{"title":"换热降压和换热角度为25o的百叶带间流量变化及距离分析","authors":"None Ishak Usman, None Kifli Umar, None Sandi Rais, None Rian A. Rahman","doi":"10.47577/technium.v17i.10068","DOIUrl":null,"url":null,"abstract":"This study aims to determine the effect of variations in flow rate and the louvered strip inclination angle on heat transfer in a double-pipe heat exchanger and the impact of variations in flow rate and inclination angle of the louvered strip on the inner tube pressure drop in a double-pipe heat exchanger. Three pieces of louvered strips at 50 mm, 70 mm, 90 mm are inserted into the inner tube of the heat exchanger with a constant tilt angle of 25°. Cold and hot water are used at a constant value where the cold-water flow rate is 600 liters/hour and V = 900 liters/hour, while the hot water flow rate is 1200 liters/hour. The inlet and outlet temperatures of both hot and cold water are measured, and the heat transfer characteristics of the heat exchanger are calculated as a result of the pressure drop that occurs in the inner tube due to the difference in height on the U-tube manometer used.","PeriodicalId":490649,"journal":{"name":"Technium","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Analysis Of Flow Capacity Variation and Distance Between Louvered Strip Constant Angle 25o Of Heat Transfer and Pressure Decrease On The Heat Exchanger\",\"authors\":\"None Ishak Usman, None Kifli Umar, None Sandi Rais, None Rian A. Rahman\",\"doi\":\"10.47577/technium.v17i.10068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims to determine the effect of variations in flow rate and the louvered strip inclination angle on heat transfer in a double-pipe heat exchanger and the impact of variations in flow rate and inclination angle of the louvered strip on the inner tube pressure drop in a double-pipe heat exchanger. Three pieces of louvered strips at 50 mm, 70 mm, 90 mm are inserted into the inner tube of the heat exchanger with a constant tilt angle of 25°. Cold and hot water are used at a constant value where the cold-water flow rate is 600 liters/hour and V = 900 liters/hour, while the hot water flow rate is 1200 liters/hour. The inlet and outlet temperatures of both hot and cold water are measured, and the heat transfer characteristics of the heat exchanger are calculated as a result of the pressure drop that occurs in the inner tube due to the difference in height on the U-tube manometer used.\",\"PeriodicalId\":490649,\"journal\":{\"name\":\"Technium\",\"volume\":\"90 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47577/technium.v17i.10068\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47577/technium.v17i.10068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An Analysis Of Flow Capacity Variation and Distance Between Louvered Strip Constant Angle 25o Of Heat Transfer and Pressure Decrease On The Heat Exchanger
This study aims to determine the effect of variations in flow rate and the louvered strip inclination angle on heat transfer in a double-pipe heat exchanger and the impact of variations in flow rate and inclination angle of the louvered strip on the inner tube pressure drop in a double-pipe heat exchanger. Three pieces of louvered strips at 50 mm, 70 mm, 90 mm are inserted into the inner tube of the heat exchanger with a constant tilt angle of 25°. Cold and hot water are used at a constant value where the cold-water flow rate is 600 liters/hour and V = 900 liters/hour, while the hot water flow rate is 1200 liters/hour. The inlet and outlet temperatures of both hot and cold water are measured, and the heat transfer characteristics of the heat exchanger are calculated as a result of the pressure drop that occurs in the inner tube due to the difference in height on the U-tube manometer used.