用声发射特征对变压器绝缘初期放电进行分类

G. Koperundevi, M. Goyal, Sunil C. Das, N. K. Roy, R. Sarathi
{"title":"用声发射特征对变压器绝缘初期放电进行分类","authors":"G. Koperundevi, M. Goyal, Sunil C. Das, N. K. Roy, R. Sarathi","doi":"10.1109/INDCON.2010.5712640","DOIUrl":null,"url":null,"abstract":"One of the major causes of failure of converter transformer is the incipient discharges caused due to deterioration of insulation. The insulation in the converter transformers is stressed not only by AC voltages but also with remnant DC voltages. The Acoustic Emission (AE) Technique can identify such incipient discharges in the converter transformer. In the present work, experimental studies were carried out by simulating various incipient discharges such as corona discharge, partial discharge (PD) and surface discharge in an insulation test cell under AC and DC voltages by using AE Technique. The bandwidth of the AE sensor used in the present study is of wide band type and the bandwidth lies in the range of 100 kHz-1 MHz. It is observed that AE signals produced due to different incipient discharges are having different dominant frequency range, amplitude, rise time, number of pulses and energy. To classify the discharges an innovative methodology is adopted by constructing the ternary plot from the FFT output of AE signal generated by the incipient discharges.","PeriodicalId":109071,"journal":{"name":"2010 Annual IEEE India Conference (INDICON)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Classification of incipient discharges in transformer insulation using Acoustic Emission signatures\",\"authors\":\"G. Koperundevi, M. Goyal, Sunil C. Das, N. K. Roy, R. Sarathi\",\"doi\":\"10.1109/INDCON.2010.5712640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the major causes of failure of converter transformer is the incipient discharges caused due to deterioration of insulation. The insulation in the converter transformers is stressed not only by AC voltages but also with remnant DC voltages. The Acoustic Emission (AE) Technique can identify such incipient discharges in the converter transformer. In the present work, experimental studies were carried out by simulating various incipient discharges such as corona discharge, partial discharge (PD) and surface discharge in an insulation test cell under AC and DC voltages by using AE Technique. The bandwidth of the AE sensor used in the present study is of wide band type and the bandwidth lies in the range of 100 kHz-1 MHz. It is observed that AE signals produced due to different incipient discharges are having different dominant frequency range, amplitude, rise time, number of pulses and energy. To classify the discharges an innovative methodology is adopted by constructing the ternary plot from the FFT output of AE signal generated by the incipient discharges.\",\"PeriodicalId\":109071,\"journal\":{\"name\":\"2010 Annual IEEE India Conference (INDICON)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 Annual IEEE India Conference (INDICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INDCON.2010.5712640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 Annual IEEE India Conference (INDICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDCON.2010.5712640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

换流变压器故障的主要原因之一是由于绝缘劣化引起的初期放电。换流变压器的绝缘不仅会受到交流电压的影响,还会受到残余直流电压的影响。声发射(AE)技术可以识别换流变压器的初期放电。本文利用声发射技术,在交流和直流电压下,模拟了绝缘试验槽内的电晕放电、局部放电和表面放电等各种初期放电现象。本研究中使用的声发射传感器带宽为宽带型,带宽在100 kHz-1 MHz范围内。观察到,不同初始放电产生的声发射信号具有不同的主导频率范围、幅值、上升时间、脉冲数和能量。为了对放电进行分类,采用了一种创新的方法,即从早期放电产生的声发射信号的FFT输出中构造三元图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Classification of incipient discharges in transformer insulation using Acoustic Emission signatures
One of the major causes of failure of converter transformer is the incipient discharges caused due to deterioration of insulation. The insulation in the converter transformers is stressed not only by AC voltages but also with remnant DC voltages. The Acoustic Emission (AE) Technique can identify such incipient discharges in the converter transformer. In the present work, experimental studies were carried out by simulating various incipient discharges such as corona discharge, partial discharge (PD) and surface discharge in an insulation test cell under AC and DC voltages by using AE Technique. The bandwidth of the AE sensor used in the present study is of wide band type and the bandwidth lies in the range of 100 kHz-1 MHz. It is observed that AE signals produced due to different incipient discharges are having different dominant frequency range, amplitude, rise time, number of pulses and energy. To classify the discharges an innovative methodology is adopted by constructing the ternary plot from the FFT output of AE signal generated by the incipient discharges.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An efficient technique for protein classification using feature extraction by artificial neural networks Coordinated design of excitation and TCSC-based stabilizers for multimachine power system Estimation of the resonant frequency and magnetic polarizability of an edge coupled circular split ring resonator with rotated outer ring Realization of ultra wideband bandpass filter using new type of split-ring Defected Ground Structure Double-Pole Four-Throw RF CMOS switch design with double-gate transistors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1