使用多普勒雷达的独立式便携式呼吸速率监测仪的研制

IF 0.5 4区 工程技术 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Electronics and Communications in Japan Pub Date : 2023-10-09 DOI:10.1002/ecj.12427
Miyu Katoh, Takeru Kanazawa, Yoshifusa Abe, Guanghao Sun, Takemi Matsui
{"title":"使用多普勒雷达的独立式便携式呼吸速率监测仪的研制","authors":"Miyu Katoh,&nbsp;Takeru Kanazawa,&nbsp;Yoshifusa Abe,&nbsp;Guanghao Sun,&nbsp;Takemi Matsui","doi":"10.1002/ecj.12427","DOIUrl":null,"url":null,"abstract":"<p>Respiratory rate (RR) is known to be a more accurate predictor of clinical deterioration than other vital signs. However, there were few respiration measurement devices certified as medical devices that could be used in daily clinical settings. Therefore, using a bult-in microcontroller (72×57×12 mm) instead of a personal computer, we developed a portable stand-alone respiration measurement device with minimum workload in computing that can be used for non-contact measurement in 30 s using a Doppler radar. In this study, the problems of respiration measurement using a Doppler radar, such as miscounting of respiratory peaks were clarified, and proposed device with respiratory peaks miscount prevention algorithm achieved high accuracy RR measurement. Clinical testing was conducted on pediatric outpatients of Children's Medical Center, Showa University Koto Toyosu Hospital. The measurement accuracy of the system was confirmed to be comparable to the respiration measurement accuracy of stationary certified medical devices used in hospital, such as capnometers and the chest wall impedance method used in bedside monitors.</p>","PeriodicalId":50539,"journal":{"name":"Electronics and Communications in Japan","volume":"106 4","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a stand-alone portable respiratory rate monitor using a Doppler radar\",\"authors\":\"Miyu Katoh,&nbsp;Takeru Kanazawa,&nbsp;Yoshifusa Abe,&nbsp;Guanghao Sun,&nbsp;Takemi Matsui\",\"doi\":\"10.1002/ecj.12427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Respiratory rate (RR) is known to be a more accurate predictor of clinical deterioration than other vital signs. However, there were few respiration measurement devices certified as medical devices that could be used in daily clinical settings. Therefore, using a bult-in microcontroller (72×57×12 mm) instead of a personal computer, we developed a portable stand-alone respiration measurement device with minimum workload in computing that can be used for non-contact measurement in 30 s using a Doppler radar. In this study, the problems of respiration measurement using a Doppler radar, such as miscounting of respiratory peaks were clarified, and proposed device with respiratory peaks miscount prevention algorithm achieved high accuracy RR measurement. Clinical testing was conducted on pediatric outpatients of Children's Medical Center, Showa University Koto Toyosu Hospital. The measurement accuracy of the system was confirmed to be comparable to the respiration measurement accuracy of stationary certified medical devices used in hospital, such as capnometers and the chest wall impedance method used in bedside monitors.</p>\",\"PeriodicalId\":50539,\"journal\":{\"name\":\"Electronics and Communications in Japan\",\"volume\":\"106 4\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electronics and Communications in Japan\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ecj.12427\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electronics and Communications in Japan","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ecj.12427","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

呼吸频率(RR)比其他生命体征更准确地预测临床恶化。然而,很少有呼吸测量设备被认证为医疗设备,可以在日常临床环境中使用。因此,使用内置微控制器(72×57×12 mm)代替个人计算机,我们开发了一种便携式独立呼吸测量设备,其计算工作量最小,可用于30秒内使用多普勒雷达进行非接触式测量。本研究针对多普勒雷达呼吸测量中存在的呼吸峰值误计等问题进行了澄清,提出了一种带有呼吸峰值误计预防算法的装置,实现了高精度的RR测量。临床试验在昭和大学东丰洲医院儿童医学中心的儿科门诊患者中进行。经证实,该系统的测量精度可与医院使用的固定式认证医疗设备的呼吸测量精度相媲美,如床边监护仪中使用的血压计和胸壁阻抗法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of a stand-alone portable respiratory rate monitor using a Doppler radar

Respiratory rate (RR) is known to be a more accurate predictor of clinical deterioration than other vital signs. However, there were few respiration measurement devices certified as medical devices that could be used in daily clinical settings. Therefore, using a bult-in microcontroller (72×57×12 mm) instead of a personal computer, we developed a portable stand-alone respiration measurement device with minimum workload in computing that can be used for non-contact measurement in 30 s using a Doppler radar. In this study, the problems of respiration measurement using a Doppler radar, such as miscounting of respiratory peaks were clarified, and proposed device with respiratory peaks miscount prevention algorithm achieved high accuracy RR measurement. Clinical testing was conducted on pediatric outpatients of Children's Medical Center, Showa University Koto Toyosu Hospital. The measurement accuracy of the system was confirmed to be comparable to the respiration measurement accuracy of stationary certified medical devices used in hospital, such as capnometers and the chest wall impedance method used in bedside monitors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electronics and Communications in Japan
Electronics and Communications in Japan 工程技术-工程:电子与电气
CiteScore
0.60
自引率
0.00%
发文量
45
审稿时长
6-12 weeks
期刊介绍: Electronics and Communications in Japan (ECJ) publishes papers translated from the Transactions of the Institute of Electrical Engineers of Japan 12 times per year as an official journal of the Institute of Electrical Engineers of Japan (IEEJ). ECJ aims to provide world-class researches in highly diverse and sophisticated areas of Electrical and Electronic Engineering as well as in related disciplines with emphasis on electronic circuits, controls and communications. ECJ focuses on the following fields: - Electronic theory and circuits, - Control theory, - Communications, - Cryptography, - Biomedical fields, - Surveillance, - Robotics, - Sensors and actuators, - Micromachines, - Image analysis and signal analysis, - New materials. For works related to the science, technology, and applications of electric power, please refer to the sister journal Electrical Engineering in Japan (EEJ).
期刊最新文献
Issue Information Event-Triggered Robust Control of Robot Manipulators A Hardware Chaotic Neural Network With Gap Junction Models Effects of Controlling Assist Robots to Follow Lumbar Load on Muscle Fatigue Absolute Train Localization Based on the Identification of Surrounding Structures Using 1D LiDAR Sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1