负载Cu(II)碳材料制备牛磺酸检测伏安传感器

IF 1.3 4区 化学 Q3 CHEMISTRY, MULTIDISCIPLINARY Bulletin of the Chemical Society of Ethiopia Pub Date : 2023-09-19 DOI:10.4314/bcse.v37i6.20
Fatma Bilge Emre
{"title":"负载Cu(II)碳材料制备牛磺酸检测伏安传感器","authors":"Fatma Bilge Emre","doi":"10.4314/bcse.v37i6.20","DOIUrl":null,"url":null,"abstract":"ABSTRACT. In this study, for the detection of taurine in philological fluids, modified electrodes were prepared from glassy carbon electrodes with MWCNT (multi-wall carbon nanotube) + Cu(NO3)2 + carbon-based material. A carbon-based material was obtained by carbonization of Pinus sylvestris branch needles (CPS). Cu(NO3)2 and MWCNT structure (Cu(NO3)2/MWCNT) were added to the carbon-based material and the obtained mixture was used in the modification of the glassy carbon electrode surface. The surface morphology and structure of the prepared electrodes were characterized by electron microscopy scanning (SEM) and atomic force microscopy (AFM). Taurine detection with a modified electrode was made by cyclic voltammetry (CV) in 0.1 M KCl (vs. Ag/AgCl). The calibration curve of the modified electrode for taurine in the 10-150 µM range showed a linear response, and R2 value was 0.976. Limit of detection (LOD) and limit of quantification (LOQ) of the modified electrode were found 19 µM and 9.75 µM, respectively. The application of the electrode as a chemical sensor was carried out with commercially available energy drink samples. Satisfactory results have been obtained from the samples. The sensor can be used for routine taurine analysis. This electrode can quickly determine the amount of taurine in real samples with 90% accuracy in two minutes.
 KEY WORDS: Taurine detection, Modified electrode, MWCNT, Sensor, Cyclic voltammetry
 Bull. Chem. Soc. Ethiop. 2023, 37(6), 1565-1576. DOI: https://dx.doi.org/10.4314/bcse.v37i6.20","PeriodicalId":9501,"journal":{"name":"Bulletin of the Chemical Society of Ethiopia","volume":"184 1","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preparation of voltammetric sensors for taurine detection from Cu(II)-loaded carbon materials\",\"authors\":\"Fatma Bilge Emre\",\"doi\":\"10.4314/bcse.v37i6.20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT. In this study, for the detection of taurine in philological fluids, modified electrodes were prepared from glassy carbon electrodes with MWCNT (multi-wall carbon nanotube) + Cu(NO3)2 + carbon-based material. A carbon-based material was obtained by carbonization of Pinus sylvestris branch needles (CPS). Cu(NO3)2 and MWCNT structure (Cu(NO3)2/MWCNT) were added to the carbon-based material and the obtained mixture was used in the modification of the glassy carbon electrode surface. The surface morphology and structure of the prepared electrodes were characterized by electron microscopy scanning (SEM) and atomic force microscopy (AFM). Taurine detection with a modified electrode was made by cyclic voltammetry (CV) in 0.1 M KCl (vs. Ag/AgCl). The calibration curve of the modified electrode for taurine in the 10-150 µM range showed a linear response, and R2 value was 0.976. Limit of detection (LOD) and limit of quantification (LOQ) of the modified electrode were found 19 µM and 9.75 µM, respectively. The application of the electrode as a chemical sensor was carried out with commercially available energy drink samples. Satisfactory results have been obtained from the samples. The sensor can be used for routine taurine analysis. This electrode can quickly determine the amount of taurine in real samples with 90% accuracy in two minutes.
