Fenton氧化法纺织湿法工业废水对氯酚顺应性监测

IF 1.3 Q4 ENGINEERING, ENVIRONMENTAL Journal of Ecological Engineering Pub Date : 2023-11-01 DOI:10.12911/22998993/171370
Muhammad Owais, Asad A. Zaidi, Abdul Hameed Memon, Ahmad Hussain, Arsalan Ahmed
{"title":"Fenton氧化法纺织湿法工业废水对氯酚顺应性监测","authors":"Muhammad Owais, Asad A. Zaidi, Abdul Hameed Memon, Ahmad Hussain, Arsalan Ahmed","doi":"10.12911/22998993/171370","DOIUrl":null,"url":null,"abstract":"The textile industries utilize number of dyes, chemicals, and other materials to suffuse the characteristic of fabric qualities. A huge quantity of effluents is produced during the process. However, toxicity from synthetic dyes has become a cause of severe environment concern. Chlorophenols are mostly present in synthetic dyes which are proven carcinogenic and therefore undesirable. A number of techniques were used to remove p-Chlorophenol up to the ZDHC MRSL limit. However, none of them found to be up to mark. Fenton oxidation process was selected for its suitability to degrade the p-Chlorophenol up to 5 ppm or less from the textile wet processing industry effluent. In the present study cotton fiber was selected, as medium considering its common use in textile industry. The impact of Ferrous ion (Fe +2 ), Hydrogen peroxide (H 2 O 2 ) and pH on the removal of p-Chlorophenol was examined. The Box-Behnken Design (BBD) of (RSM) was employed to achieve optimum desirable condition for the removal of p-Chlorophenol from effluent. A quadratic model is suggested to relate the independent variables for maximum removal of p-Chlorophenol at the optimal process condition. Results suggest that removal efficiency under the optimum condition [Fe +2 ] = 6.5×10 -3 M, [H 2 O 2 ] = 2.9×10 -2 M, and [pH] = 3.5 was >90% in 15 minutes. It can be summarized that Fenton oxidation process as the promising potential for removal of p-Chlorophenol from textile wet processing industry effluent. This research work helps to address for the general knowledge gap in the textile wet processing industry effluent treatment and provide a plate form for further research.","PeriodicalId":15652,"journal":{"name":"Journal of Ecological Engineering","volume":"358 1","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assay of p-Chlorophenol Compliance Monitoring in Textile Wet Processing Industry Effluent Using Fenton Oxidation Process\",\"authors\":\"Muhammad Owais, Asad A. Zaidi, Abdul Hameed Memon, Ahmad Hussain, Arsalan Ahmed\",\"doi\":\"10.12911/22998993/171370\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The textile industries utilize number of dyes, chemicals, and other materials to suffuse the characteristic of fabric qualities. A huge quantity of effluents is produced during the process. However, toxicity from synthetic dyes has become a cause of severe environment concern. Chlorophenols are mostly present in synthetic dyes which are proven carcinogenic and therefore undesirable. A number of techniques were used to remove p-Chlorophenol up to the ZDHC MRSL limit. However, none of them found to be up to mark. Fenton oxidation process was selected for its suitability to degrade the p-Chlorophenol up to 5 ppm or less from the textile wet processing industry effluent. In the present study cotton fiber was selected, as medium considering its common use in textile industry. The impact of Ferrous ion (Fe +2 ), Hydrogen peroxide (H 2 O 2 ) and pH on the removal of p-Chlorophenol was examined. The Box-Behnken Design (BBD) of (RSM) was employed to achieve optimum desirable condition for the removal of p-Chlorophenol from effluent. A quadratic model is suggested to relate the independent variables for maximum removal of p-Chlorophenol at the optimal process condition. Results suggest that removal efficiency under the optimum condition [Fe +2 ] = 6.5×10 -3 M, [H 2 O 2 ] = 2.9×10 -2 M, and [pH] = 3.5 was >90% in 15 minutes. It can be summarized that Fenton oxidation process as the promising potential for removal of p-Chlorophenol from textile wet processing industry effluent. This research work helps to address for the general knowledge gap in the textile wet processing industry effluent treatment and provide a plate form for further research.\",\"PeriodicalId\":15652,\"journal\":{\"name\":\"Journal of Ecological Engineering\",\"volume\":\"358 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ecological Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12911/22998993/171370\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ecological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12911/22998993/171370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assay of p-Chlorophenol Compliance Monitoring in Textile Wet Processing Industry Effluent Using Fenton Oxidation Process
The textile industries utilize number of dyes, chemicals, and other materials to suffuse the characteristic of fabric qualities. A huge quantity of effluents is produced during the process. However, toxicity from synthetic dyes has become a cause of severe environment concern. Chlorophenols are mostly present in synthetic dyes which are proven carcinogenic and therefore undesirable. A number of techniques were used to remove p-Chlorophenol up to the ZDHC MRSL limit. However, none of them found to be up to mark. Fenton oxidation process was selected for its suitability to degrade the p-Chlorophenol up to 5 ppm or less from the textile wet processing industry effluent. In the present study cotton fiber was selected, as medium considering its common use in textile industry. The impact of Ferrous ion (Fe +2 ), Hydrogen peroxide (H 2 O 2 ) and pH on the removal of p-Chlorophenol was examined. The Box-Behnken Design (BBD) of (RSM) was employed to achieve optimum desirable condition for the removal of p-Chlorophenol from effluent. A quadratic model is suggested to relate the independent variables for maximum removal of p-Chlorophenol at the optimal process condition. Results suggest that removal efficiency under the optimum condition [Fe +2 ] = 6.5×10 -3 M, [H 2 O 2 ] = 2.9×10 -2 M, and [pH] = 3.5 was >90% in 15 minutes. It can be summarized that Fenton oxidation process as the promising potential for removal of p-Chlorophenol from textile wet processing industry effluent. This research work helps to address for the general knowledge gap in the textile wet processing industry effluent treatment and provide a plate form for further research.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ecological Engineering
Journal of Ecological Engineering ENGINEERING, ENVIRONMENTAL-
CiteScore
2.60
自引率
15.40%
发文量
379
审稿时长
8 weeks
期刊介绍: - Industrial and municipal waste management - Pro-ecological technologies and products - Energy-saving technologies - Environmental landscaping - Environmental monitoring - Climate change in the environment - Sustainable development - Processing and usage of mineral resources - Recovery of valuable materials and fuels - Surface water and groundwater management - Water and wastewater treatment - Smog and air pollution prevention - Protection and reclamation of soils - Reclamation and revitalization of degraded areas - Heavy metals in the environment - Renewable energy technologies - Environmental protection of rural areas - Restoration and protection of urban environment - Prevention of noise in the environment - Environmental life-cycle assessment (LCA) - Simulations and computer modeling for the environment
期刊最新文献
Indoor Air Quality in Schools Located in Poland, Lublin Province Estimation of Photovoltaic Module Performance with L-Shaped Aluminum Fins Using Weather Data Determination of the Composition of Wastewater from Individual Processes of Leather Tanning Production in a Small Plant Incidence of the Leachates from the Quevedo Emerging Cell on the Water Quality of the Limón Stream, San Cristóbal Parish, Quevedo Canton Reducing Tannery Wastewater Pollutants through a Magnetic-Field and Ozone-Treatment Electrocoagulation System using Response Surface Methodology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1