基于三线插值离散傅里叶变换的电力系统谐波分析方法

IF 1.2 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Archives of Electrical Engineering Pub Date : 2023-11-06 DOI:10.24425/aee.2022.141670
Ling Liu, Jinsong Zhang
{"title":"基于三线插值离散傅里叶变换的电力系统谐波分析方法","authors":"Ling Liu, Jinsong Zhang","doi":"10.24425/aee.2022.141670","DOIUrl":null,"url":null,"abstract":": The discrete Fourier transform (DFT) is a principal method for power system harmonic analysis. The fundamental frequency of the power system increases or decreases following load changes during normal operation. It is difficult to achieve synchronous sampling and integer period truncation in power harmonic analysis. The resulting spectrum leakage affects the accuracy of the measurement results. For this reason, a windowed interpolation DFT method for power system harmonic analysis to reduce errors was presented in this paper. First, the frequency domain expression of the windowed signal Fourier transform is analyzed. Then, the magnitude of the three discrete spectrum lines near the harmonic frequency point is used to determine the accurate position of the harmonic spectrum. Then, the calculation of the amplitude, frequency, and phase of harmonics is presented. The triple-line interpolation DFT can improve the accuracy of electrical harmonic analysis. Based on the algorithm, the practical rectification formulas were obtained by using the polynomial approximation method. The simulation results show that the fast attenuation of window function sidelobe is the key to reduce the error. The triple-line interpolation DFT based on Hanning, Blackman, Nuttall 3-Term windows has higher calculation accuracy, which can meet the requirements of electrical harmonic analysis.","PeriodicalId":45464,"journal":{"name":"Archives of Electrical Engineering","volume":"15 2","pages":"0"},"PeriodicalIF":1.2000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An approach to power system harmonic analysis based on triple-line interpolation discrete Fourier transform\",\"authors\":\"Ling Liu, Jinsong Zhang\",\"doi\":\"10.24425/aee.2022.141670\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": The discrete Fourier transform (DFT) is a principal method for power system harmonic analysis. The fundamental frequency of the power system increases or decreases following load changes during normal operation. It is difficult to achieve synchronous sampling and integer period truncation in power harmonic analysis. The resulting spectrum leakage affects the accuracy of the measurement results. For this reason, a windowed interpolation DFT method for power system harmonic analysis to reduce errors was presented in this paper. First, the frequency domain expression of the windowed signal Fourier transform is analyzed. Then, the magnitude of the three discrete spectrum lines near the harmonic frequency point is used to determine the accurate position of the harmonic spectrum. Then, the calculation of the amplitude, frequency, and phase of harmonics is presented. The triple-line interpolation DFT can improve the accuracy of electrical harmonic analysis. Based on the algorithm, the practical rectification formulas were obtained by using the polynomial approximation method. The simulation results show that the fast attenuation of window function sidelobe is the key to reduce the error. The triple-line interpolation DFT based on Hanning, Blackman, Nuttall 3-Term windows has higher calculation accuracy, which can meet the requirements of electrical harmonic analysis.\",\"PeriodicalId\":45464,\"journal\":{\"name\":\"Archives of Electrical Engineering\",\"volume\":\"15 2\",\"pages\":\"0\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/aee.2022.141670\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/aee.2022.141670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An approach to power system harmonic analysis based on triple-line interpolation discrete Fourier transform
: The discrete Fourier transform (DFT) is a principal method for power system harmonic analysis. The fundamental frequency of the power system increases or decreases following load changes during normal operation. It is difficult to achieve synchronous sampling and integer period truncation in power harmonic analysis. The resulting spectrum leakage affects the accuracy of the measurement results. For this reason, a windowed interpolation DFT method for power system harmonic analysis to reduce errors was presented in this paper. First, the frequency domain expression of the windowed signal Fourier transform is analyzed. Then, the magnitude of the three discrete spectrum lines near the harmonic frequency point is used to determine the accurate position of the harmonic spectrum. Then, the calculation of the amplitude, frequency, and phase of harmonics is presented. The triple-line interpolation DFT can improve the accuracy of electrical harmonic analysis. Based on the algorithm, the practical rectification formulas were obtained by using the polynomial approximation method. The simulation results show that the fast attenuation of window function sidelobe is the key to reduce the error. The triple-line interpolation DFT based on Hanning, Blackman, Nuttall 3-Term windows has higher calculation accuracy, which can meet the requirements of electrical harmonic analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Archives of Electrical Engineering
Archives of Electrical Engineering ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
2.40
自引率
53.80%
发文量
0
审稿时长
18 weeks
期刊介绍: The journal publishes original papers in the field of electrical engineering which covers, but not limited to, the following scope: - Control - Electrical machines and transformers - Electrical & magnetic fields problems - Electric traction - Electro heat - Fuel cells, micro machines, hybrid vehicles - Nondestructive testing & Nondestructive evaluation - Electrical power engineering - Power electronics
期刊最新文献
Efficient cloud-based digital-physical testing method for feeder automation system in electrical power distribution network 148853 Optimal size and location of dispatchable distributed generators in an autonomous microgrid using Honey Badger algorithm Risk of irreversible demagnetisation under transient states of the line start permanent magnet synchronous motor taking into account magnet temperature Solar power and multi-battery for new configuration DC microgrid using centralized control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1