of BPAS devices.