{"title":"压力秤半自动校准系统的设计","authors":"","doi":"10.24425/mms.2022.143073","DOIUrl":null,"url":null,"abstract":"In this study, a digital manometer was used as a transfer standard to perform calibration of a pneumatic pressure balance. The same pressure balance was calibrated with the cross-floating method based on falling rate determination (FRD). Average of differences among the effective area results show an agreement of less than 10 ppm between the digital manometer-assisted calibration (DMAC) method and the FRD method. The method in which a digital pressure gauge is used as a transfer standard not only facilitates calibration but also enables the automation of pressure balance calibration. Full automation of pressure balance calibration requires an automatic mass loading system for both the reference instrument and the device under test. Since there is a lot of different kinds of pressure balances, it is nearly impossible for a pressure metrology laboratory to have an automatic mass-handler system for every type of pressure balance. Therefore, a more efficient way in which automated mass-handler systems are not required 𝑖.𝑒. , a semi-automatic calibration system, is designed. For that purpose, two different calibration procedures, increasing-decreasing cycles, and pressurize-vent (P-V) procedures are performed and compared. The equivalence of procedure results makes the semi-automated calibration design of pressure balances possible. The most distinguishing advantages of a semi-automated calibration system are the applicability to any type of pressure balance and low cost compared to full automation","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":"40 4","pages":"0"},"PeriodicalIF":1.0000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of semi-automated calibration system for pressure balances\",\"authors\":\"\",\"doi\":\"10.24425/mms.2022.143073\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a digital manometer was used as a transfer standard to perform calibration of a pneumatic pressure balance. The same pressure balance was calibrated with the cross-floating method based on falling rate determination (FRD). Average of differences among the effective area results show an agreement of less than 10 ppm between the digital manometer-assisted calibration (DMAC) method and the FRD method. The method in which a digital pressure gauge is used as a transfer standard not only facilitates calibration but also enables the automation of pressure balance calibration. Full automation of pressure balance calibration requires an automatic mass loading system for both the reference instrument and the device under test. Since there is a lot of different kinds of pressure balances, it is nearly impossible for a pressure metrology laboratory to have an automatic mass-handler system for every type of pressure balance. Therefore, a more efficient way in which automated mass-handler systems are not required 𝑖.𝑒. , a semi-automatic calibration system, is designed. For that purpose, two different calibration procedures, increasing-decreasing cycles, and pressurize-vent (P-V) procedures are performed and compared. The equivalence of procedure results makes the semi-automated calibration design of pressure balances possible. The most distinguishing advantages of a semi-automated calibration system are the applicability to any type of pressure balance and low cost compared to full automation\",\"PeriodicalId\":18394,\"journal\":{\"name\":\"Metrology and Measurement Systems\",\"volume\":\"40 4\",\"pages\":\"0\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrology and Measurement Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/mms.2022.143073\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrology and Measurement Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/mms.2022.143073","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of semi-automated calibration system for pressure balances
In this study, a digital manometer was used as a transfer standard to perform calibration of a pneumatic pressure balance. The same pressure balance was calibrated with the cross-floating method based on falling rate determination (FRD). Average of differences among the effective area results show an agreement of less than 10 ppm between the digital manometer-assisted calibration (DMAC) method and the FRD method. The method in which a digital pressure gauge is used as a transfer standard not only facilitates calibration but also enables the automation of pressure balance calibration. Full automation of pressure balance calibration requires an automatic mass loading system for both the reference instrument and the device under test. Since there is a lot of different kinds of pressure balances, it is nearly impossible for a pressure metrology laboratory to have an automatic mass-handler system for every type of pressure balance. Therefore, a more efficient way in which automated mass-handler systems are not required 𝑖.𝑒. , a semi-automatic calibration system, is designed. For that purpose, two different calibration procedures, increasing-decreasing cycles, and pressurize-vent (P-V) procedures are performed and compared. The equivalence of procedure results makes the semi-automated calibration design of pressure balances possible. The most distinguishing advantages of a semi-automated calibration system are the applicability to any type of pressure balance and low cost compared to full automation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metrology and Measurement Systems
Metrology and Measurement Systems INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
10.00%
发文量
0
审稿时长
6 months
期刊介绍: Contributions are invited on all aspects of the research, development and applications of the measurement science and technology. The list of topics covered includes: theory and general principles of measurement; measurement of physical, chemical and biological quantities; medical measurements; sensors and transducers; measurement data acquisition; measurement signal transmission; processing and data analysis; measurement systems and embedded systems; design, manufacture and evaluation of instruments. The average publication cycle is 6 months.
期刊最新文献
148534 Selected Technical Issues of Deep Neural Networks for Image Classification Purposes Statistical process control of commercial force-sensing resistors Physical foundations determining spectral characteristics measured in Bragg gratings subjected to bending Anatomical and functional assessment of patency of the upper respiratory tract in selected respiratory disorders – part 2
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1