S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Mircea
{"title":"抽水蓄能水电站离心泵高效运行的现代分析","authors":"S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Mircea","doi":"10.1109/ATEE58038.2023.10108167","DOIUrl":null,"url":null,"abstract":"In this paper, the authors present a systematized methodology of modelling and analysis of the operating regimes of one of the two main components of pumping units with horizontal shaft - synchronous motor-centrifugal pump assembly - that equips high-power energy pumping stations in hydropower facilities with pumped storage. In this sense, for the centrifugal pumps seen as working machines in electric drive systems, the results obtained following a systematic methodology of modelling and analysis of operating regimes are presented. For solving, algorithms and calculation programs developed in the Mathcad programming environment were designed. For example, a representative case study of one of the three identical double-flow pumps from a high-power energy pumping station from a Hydropower Facility existing in our country (Romania), driven by a horizontal synchronous motor of 6 kV with electromagnetic excitation, was chosen.","PeriodicalId":398894,"journal":{"name":"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modern Aspects of Analysis of the Efficient Operation of the Centrifugal Pumps within the Hydropower Facilities with Pumped Storage\",\"authors\":\"S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Mircea\",\"doi\":\"10.1109/ATEE58038.2023.10108167\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the authors present a systematized methodology of modelling and analysis of the operating regimes of one of the two main components of pumping units with horizontal shaft - synchronous motor-centrifugal pump assembly - that equips high-power energy pumping stations in hydropower facilities with pumped storage. In this sense, for the centrifugal pumps seen as working machines in electric drive systems, the results obtained following a systematic methodology of modelling and analysis of operating regimes are presented. For solving, algorithms and calculation programs developed in the Mathcad programming environment were designed. For example, a representative case study of one of the three identical double-flow pumps from a high-power energy pumping station from a Hydropower Facility existing in our country (Romania), driven by a horizontal synchronous motor of 6 kV with electromagnetic excitation, was chosen.\",\"PeriodicalId\":398894,\"journal\":{\"name\":\"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ATEE58038.2023.10108167\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATEE58038.2023.10108167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modern Aspects of Analysis of the Efficient Operation of the Centrifugal Pumps within the Hydropower Facilities with Pumped Storage
In this paper, the authors present a systematized methodology of modelling and analysis of the operating regimes of one of the two main components of pumping units with horizontal shaft - synchronous motor-centrifugal pump assembly - that equips high-power energy pumping stations in hydropower facilities with pumped storage. In this sense, for the centrifugal pumps seen as working machines in electric drive systems, the results obtained following a systematic methodology of modelling and analysis of operating regimes are presented. For solving, algorithms and calculation programs developed in the Mathcad programming environment were designed. For example, a representative case study of one of the three identical double-flow pumps from a high-power energy pumping station from a Hydropower Facility existing in our country (Romania), driven by a horizontal synchronous motor of 6 kV with electromagnetic excitation, was chosen.