Jiyan Liu, Dong Li, Zhelong Wang, Weishuai Wang, Meng Li
{"title":"基于改进遗传算法的新能源柔性负荷控制","authors":"Jiyan Liu, Dong Li, Zhelong Wang, Weishuai Wang, Meng Li","doi":"10.1177/0309524x231203685","DOIUrl":null,"url":null,"abstract":"In the medium and low voltage distribution network, the load form of users is complex and changeable. There are a large number of single-phase and two-phase loads connected to the distribution network, resulting in a three-phase unbalanced operation of the distribution network. With the development of the new energy, the high proportion of distributed new energy will further aggravate the three-phase imbalance of the distribution network. Therefore, this paper proposes a coordinated optimization framework of droop parameters based on the multi-converter droop control, which takes the minimum loss of the distribution network as the optimization objective, and optimizes the reference point and the slope of the VSC droop hierarchically. A small-signal stability optimization dispatching method for the VSC droop slope in the DC distribution network is proposed. By adding small-signal stability constraints to the slope optimization model, the optimal slope command and slope stability region which can ensure the small-signal stable operation of the system are obtained. Experiments show that the optimization model of the VSC small-signal stability slope can make the droop control instruction significantly improve the small-signal stability of the system to adapt to the intra-day source load power fluctuations with a small economic cost. The slope stability region pre-optimization model can provide a reliable stability slope upper limit for the slope optimization problem based on ensuring the system operation economy. The research in this paper can make full use of the flexible control ability of power electronic equipment, and then suppress the three-phase imbalance, which is of great significance to improve the security and economy of the distribution system operation.","PeriodicalId":51570,"journal":{"name":"Wind Engineering","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flexible load control of new energy based on improved genetic algorithm\",\"authors\":\"Jiyan Liu, Dong Li, Zhelong Wang, Weishuai Wang, Meng Li\",\"doi\":\"10.1177/0309524x231203685\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the medium and low voltage distribution network, the load form of users is complex and changeable. There are a large number of single-phase and two-phase loads connected to the distribution network, resulting in a three-phase unbalanced operation of the distribution network. With the development of the new energy, the high proportion of distributed new energy will further aggravate the three-phase imbalance of the distribution network. Therefore, this paper proposes a coordinated optimization framework of droop parameters based on the multi-converter droop control, which takes the minimum loss of the distribution network as the optimization objective, and optimizes the reference point and the slope of the VSC droop hierarchically. A small-signal stability optimization dispatching method for the VSC droop slope in the DC distribution network is proposed. By adding small-signal stability constraints to the slope optimization model, the optimal slope command and slope stability region which can ensure the small-signal stable operation of the system are obtained. Experiments show that the optimization model of the VSC small-signal stability slope can make the droop control instruction significantly improve the small-signal stability of the system to adapt to the intra-day source load power fluctuations with a small economic cost. The slope stability region pre-optimization model can provide a reliable stability slope upper limit for the slope optimization problem based on ensuring the system operation economy. The research in this paper can make full use of the flexible control ability of power electronic equipment, and then suppress the three-phase imbalance, which is of great significance to improve the security and economy of the distribution system operation.\",\"PeriodicalId\":51570,\"journal\":{\"name\":\"Wind Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wind Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/0309524x231203685\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wind Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/0309524x231203685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Flexible load control of new energy based on improved genetic algorithm
In the medium and low voltage distribution network, the load form of users is complex and changeable. There are a large number of single-phase and two-phase loads connected to the distribution network, resulting in a three-phase unbalanced operation of the distribution network. With the development of the new energy, the high proportion of distributed new energy will further aggravate the three-phase imbalance of the distribution network. Therefore, this paper proposes a coordinated optimization framework of droop parameters based on the multi-converter droop control, which takes the minimum loss of the distribution network as the optimization objective, and optimizes the reference point and the slope of the VSC droop hierarchically. A small-signal stability optimization dispatching method for the VSC droop slope in the DC distribution network is proposed. By adding small-signal stability constraints to the slope optimization model, the optimal slope command and slope stability region which can ensure the small-signal stable operation of the system are obtained. Experiments show that the optimization model of the VSC small-signal stability slope can make the droop control instruction significantly improve the small-signal stability of the system to adapt to the intra-day source load power fluctuations with a small economic cost. The slope stability region pre-optimization model can provide a reliable stability slope upper limit for the slope optimization problem based on ensuring the system operation economy. The research in this paper can make full use of the flexible control ability of power electronic equipment, and then suppress the three-phase imbalance, which is of great significance to improve the security and economy of the distribution system operation.
期刊介绍:
Having been in continuous publication since 1977, Wind Engineering is the oldest and most authoritative English language journal devoted entirely to the technology of wind energy. Under the direction of a distinguished editor and editorial board, Wind Engineering appears bimonthly with fully refereed contributions from active figures in the field, book notices, and summaries of the more interesting papers from other sources. Papers are published in Wind Engineering on: the aerodynamics of rotors and blades; machine subsystems and components; design; test programmes; power generation and transmission; measuring and recording techniques; installations and applications; and economic, environmental and legal aspects.