某医院室外雨水排水污染研究

IF 1.6 Q3 WATER RESOURCES Water Practice and Technology Pub Date : 2023-11-03 DOI:10.2166/wpt.2023.185
Ming Fang, Chunhu Chen, Xinren Ding, Zhen Qian
{"title":"某医院室外雨水排水污染研究","authors":"Ming Fang, Chunhu Chen, Xinren Ding, Zhen Qian","doi":"10.2166/wpt.2023.185","DOIUrl":null,"url":null,"abstract":"Abstract The outdoor rainwater drainage pollution in a large general hospital poses considerable threats to the environment and our health. A systematic analysis method was summarized in the investigation practice. Results showed that the pipe network damage caused by uneven geological settlement was the main reason for the pollution of the rainwater pipe network in the hospital. Countermeasures such as settlement repair and geological foundation reinforcement, rainwater and sewage pipeline transformation, the repair of mixed connection of rainwater and sewage pipes and polluted water sources, drainage health safety in isolated areas, and emergency storage tanks were discussed. After implementing the measures, the NH3-N measured value was within 0.82 mg/L, and the average removal rate was 97.4%. The COD concentration also decreased significantly with an average of 12 mg/L and the average removal rate was 91.8%. The results show that the reconstruction can effectively deal with the problem of outdoor rainwater drainage pollution in the hospital. The study has specific engineering reference significance for medical building drainage system's health and safety research.","PeriodicalId":23794,"journal":{"name":"Water Practice and Technology","volume":"42 14","pages":"0"},"PeriodicalIF":1.6000,"publicationDate":"2023-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of outdoor rainwater drainage pollution in a hospital\",\"authors\":\"Ming Fang, Chunhu Chen, Xinren Ding, Zhen Qian\",\"doi\":\"10.2166/wpt.2023.185\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The outdoor rainwater drainage pollution in a large general hospital poses considerable threats to the environment and our health. A systematic analysis method was summarized in the investigation practice. Results showed that the pipe network damage caused by uneven geological settlement was the main reason for the pollution of the rainwater pipe network in the hospital. Countermeasures such as settlement repair and geological foundation reinforcement, rainwater and sewage pipeline transformation, the repair of mixed connection of rainwater and sewage pipes and polluted water sources, drainage health safety in isolated areas, and emergency storage tanks were discussed. After implementing the measures, the NH3-N measured value was within 0.82 mg/L, and the average removal rate was 97.4%. The COD concentration also decreased significantly with an average of 12 mg/L and the average removal rate was 91.8%. The results show that the reconstruction can effectively deal with the problem of outdoor rainwater drainage pollution in the hospital. The study has specific engineering reference significance for medical building drainage system's health and safety research.\",\"PeriodicalId\":23794,\"journal\":{\"name\":\"Water Practice and Technology\",\"volume\":\"42 14\",\"pages\":\"0\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Practice and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/wpt.2023.185\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"WATER RESOURCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Practice and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/wpt.2023.185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

摘要

某大型综合医院室外雨水排水污染对环境和人体健康构成相当大的威胁。在调查实践中总结出系统的分析方法。结果表明,不均匀地质沉降造成的管网破坏是造成医院雨水管网污染的主要原因。探讨了沉降修复和地质基础加固、雨污水管道改造、雨污水管道与污染水源混接修复、边远地区排水卫生安全、应急储罐等对策。实施该措施后,NH3-N测定值在0.82 mg/L以内,平均去除率为97.4%。COD浓度也显著下降,平均为12 mg/L,平均去除率为91.8%。结果表明,改造能有效解决医院室外雨水排水污染问题。该研究对医疗建筑排水系统的健康安全研究具有特定的工程参考意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study of outdoor rainwater drainage pollution in a hospital
Abstract The outdoor rainwater drainage pollution in a large general hospital poses considerable threats to the environment and our health. A systematic analysis method was summarized in the investigation practice. Results showed that the pipe network damage caused by uneven geological settlement was the main reason for the pollution of the rainwater pipe network in the hospital. Countermeasures such as settlement repair and geological foundation reinforcement, rainwater and sewage pipeline transformation, the repair of mixed connection of rainwater and sewage pipes and polluted water sources, drainage health safety in isolated areas, and emergency storage tanks were discussed. After implementing the measures, the NH3-N measured value was within 0.82 mg/L, and the average removal rate was 97.4%. The COD concentration also decreased significantly with an average of 12 mg/L and the average removal rate was 91.8%. The results show that the reconstruction can effectively deal with the problem of outdoor rainwater drainage pollution in the hospital. The study has specific engineering reference significance for medical building drainage system's health and safety research.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
6.20%
发文量
136
审稿时长
14 weeks
期刊最新文献
Hydro-geochemical characterisation and modelling of groundwater in Chikun Local Government Area of Kaduna state, Nigeria A methodology for temporal disaggregation of daily rain gauge data using satellite precipitation product for improved accuracy in hydrologic simulation ACWA: an AI-driven cyber-physical testbed for intelligent water systems Phosphorus removal from ore waste in aqueous solution with different mass of ore waste adsorbent from the Johor mine site Assessment of risks to the quality of water supplied in Bushenyi-Uganda using the water safety plan approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1