{"title":"一种基于statcom的能抑制次同步谐振的混合并联补偿方案","authors":"F. Mehdizadeh, D. Nazarpour","doi":"10.11591/IJAPE.V6.I3.PP153-162","DOIUrl":null,"url":null,"abstract":"The paper presents the potential use of supplemental control of a new economical phase imbalanced shunt compensation concept for damping Sub Synchronous Resonance (SSR) oscillations. In this scheme, the shunt capacitive compensation in one phase is created by using a single-phase Static Synchronous Compensator (STATCOM) in parallel with a fixed capacitor ( ), and the other two phases are compensated by fixed shunt capacitor (C). The proposed arrangement would, certainly, be economically attractive when compared with a full three-phase STATCOM which have been used/proposed for power swings and SSR damping. SSR mitigation is achieved by introducing a supplemental signal into the control loops of single phase STATCOM. The validity and effectiveness of the proposed structure and supplemental control are demonstrated on a modified version of the IEEE second benchmark model for computer simulation of sub synchronous resonance by means of time domain simulation analysis using the Matlab program. Full Text: PDF DOI: http://dx.doi.org/10.11591/ijape.v6.i3.pp153-162","PeriodicalId":280098,"journal":{"name":"International Journal of Applied Power Engineering","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An STATCOM-Based Hybrid Shunt Compensation Scheme Capable of Damping Subsynchronous Resonance\",\"authors\":\"F. Mehdizadeh, D. Nazarpour\",\"doi\":\"10.11591/IJAPE.V6.I3.PP153-162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the potential use of supplemental control of a new economical phase imbalanced shunt compensation concept for damping Sub Synchronous Resonance (SSR) oscillations. In this scheme, the shunt capacitive compensation in one phase is created by using a single-phase Static Synchronous Compensator (STATCOM) in parallel with a fixed capacitor ( ), and the other two phases are compensated by fixed shunt capacitor (C). The proposed arrangement would, certainly, be economically attractive when compared with a full three-phase STATCOM which have been used/proposed for power swings and SSR damping. SSR mitigation is achieved by introducing a supplemental signal into the control loops of single phase STATCOM. The validity and effectiveness of the proposed structure and supplemental control are demonstrated on a modified version of the IEEE second benchmark model for computer simulation of sub synchronous resonance by means of time domain simulation analysis using the Matlab program. Full Text: PDF DOI: http://dx.doi.org/10.11591/ijape.v6.i3.pp153-162\",\"PeriodicalId\":280098,\"journal\":{\"name\":\"International Journal of Applied Power Engineering\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/IJAPE.V6.I3.PP153-162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/IJAPE.V6.I3.PP153-162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An STATCOM-Based Hybrid Shunt Compensation Scheme Capable of Damping Subsynchronous Resonance
The paper presents the potential use of supplemental control of a new economical phase imbalanced shunt compensation concept for damping Sub Synchronous Resonance (SSR) oscillations. In this scheme, the shunt capacitive compensation in one phase is created by using a single-phase Static Synchronous Compensator (STATCOM) in parallel with a fixed capacitor ( ), and the other two phases are compensated by fixed shunt capacitor (C). The proposed arrangement would, certainly, be economically attractive when compared with a full three-phase STATCOM which have been used/proposed for power swings and SSR damping. SSR mitigation is achieved by introducing a supplemental signal into the control loops of single phase STATCOM. The validity and effectiveness of the proposed structure and supplemental control are demonstrated on a modified version of the IEEE second benchmark model for computer simulation of sub synchronous resonance by means of time domain simulation analysis using the Matlab program. Full Text: PDF DOI: http://dx.doi.org/10.11591/ijape.v6.i3.pp153-162