{"title":"气相色谱法同时定量检测草本清新凝胶牙膏中的六种调味剂","authors":"Sumit Tiwari, Vishal Sareen, Yamini Sharma, Neha Sindhi, Prasun Bandyopadhyay, Ranjan Mitra","doi":"10.1002/ffj.3767","DOIUrl":null,"url":null,"abstract":"<p>There are many methods reported to identify and quantify volatile compounds. Many of them are based on chromatographic techniques, such as high-performance liquid chromatography (HPLC), gas chromatography with flame ionization detector (GC-FID), and GC coupled with mass spectrometry (GC–MS). But among all GC-FID and GC–MS are majorly used for the detection and quantification of volatile compounds. A new gas chromatographic method has been developed for simultaneous determination of six flavouring agents [menthol, benzyl alcohol, methyl salicylate, anethole, menthol carboxamide (WS-3) and eugenol] in herbal freshness gel toothpaste. All six flavours were separated using a DB-WAX (Agilent) capillary GC column (30 m × 0.25 mm × 0.25 μm) and flame ionization detector (FID). This method was validated for various parameters such as precision, linearity, accuracy, stability, robustness, limit of detection, and limit of quantification as per ICH guidelines, AOAC internationals Appendix K. All the validation parameters were found to be within acceptable limits. The method was successfully applied for the quantification of all flavouring agents in toothpaste formulations.</p>","PeriodicalId":170,"journal":{"name":"Flavour and Fragrance Journal","volume":"39 1","pages":"69-79"},"PeriodicalIF":2.1000,"publicationDate":"2023-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous quantification of six flavouring agents in herbal freshness gel toothpaste by gas chromatography\",\"authors\":\"Sumit Tiwari, Vishal Sareen, Yamini Sharma, Neha Sindhi, Prasun Bandyopadhyay, Ranjan Mitra\",\"doi\":\"10.1002/ffj.3767\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>There are many methods reported to identify and quantify volatile compounds. Many of them are based on chromatographic techniques, such as high-performance liquid chromatography (HPLC), gas chromatography with flame ionization detector (GC-FID), and GC coupled with mass spectrometry (GC–MS). But among all GC-FID and GC–MS are majorly used for the detection and quantification of volatile compounds. A new gas chromatographic method has been developed for simultaneous determination of six flavouring agents [menthol, benzyl alcohol, methyl salicylate, anethole, menthol carboxamide (WS-3) and eugenol] in herbal freshness gel toothpaste. All six flavours were separated using a DB-WAX (Agilent) capillary GC column (30 m × 0.25 mm × 0.25 μm) and flame ionization detector (FID). This method was validated for various parameters such as precision, linearity, accuracy, stability, robustness, limit of detection, and limit of quantification as per ICH guidelines, AOAC internationals Appendix K. All the validation parameters were found to be within acceptable limits. The method was successfully applied for the quantification of all flavouring agents in toothpaste formulations.</p>\",\"PeriodicalId\":170,\"journal\":{\"name\":\"Flavour and Fragrance Journal\",\"volume\":\"39 1\",\"pages\":\"69-79\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Flavour and Fragrance Journal\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ffj.3767\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flavour and Fragrance Journal","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ffj.3767","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 0
摘要
有许多方法报道鉴定和量化挥发性化合物。其中许多是基于色谱技术,如高效液相色谱(HPLC),气相色谱与火焰电离检测器(GC- fid),气相色谱与质谱联用(GC- ms)。但其中GC-FID和GC-MS主要用于挥发性化合物的检测和定量。采用气相色谱法同时测定草药新鲜凝胶牙膏中薄荷醇、苄醇、水杨酸甲酯、茴香脑、薄荷醇羧酰胺(WS-3)和丁香酚6种调味剂的含量。采用DB-WAX (Agilent)毛细管气相色谱柱(30 m × 0.25 mm × 0.25 μm)和火焰电离检测器(FID)对6种风味进行分离。根据ICH指南、AOAC国际附录k对该方法的精密度、线性度、准确度、稳定性、鲁棒性、检出限、定量限等参数进行了验证。所有验证参数均在可接受范围内。该方法可用于牙膏配方中各种调味剂的定量分析。
Simultaneous quantification of six flavouring agents in herbal freshness gel toothpaste by gas chromatography
There are many methods reported to identify and quantify volatile compounds. Many of them are based on chromatographic techniques, such as high-performance liquid chromatography (HPLC), gas chromatography with flame ionization detector (GC-FID), and GC coupled with mass spectrometry (GC–MS). But among all GC-FID and GC–MS are majorly used for the detection and quantification of volatile compounds. A new gas chromatographic method has been developed for simultaneous determination of six flavouring agents [menthol, benzyl alcohol, methyl salicylate, anethole, menthol carboxamide (WS-3) and eugenol] in herbal freshness gel toothpaste. All six flavours were separated using a DB-WAX (Agilent) capillary GC column (30 m × 0.25 mm × 0.25 μm) and flame ionization detector (FID). This method was validated for various parameters such as precision, linearity, accuracy, stability, robustness, limit of detection, and limit of quantification as per ICH guidelines, AOAC internationals Appendix K. All the validation parameters were found to be within acceptable limits. The method was successfully applied for the quantification of all flavouring agents in toothpaste formulations.
期刊介绍:
Flavour and Fragrance Journal publishes original research articles, reviews and special reports on all aspects of flavour and fragrance. Its high scientific standards and international character is ensured by a strict refereeing system and an editorial team representing the multidisciplinary expertise of our field of research. Because analysis is the matter of many submissions and supports the data used in many other domains, a special attention is placed on the quality of analytical techniques. All natural or synthetic products eliciting or influencing a sensory stimulus related to gustation or olfaction are eligible for publication in the Journal. Eligible as well are the techniques related to their preparation, characterization and safety. This notably involves analytical and sensory analysis, physical chemistry, modeling, microbiology – antimicrobial properties, biology, chemosensory perception and legislation.
The overall aim is to produce a journal of the highest quality which provides a scientific forum for academia as well as for industry on all aspects of flavors, fragrances and related materials, and which is valued by readers and contributors alike.