A. Kosorukov, P. Tukeev, Svetlana Pashicheva, V. Titkov, N. Kutuzova, P. Toman
{"title":"介绍了电涌保护装置对空绝缘高压变电站低压系统防雷的特点","authors":"A. Kosorukov, P. Tukeev, Svetlana Pashicheva, V. Titkov, N. Kutuzova, P. Toman","doi":"10.1109/EPE51172.2020.9269273","DOIUrl":null,"url":null,"abstract":"The present paper deals with applying of surge protective devices (SPD) for protection of air-insulated substation's low voltage networks. Key point in application of SPD in substation low-voltage networks is the estimation of lightning current distribution between the different communications of the object of interest. The measurement and calculation results of pulse current distribution between grounding and cable line at limitation of lightning strike in searchlight tower, combined with lightning rod, had been presented. Real-life field measurements have been conducted on training range of “Lenenergo” JSC. Value estimation of lightning current, flowing through SPD, installed on a light control switchboard, is given. The requirements for pulse current amplitude of SPDs have been defined. The general approaches to organizing substation light network protection from pulse overvoltage had been described.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The features of lightning protection of low-voltage system of Air insulated High Voltage Substation by surge protective device\",\"authors\":\"A. Kosorukov, P. Tukeev, Svetlana Pashicheva, V. Titkov, N. Kutuzova, P. Toman\",\"doi\":\"10.1109/EPE51172.2020.9269273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present paper deals with applying of surge protective devices (SPD) for protection of air-insulated substation's low voltage networks. Key point in application of SPD in substation low-voltage networks is the estimation of lightning current distribution between the different communications of the object of interest. The measurement and calculation results of pulse current distribution between grounding and cable line at limitation of lightning strike in searchlight tower, combined with lightning rod, had been presented. Real-life field measurements have been conducted on training range of “Lenenergo” JSC. Value estimation of lightning current, flowing through SPD, installed on a light control switchboard, is given. The requirements for pulse current amplitude of SPDs have been defined. The general approaches to organizing substation light network protection from pulse overvoltage had been described.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269273\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269273","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The features of lightning protection of low-voltage system of Air insulated High Voltage Substation by surge protective device
The present paper deals with applying of surge protective devices (SPD) for protection of air-insulated substation's low voltage networks. Key point in application of SPD in substation low-voltage networks is the estimation of lightning current distribution between the different communications of the object of interest. The measurement and calculation results of pulse current distribution between grounding and cable line at limitation of lightning strike in searchlight tower, combined with lightning rod, had been presented. Real-life field measurements have been conducted on training range of “Lenenergo” JSC. Value estimation of lightning current, flowing through SPD, installed on a light control switchboard, is given. The requirements for pulse current amplitude of SPDs have been defined. The general approaches to organizing substation light network protection from pulse overvoltage had been described.