{"title":"低压配电网的电压保护与谐波消除","authors":"Prof. Amruta Bijwar, Prof. Madhuri Zambre","doi":"10.17762/ijnpme.v7i04.68","DOIUrl":null,"url":null,"abstract":"Nowadays low voltage distribution network is considered as worldwide future generation distribution network. But the major concern is harmonics generation and steps taken to cancel those harmonics. In our proposed work, low voltage distribution network is designed with low voltage and harmonics are cancelled in our method. The combination of current control unit and voltage control unit will give extra reliable power solution to increase the required capacity of low voltage grids. The high voltage protection gears are used in worst environment for low voltage and low current distribution network test is preferable to assess a variety of operation uniqueness. Therefore, it has few restrictions in implementation of economic in addition to process methodologies. In our work a 48V direct current base up-scale low voltage distribution network test is urbanized to allow the copy and surveillance of a variety of phenomenon of direct current distribution networks. The proposed system provide stretchy pattern ability by introduce S-connectors and T-connectors module that will be proscribed distantly, and near real time monitor function through by means of a data acquisition system associated toward the nodes. Each connector be able to calculate Power, Voltage and current with up to 250 kHz frequency. To calculate power quality and to understand the performance of the distribution network, frequency analysis is required along with collected data.","PeriodicalId":297822,"journal":{"name":"International Journal of New Practices in Management and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Voltage Protection and Harmonics Cancellation in Low Voltage Distribution Network\",\"authors\":\"Prof. Amruta Bijwar, Prof. Madhuri Zambre\",\"doi\":\"10.17762/ijnpme.v7i04.68\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays low voltage distribution network is considered as worldwide future generation distribution network. But the major concern is harmonics generation and steps taken to cancel those harmonics. In our proposed work, low voltage distribution network is designed with low voltage and harmonics are cancelled in our method. The combination of current control unit and voltage control unit will give extra reliable power solution to increase the required capacity of low voltage grids. The high voltage protection gears are used in worst environment for low voltage and low current distribution network test is preferable to assess a variety of operation uniqueness. Therefore, it has few restrictions in implementation of economic in addition to process methodologies. In our work a 48V direct current base up-scale low voltage distribution network test is urbanized to allow the copy and surveillance of a variety of phenomenon of direct current distribution networks. The proposed system provide stretchy pattern ability by introduce S-connectors and T-connectors module that will be proscribed distantly, and near real time monitor function through by means of a data acquisition system associated toward the nodes. Each connector be able to calculate Power, Voltage and current with up to 250 kHz frequency. To calculate power quality and to understand the performance of the distribution network, frequency analysis is required along with collected data.\",\"PeriodicalId\":297822,\"journal\":{\"name\":\"International Journal of New Practices in Management and Engineering\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of New Practices in Management and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17762/ijnpme.v7i04.68\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of New Practices in Management and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17762/ijnpme.v7i04.68","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage Protection and Harmonics Cancellation in Low Voltage Distribution Network
Nowadays low voltage distribution network is considered as worldwide future generation distribution network. But the major concern is harmonics generation and steps taken to cancel those harmonics. In our proposed work, low voltage distribution network is designed with low voltage and harmonics are cancelled in our method. The combination of current control unit and voltage control unit will give extra reliable power solution to increase the required capacity of low voltage grids. The high voltage protection gears are used in worst environment for low voltage and low current distribution network test is preferable to assess a variety of operation uniqueness. Therefore, it has few restrictions in implementation of economic in addition to process methodologies. In our work a 48V direct current base up-scale low voltage distribution network test is urbanized to allow the copy and surveillance of a variety of phenomenon of direct current distribution networks. The proposed system provide stretchy pattern ability by introduce S-connectors and T-connectors module that will be proscribed distantly, and near real time monitor function through by means of a data acquisition system associated toward the nodes. Each connector be able to calculate Power, Voltage and current with up to 250 kHz frequency. To calculate power quality and to understand the performance of the distribution network, frequency analysis is required along with collected data.