建立和应用国家 SARS-CoV-2 抗原检测试剂盒参考面板

IF 3.5 Q1 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Biosafety and Health Pub Date : 2023-12-01 DOI:10.1016/j.bsheal.2023.10.002
Tingting Ma , Donglai Liu , Keliang Lyu , Tingting Gao , Dawei Shi , Lanqing Zhao , Shu Shen , Yabin Tian , Sihong Xu , Haiwei Zhou
{"title":"建立和应用国家 SARS-CoV-2 抗原检测试剂盒参考面板","authors":"Tingting Ma ,&nbsp;Donglai Liu ,&nbsp;Keliang Lyu ,&nbsp;Tingting Gao ,&nbsp;Dawei Shi ,&nbsp;Lanqing Zhao ,&nbsp;Shu Shen ,&nbsp;Yabin Tian ,&nbsp;Sihong Xu ,&nbsp;Haiwei Zhou","doi":"10.1016/j.bsheal.2023.10.002","DOIUrl":null,"url":null,"abstract":"<div><p>To develop a national reference panel for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection kit and establish a quality standard. The cultures of SARS-CoV-2 and other pathogens were collected to establish a national reference panel for SARS-CoV-2 antigen detection. The stability and homogeneity of the reference panel were evaluated. Based on World Health Organization (WHO) guidance and nucleic acid quantitative results, a quality standard reference panel was established. Currently, three generations of SARS-CoV-2 antigen national reference materials with batch numbers 370095–202001, 370095–202202, and 370095–202203 have been successfully established. These national reference panels comprised 8 positive samples, 20 negative samples, 1 repetitive sample, and 1 lower detection limit sample. The stability and homogeneity of the reference panel meet the requirements. The quality standards are as follows: the positive and negative coincidence rates are 8/8 and 20/20, respectively. The 10 test results of the medium and low-concentration repetitive reference materials should be positive, and the color rendering should be uniform (or the coefficient of variance should not be higher than 20.0%). The lower detection limit should be at least 5 × 10<sup>5</sup> U/mL (equivalent to copies/mL), and higher concentrations above the lower detection limit must be positive. A national reference panel for the SARS-CoV-2 antigen detection kit has been established. As the standard of SARS-CoV-2 antigen reagents, the reference panel has played a crucial role in the pre-marketing quality evaluation and post-marketing quality supervision in China.</p></div>","PeriodicalId":36178,"journal":{"name":"Biosafety and Health","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S259005362300126X/pdfft?md5=d9245d6267bc792587bef77303b11076&pid=1-s2.0-S259005362300126X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Establishment and application of national reference panels for SARS-CoV-2 antigen detection kit\",\"authors\":\"Tingting Ma ,&nbsp;Donglai Liu ,&nbsp;Keliang Lyu ,&nbsp;Tingting Gao ,&nbsp;Dawei Shi ,&nbsp;Lanqing Zhao ,&nbsp;Shu Shen ,&nbsp;Yabin Tian ,&nbsp;Sihong Xu ,&nbsp;Haiwei Zhou\",\"doi\":\"10.1016/j.bsheal.2023.10.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>To develop a national reference panel for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection kit and establish a quality standard. The cultures of SARS-CoV-2 and other pathogens were collected to establish a national reference panel for SARS-CoV-2 antigen detection. The stability and homogeneity of the reference panel were evaluated. Based on World Health Organization (WHO) guidance and nucleic acid quantitative results, a quality standard reference panel was established. Currently, three generations of SARS-CoV-2 antigen national reference materials with batch numbers 370095–202001, 370095–202202, and 370095–202203 have been successfully established. These national reference panels comprised 8 positive samples, 20 negative samples, 1 repetitive sample, and 1 lower detection limit sample. The stability and homogeneity of the reference panel meet the requirements. The quality standards are as follows: the positive and negative coincidence rates are 8/8 and 20/20, respectively. The 10 test results of the medium and low-concentration repetitive reference materials should be positive, and the color rendering should be uniform (or the coefficient of variance should not be higher than 20.0%). The lower detection limit should be at least 5 × 10<sup>5</sup> U/mL (equivalent to copies/mL), and higher concentrations above the lower detection limit must be positive. A national reference panel for the SARS-CoV-2 antigen detection kit has been established. As the standard of SARS-CoV-2 antigen reagents, the reference panel has played a crucial role in the pre-marketing quality evaluation and post-marketing quality supervision in China.</p></div>\",\"PeriodicalId\":36178,\"journal\":{\"name\":\"Biosafety and Health\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S259005362300126X/pdfft?md5=d9245d6267bc792587bef77303b11076&pid=1-s2.0-S259005362300126X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosafety and Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S259005362300126X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosafety and Health","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S259005362300126X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