 KEY WORDS: Taurine detection, Modified electrode, MWCNT, Sensor, Cyclic voltammetry
 Bull. Chem. Soc. Ethiop. 2023, 37(6), 1565-1576. DOI: https://dx.doi.org/10.4314/bcse.v37i6.20\",\"PeriodicalId\":9501,\"journal\":{\"name\":\"Bulletin of the Chemical Society of Ethiopia\",\"volume\":\"184 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the Chemical Society of Ethiopia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/bcse.v37i6.20\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Chemical Society of Ethiopia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/bcse.v37i6.20","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

摘要本研究以MWCNT(多壁碳纳米管)+ Cu(NO3)2 +碳基材料为电极,制备了修饰电极,用于检测语言流体中的牛磺酸。以松针为原料,进行炭化制备碳基材料。在碳基材料中加入Cu(NO3)2和MWCNT结构(Cu(NO3)2/MWCNT),并将所得混合物用于玻碳电极表面改性。利用电子显微镜(SEM)和原子力显微镜(AFM)对制备电极的表面形貌和结构进行了表征。采用0.1 M KCl (vs. Ag/AgCl)循环伏安法(CV)对改进电极进行牛磺酸检测。改良电极对牛磺酸在10 ~ 150µM范围内的校准曲线呈线性响应,R2值为0.976。修饰电极的检测限(LOD)和定量限(LOQ)分别为19µM和9.75µM。将该电极作为化学传感器应用于市售能量饮料样品中。样品得到了满意的结果。该传感器可用于常规牛磺酸分析。该电极可在两分钟内快速测定实际样品中牛磺酸的含量,准确度达90%。 关键词:牛磺酸检测,修饰电极,MWCNT,传感器,循环伏安法;公牛。化学。Soc。中国生物医学工程学报,2016,37(6):1565-1576。DOI: https://dx.doi.org/10.4314/bcse.v37i6.20
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Preparation of voltammetric sensors for taurine detection from Cu(II)-loaded carbon materials
ABSTRACT. In this study, for the detection of taurine in philological fluids, modified electrodes were prepared from glassy carbon electrodes with MWCNT (multi-wall carbon nanotube) + Cu(NO3)2 + carbon-based material. A carbon-based material was obtained by carbonization of Pinus sylvestris branch needles (CPS). Cu(NO3)2 and MWCNT structure (Cu(NO3)2/MWCNT) were added to the carbon-based material and the obtained mixture was used in the modification of the glassy carbon electrode surface. The surface morphology and structure of the prepared electrodes were characterized by electron microscopy scanning (SEM) and atomic force microscopy (AFM). Taurine detection with a modified electrode was made by cyclic voltammetry (CV) in 0.1 M KCl (vs. Ag/AgCl). The calibration curve of the modified electrode for taurine in the 10-150 µM range showed a linear response, and R2 value was 0.976. Limit of detection (LOD) and limit of quantification (LOQ) of the modified electrode were found 19 µM and 9.75 µM, respectively. The application of the electrode as a chemical sensor was carried out with commercially available energy drink samples. Satisfactory results have been obtained from the samples. The sensor can be used for routine taurine analysis. This electrode can quickly determine the amount of taurine in real samples with 90% accuracy in two minutes. KEY WORDS: Taurine detection, Modified electrode, MWCNT, Sensor, Cyclic voltammetry Bull. Chem. Soc. Ethiop. 2023, 37(6), 1565-1576. DOI: https://dx.doi.org/10.4314/bcse.v37i6.20
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
8.30%
发文量
113
审稿时长
6-12 weeks
期刊介绍: The Bulletin of the Chemical Society of Ethiopia (BCSE) is a triannual publication of the Chemical Society of Ethiopia. The BCSE is an open access and peer reviewed journal. The BCSE invites contributions in any field of basic and applied chemistry.
期刊最新文献
Chemical composition, antibacterial and antioxidant activities of essential oils from Ccyphostemma adenocaule and Ziziphus spinachristi Synthesis and characterization of activated carbon from Asphodelus microcarpus in two steps A selective dispersive liquid-liquid micro-extraction technique for trace level pollutants enrichment of pharmaceutical residues from hospital wastewaters followed by liquid chromatographic analysis Synthesis, crystal structure, DFT calculation and Hirshfeld surface analysis of N-(4-methyl phenyl)-2-(3-nitro-benzamido) benzamide Assembly of two luminescent cadmium(II) 4,4'-phosphini Co-dibenzoate coordination polymers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1