{"title":"牵引传动一种新的过调制策略","authors":"Bonho Bae, Sang-Hoon Kim, S. Sul","doi":"10.1109/APEC.1999.749719","DOIUrl":null,"url":null,"abstract":"This paper proposes a new overmodulation strategy to give a better voltage utilization by tracking the voltage vector along the hexagon sides of traction motor drives. This strategy enables the inverter to control both the magnitude and angle of current. Therefore, vector control using this strategy can lead to better output torque dynamics compared to the conventional slip frequency control with six-step voltage, which is widely used in traction drives. In this strategy, the d-axis output voltage of a current controller to control the flux is conserved and the q-axis output voltage to control the torque is controlled to place the voltage vector on the hexagon boundary in case of overmodulation. The limited q-axis voltage is used for anti-windup of q-axis current controller. This paper also presents a new field weakening scheme which incorporates the proposed overmodulation strategy. In this scheme, the flux level is selected by both required current limit and the available maximum voltage along hexagon sides. The validity of the proposed overall scheme is confirmed by computer simulation and experiments with a prototype setup.","PeriodicalId":287192,"journal":{"name":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A new overmodulation strategy for traction drive\",\"authors\":\"Bonho Bae, Sang-Hoon Kim, S. Sul\",\"doi\":\"10.1109/APEC.1999.749719\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a new overmodulation strategy to give a better voltage utilization by tracking the voltage vector along the hexagon sides of traction motor drives. This strategy enables the inverter to control both the magnitude and angle of current. Therefore, vector control using this strategy can lead to better output torque dynamics compared to the conventional slip frequency control with six-step voltage, which is widely used in traction drives. In this strategy, the d-axis output voltage of a current controller to control the flux is conserved and the q-axis output voltage to control the torque is controlled to place the voltage vector on the hexagon boundary in case of overmodulation. The limited q-axis voltage is used for anti-windup of q-axis current controller. This paper also presents a new field weakening scheme which incorporates the proposed overmodulation strategy. In this scheme, the flux level is selected by both required current limit and the available maximum voltage along hexagon sides. The validity of the proposed overall scheme is confirmed by computer simulation and experiments with a prototype setup.\",\"PeriodicalId\":287192,\"journal\":{\"name\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1999.749719\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1999.749719","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文提出了一种新的过调制策略,通过跟踪牵引电机驱动器六边形侧的电压矢量来更好地利用电压。这种策略使逆变器能够控制电流的大小和角度。因此,与广泛应用于牵引传动的六步电压转差频率控制相比,采用该策略的矢量控制可以获得更好的输出转矩动态特性。在该策略中,控制磁通的电流控制器的d轴输出电压保持不变,控制转矩的q轴输出电压,在过调制情况下将电压矢量置于六边形边界上。限定q轴电压用于q轴电流控制器的防绕组。本文还提出了一种结合上述过调制策略的新型弱场方案。在该方案中,磁通水平是根据所需的电流限制和沿六边形边的可用最大电压来选择的。通过计算机仿真和样机实验验证了该方案的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new overmodulation strategy for traction drive
This paper proposes a new overmodulation strategy to give a better voltage utilization by tracking the voltage vector along the hexagon sides of traction motor drives. This strategy enables the inverter to control both the magnitude and angle of current. Therefore, vector control using this strategy can lead to better output torque dynamics compared to the conventional slip frequency control with six-step voltage, which is widely used in traction drives. In this strategy, the d-axis output voltage of a current controller to control the flux is conserved and the q-axis output voltage to control the torque is controlled to place the voltage vector on the hexagon boundary in case of overmodulation. The limited q-axis voltage is used for anti-windup of q-axis current controller. This paper also presents a new field weakening scheme which incorporates the proposed overmodulation strategy. In this scheme, the flux level is selected by both required current limit and the available maximum voltage along hexagon sides. The validity of the proposed overall scheme is confirmed by computer simulation and experiments with a prototype setup.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A zero voltage switching and self-reset forward converter topology A method of speed sensorless control of direct-field-oriented induction motor operating at high efficiency with core loss consideration Robust flux weakening scheme for surface-mounted permanent-magnet synchronous drives employing an adaptive lattice-structure filter A new control method for single-phase active power line conditioners A comprehensive study of neutral-point voltage balancing problem in three-level neutral-point-clamped voltage source PWM inverters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1