制革污泥堆肥施用7年后的土壤物理特性

IF 1.5 4区 农林科学 Acta Scientiarum-agronomy Pub Date : 2023-08-22 DOI:10.4025/actasciagron.v45i1.60748
Ricardo Silva de Sousa, Luís Alfredo Pinheiro Leal Nunes, Francisco de Alcântara Neto, Henrique Antunes de Souza, Ademir Sérgio Ferreira de Araújo
{"title":"制革污泥堆肥施用7年后的土壤物理特性","authors":"Ricardo Silva de Sousa, Luís Alfredo Pinheiro Leal Nunes, Francisco de Alcântara Neto, Henrique Antunes de Souza, Ademir Sérgio Ferreira de Araújo","doi":"10.4025/actasciagron.v45i1.60748","DOIUrl":null,"url":null,"abstract":"This study was performed to investigate the effects of composted tannery sludge (CTS) on the physical properties of tropical sandy soil after seven years of CTS application. CTS was applied to a Fluvisol at five rates (0.0, 2.5, 5.0, 10.0, and 20.0 Mg ha-1) in experimental plots (sized 20 m2) with four replications. Water infiltration into the soil was determined in the field with the concentric-ring infiltrometer method. Bulk density, total porosity, macroporosity, and microporosity were determined in the soil samples. The permanent CTS application altered the physical properties of the soil and led to a decrease in bulk density. The total porosity, microporosity and macroporosity values in the CTS-applied soil ranged from 44.1–51.7, 34.6–39.4, and 9.1–12.8%, respectively. Water-infiltration rates were significantly influenced by CTS. The cumulative infiltrated water in the soil varied from 21.3–34.7 cm. The basic infiltration rate was lower in the unamended soil and increased with an increase in the rate of CTS application. This study confirmed that the physical soil parameters improved after the permanent CTS application. Therefore, this application may be a suitable strategy for improving physical soil properties over time.","PeriodicalId":7197,"journal":{"name":"Acta Scientiarum-agronomy","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Physical soil properties after seven years of composted tannery-sludge application\",\"authors\":\"Ricardo Silva de Sousa, Luís Alfredo Pinheiro Leal Nunes, Francisco de Alcântara Neto, Henrique Antunes de Souza, Ademir Sérgio Ferreira de Araújo\",\"doi\":\"10.4025/actasciagron.v45i1.60748\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study was performed to investigate the effects of composted tannery sludge (CTS) on the physical properties of tropical sandy soil after seven years of CTS application. CTS was applied to a Fluvisol at five rates (0.0, 2.5, 5.0, 10.0, and 20.0 Mg ha-1) in experimental plots (sized 20 m2) with four replications. Water infiltration into the soil was determined in the field with the concentric-ring infiltrometer method. Bulk density, total porosity, macroporosity, and microporosity were determined in the soil samples. The permanent CTS application altered the physical properties of the soil and led to a decrease in bulk density. The total porosity, microporosity and macroporosity values in the CTS-applied soil ranged from 44.1–51.7, 34.6–39.4, and 9.1–12.8%, respectively. Water-infiltration rates were significantly influenced by CTS. The cumulative infiltrated water in the soil varied from 21.3–34.7 cm. The basic infiltration rate was lower in the unamended soil and increased with an increase in the rate of CTS application. This study confirmed that the physical soil parameters improved after the permanent CTS application. Therefore, this application may be a suitable strategy for improving physical soil properties over time.\",\"PeriodicalId\":7197,\"journal\":{\"name\":\"Acta Scientiarum-agronomy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Scientiarum-agronomy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4025/actasciagron.v45i1.60748\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Scientiarum-agronomy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4025/actasciagron.v45i1.60748","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在探讨堆肥制革厂污泥(CTS)在施用7年后对热带砂质土壤物理性质的影响。CTS以5种浓度(0.0、2.5、5.0、10.0和20.0 Mg ha-1)作用于Fluvisol,实验面积为20 m2,共4个重复。采用同心圆环入渗仪测定了田间土壤的入渗量。测定了土样的容重、总孔隙度、宏观孔隙度和微观孔隙度。永久施用CTS改变了土壤的物理性质,导致容重下降。施用cts的土壤总孔隙度、微孔隙度和宏观孔隙度分别为44.1 ~ 51.7、34.6 ~ 39.4和9.1 ~ 12.8%。水分入渗速率受CTS影响显著。土壤累计入渗水量在21.3 ~ 34.7 cm之间变化。基本入渗速率在未改良土壤中较低,随CTS施用量的增加而增加。本研究证实,永久施用CTS后,土壤物理参数有所改善。因此,随着时间的推移,这种应用可能是改善土壤物理性质的合适策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Physical soil properties after seven years of composted tannery-sludge application
This study was performed to investigate the effects of composted tannery sludge (CTS) on the physical properties of tropical sandy soil after seven years of CTS application. CTS was applied to a Fluvisol at five rates (0.0, 2.5, 5.0, 10.0, and 20.0 Mg ha-1) in experimental plots (sized 20 m2) with four replications. Water infiltration into the soil was determined in the field with the concentric-ring infiltrometer method. Bulk density, total porosity, macroporosity, and microporosity were determined in the soil samples. The permanent CTS application altered the physical properties of the soil and led to a decrease in bulk density. The total porosity, microporosity and macroporosity values in the CTS-applied soil ranged from 44.1–51.7, 34.6–39.4, and 9.1–12.8%, respectively. Water-infiltration rates were significantly influenced by CTS. The cumulative infiltrated water in the soil varied from 21.3–34.7 cm. The basic infiltration rate was lower in the unamended soil and increased with an increase in the rate of CTS application. This study confirmed that the physical soil parameters improved after the permanent CTS application. Therefore, this application may be a suitable strategy for improving physical soil properties over time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
45
期刊介绍: The journal publishes original articles in all areas of Agronomy, including soil sciences, agricultural entomology, soil fertility and manuring, soil physics, physiology of cultivated plants, phytopathology, phyto-health, phytotechny, genesis, morphology and soil classification, management and conservation of soil, integrated management of plant pests, vegetal improvement, agricultural microbiology, agricultural parasitology, production and processing of seeds.
期刊最新文献
Effect of plant-growth regulators, adjuvants and artificial pollination on the fixation and quality of Annona squamosa L cultivars’ fruit Long-term effects of cover crops on physical-hydric properties of compacted soil Pyruvate supplementation in cotton under water restriction varying the phenological phases Multi-trait multi-environment models for selecting high-performance and stable eucalyptus clones Strategies for reducing the impact of clubroot on broccoli cultivation in tropical mountain regions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1