{"title":"非对称损伤复合材料三层环形板的稳定状态评价","authors":"Dorota Pawlus","doi":"10.24425/ame.2019.126370","DOIUrl":null,"url":null,"abstract":"The paper presents the response of a three-layered annular plate with damaged laminated facings to the loads acting in their planes. The presented problem concerns the analysis of the combination of global plate failure in the form of buckling with the local micro defects, like fibre or matrix cracks, located in the laminas. The plate structure consists of thin laminated, fibre-reinforced composite facings and a thicker foam core. The matrix and fibre cracks of facings laminas can be transversally symmetrically or asymmetrically located in plate structure. Critical static and dynamic stability analyses were carried out solving the problem numerically and analytically. The numerical results show the static and dynamic stability state of the composite plate with different combinations of damages. The final results are compared with those for undamaged structure of the plate and treated as quasi-isotropic ones. The analysed problem makes it possible to evaluate the use of the non-ideal composite plate structure in practical applications.","PeriodicalId":45083,"journal":{"name":"Archive of Mechanical Engineering","volume":"569 3","pages":"0"},"PeriodicalIF":1.2000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stability state evaluation of composite three-layered annular plates with asymmetrical damage\",\"authors\":\"Dorota Pawlus\",\"doi\":\"10.24425/ame.2019.126370\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the response of a three-layered annular plate with damaged laminated facings to the loads acting in their planes. The presented problem concerns the analysis of the combination of global plate failure in the form of buckling with the local micro defects, like fibre or matrix cracks, located in the laminas. The plate structure consists of thin laminated, fibre-reinforced composite facings and a thicker foam core. The matrix and fibre cracks of facings laminas can be transversally symmetrically or asymmetrically located in plate structure. Critical static and dynamic stability analyses were carried out solving the problem numerically and analytically. The numerical results show the static and dynamic stability state of the composite plate with different combinations of damages. The final results are compared with those for undamaged structure of the plate and treated as quasi-isotropic ones. The analysed problem makes it possible to evaluate the use of the non-ideal composite plate structure in practical applications.\",\"PeriodicalId\":45083,\"journal\":{\"name\":\"Archive of Mechanical Engineering\",\"volume\":\"569 3\",\"pages\":\"0\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archive of Mechanical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/ame.2019.126370\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archive of Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/ame.2019.126370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Stability state evaluation of composite three-layered annular plates with asymmetrical damage
The paper presents the response of a three-layered annular plate with damaged laminated facings to the loads acting in their planes. The presented problem concerns the analysis of the combination of global plate failure in the form of buckling with the local micro defects, like fibre or matrix cracks, located in the laminas. The plate structure consists of thin laminated, fibre-reinforced composite facings and a thicker foam core. The matrix and fibre cracks of facings laminas can be transversally symmetrically or asymmetrically located in plate structure. Critical static and dynamic stability analyses were carried out solving the problem numerically and analytically. The numerical results show the static and dynamic stability state of the composite plate with different combinations of damages. The final results are compared with those for undamaged structure of the plate and treated as quasi-isotropic ones. The analysed problem makes it possible to evaluate the use of the non-ideal composite plate structure in practical applications.
期刊介绍:
Archive of Mechanical Engineering is an international journal publishing works of wide significance, originality and relevance in most branches of mechanical engineering. The journal is peer-reviewed and is published both in electronic and printed form. Archive of Mechanical Engineering publishes original papers which have not been previously published in other journal, and are not being prepared for publication elsewhere. The publisher will not be held legally responsible should there be any claims for compensation. The journal accepts papers in English.