不同掺杂导电聚合物对电子鼻响应主成分的稳态与动态贡献

Wiem Haj Ammar, Aicha Boujnah, Aimen Boubaker, Adel Kalboussi, Kamal Lmimouni, Sébastien Pecqueur
{"title":"不同掺杂导电聚合物对电子鼻响应主成分的稳态与动态贡献","authors":"Wiem Haj Ammar, Aicha Boujnah, Aimen Boubaker, Adel Kalboussi, Kamal Lmimouni, Sébastien Pecqueur","doi":"10.3390/eng4040141","DOIUrl":null,"url":null,"abstract":"Multivariate data analysis and machine learning classification have become popular tools to extract features without physical models for complex environments recognition. For electronic noses, time sampling over multiple sensing elements must be a fair compromise between a period sufficiently long to output a meaningful information pattern and sufficiently short to minimize training time for practical applications. Particularly when a reactivity’s kinetics differ from the thermodynamics in sensitive materials, finding the best compromise to get the most from the data is not obvious. Here, we investigate the influence of data acquisition to improve or alter data clustering for molecular recognition on a conducting polymer electronic nose. We found out that waiting for sensing elements to reach their steady state is not required for classification, and that reducing data acquisition down to the first dynamical information suffices to recognize molecular gases by principal component analysis with the same materials. Especially for online inference, this study shows that a good sensing array is not an array of good sensors, and that new figures of merit should be defined for sensing hardware using machine learning pattern recognition rather than metrology.","PeriodicalId":10630,"journal":{"name":"Comput. Chem. Eng.","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Steady vs. Dynamic Contributions of Different Doped Conducting Polymers in the Principal Components of an Electronic Nose’s Response\",\"authors\":\"Wiem Haj Ammar, Aicha Boujnah, Aimen Boubaker, Adel Kalboussi, Kamal Lmimouni, Sébastien Pecqueur\",\"doi\":\"10.3390/eng4040141\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multivariate data analysis and machine learning classification have become popular tools to extract features without physical models for complex environments recognition. For electronic noses, time sampling over multiple sensing elements must be a fair compromise between a period sufficiently long to output a meaningful information pattern and sufficiently short to minimize training time for practical applications. Particularly when a reactivity’s kinetics differ from the thermodynamics in sensitive materials, finding the best compromise to get the most from the data is not obvious. Here, we investigate the influence of data acquisition to improve or alter data clustering for molecular recognition on a conducting polymer electronic nose. We found out that waiting for sensing elements to reach their steady state is not required for classification, and that reducing data acquisition down to the first dynamical information suffices to recognize molecular gases by principal component analysis with the same materials. Especially for online inference, this study shows that a good sensing array is not an array of good sensors, and that new figures of merit should be defined for sensing hardware using machine learning pattern recognition rather than metrology.\",\"PeriodicalId\":10630,\"journal\":{\"name\":\"Comput. Chem. Eng.\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Comput. Chem. Eng.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/eng4040141\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comput. Chem. Eng.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/eng4040141","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

多变量数据分析和机器学习分类已经成为复杂环境识别中无需物理模型提取特征的流行工具。对于电子鼻,在多个传感元件上进行时间采样必须在足够长的时间以输出有意义的信息模式和足够短的时间以最大限度地减少实际应用的训练时间之间折衷。特别是当反应性的动力学与敏感材料的热力学不同时,找到从数据中获得最大收益的最佳折衷方案并不明显。在这里,我们研究了数据采集对改进或改变导电聚合物电子鼻分子识别数据聚类的影响。我们发现,等待传感元件达到稳定状态并不需要分类,并且将数据采集减少到第一个动态信息足以通过主成分分析识别相同材料的分子气体。特别是在在线推理方面,本研究表明,一个好的传感阵列并不是一个好的传感器阵列,并且应该使用机器学习模式识别而不是计量来定义传感硬件的新优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Steady vs. Dynamic Contributions of Different Doped Conducting Polymers in the Principal Components of an Electronic Nose’s Response
Multivariate data analysis and machine learning classification have become popular tools to extract features without physical models for complex environments recognition. For electronic noses, time sampling over multiple sensing elements must be a fair compromise between a period sufficiently long to output a meaningful information pattern and sufficiently short to minimize training time for practical applications. Particularly when a reactivity’s kinetics differ from the thermodynamics in sensitive materials, finding the best compromise to get the most from the data is not obvious. Here, we investigate the influence of data acquisition to improve or alter data clustering for molecular recognition on a conducting polymer electronic nose. We found out that waiting for sensing elements to reach their steady state is not required for classification, and that reducing data acquisition down to the first dynamical information suffices to recognize molecular gases by principal component analysis with the same materials. Especially for online inference, this study shows that a good sensing array is not an array of good sensors, and that new figures of merit should be defined for sensing hardware using machine learning pattern recognition rather than metrology.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study of the Synthesis Variables in the Preparation of CoAl2O4 Pigment Using Microwaves to Reduce Energetic Consumption Remarks on Constitutive Modeling of Granular Materials Analysis and Design Methodology of Radial Flux Surface-Mounted Permanent Magnet Synchronous Motors The Effect of High-Energy Ball Milling of Montmorillonite for Adsorptive Removal of Cesium, Strontium, and Uranium Ions from Aqueous Solution Review of Graphene-Based Materials for Tribological Engineering Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1