摘要

开发严重急性呼吸系统综合征冠状病毒 2(SARS-CoV-2)抗原检测试剂盒的国家参考试剂盒,并制定质量标准。收集 SARS-CoV-2 和其他病原体的培养物,建立 SARS-CoV-2 抗原检测国家参考试剂盒。对参考面板的稳定性和同质性进行了评估。根据世界卫生组织(WHO)的指导意见和核酸定量结果,建立了质量标准参考板。目前,已成功建立了三代 SARS-CoV-2 抗原国家参考材料,批号分别为 370095-202001、370095-202202 和 370095-202203。这些国家参考样本包括 8 份阳性样本、20 份阴性样本、1 份重复样本和 1 份检测下限样本。参比板的稳定性和均一性均符合要求。质量标准如下:阳性和阴性重合率分别为 8/8 和 20/20。中、低浓度重复性参比物的 10 次检测结果均应为阳性,显色均匀(或方差系数不高于 20.0%)。检测下限应至少为 5 × 105 U/mL(相当于拷贝数/毫升),高于检测下限的浓度必须为阳性。SARS-CoV-2 抗原检测试剂盒的国家参考面板已经建立。作为SARS-CoV-2抗原试剂的标准,参比架在我国SARS-CoV-2试剂上市前的质量评价和上市后的质量监管中发挥了重要作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Establishment and application of national reference panels for SARS-CoV-2 antigen detection kit

To develop a national reference panel for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection kit and establish a quality standard. The cultures of SARS-CoV-2 and other pathogens were collected to establish a national reference panel for SARS-CoV-2 antigen detection. The stability and homogeneity of the reference panel were evaluated. Based on World Health Organization (WHO) guidance and nucleic acid quantitative results, a quality standard reference panel was established. Currently, three generations of SARS-CoV-2 antigen national reference materials with batch numbers 370095–202001, 370095–202202, and 370095–202203 have been successfully established. These national reference panels comprised 8 positive samples, 20 negative samples, 1 repetitive sample, and 1 lower detection limit sample. The stability and homogeneity of the reference panel meet the requirements. The quality standards are as follows: the positive and negative coincidence rates are 8/8 and 20/20, respectively. The 10 test results of the medium and low-concentration repetitive reference materials should be positive, and the color rendering should be uniform (or the coefficient of variance should not be higher than 20.0%). The lower detection limit should be at least 5 × 105 U/mL (equivalent to copies/mL), and higher concentrations above the lower detection limit must be positive. A national reference panel for the SARS-CoV-2 antigen detection kit has been established. As the standard of SARS-CoV-2 antigen reagents, the reference panel has played a crucial role in the pre-marketing quality evaluation and post-marketing quality supervision in China.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosafety and Health
Biosafety and Health Medicine-Infectious Diseases
CiteScore
7.60
自引率
0.00%
发文量
116
审稿时长
66 days
期刊最新文献
Establishment of the benchmarking tool for evaluating the operation of biorepositories for pathogenic resource using a modified Delphi method An online survey among convalescents 5 months post SARS-CoV-2 infection in China Relationship between climatic factors and the flea index of two plague hosts in Xilingol League, Inner Mongolia Autonomous Region Automated robot and artificial intelligence-powered wastewater surveillance for proactive mpox outbreak prediction The differential effects of integrase strand transfer inhibitors and efavirenz on neuropsychiatric conditions and brain imaging in HIV-positive men who have sex with men
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1