{"title":"高频超声联合超声在新生儿食管闭锁诊断中的应用价值","authors":"Yurong Ge, Baoyue Xu, Jing Shi, Weiwei Tang","doi":"10.4314/ahs.v23i3.63","DOIUrl":null,"url":null,"abstract":"Objective: To explore the application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia (EA) \nMethods: Seventy neonates with suspected EA who received healing in our hospital from August 2019 to April 2022 were retrospectively selected as the study subjects and their preoperative esophageal high-frequency ultrasound and ultrasound hydrography data were analysed. The diagnostic value of high-frequency ultrasound, ultrasound hydrography and combined detection in neonatal EA was analysed using intraoperative findings as the gold standard; \nResults: (1) Among the 70 children with suspected EA, 62 were confirmed to be positive and 8 were negative; 59 were positive and 11 were negative by ultrasound hydrography alone; 61 were positive and 9 were negative by high-frequency ultrasound alone; 62 were positive and 8 were negative by combined detection.(2) The accuracy of combined detection was 97.14%, which was notably different from 92.86% by high-frequency ultrasound and 84.29% by ultrasound hydrography (P < 0.05).(3) The diagnostic AUC of ultrasound hydrography, high-frequency ultrasound, and combined detection for EA was 0.6125, 0.6500, and 0.6563, respectively (P < 0.05).(4) There was no significant variation in the distance between preoperative high-frequency ultrasound, ultrasound hydrography, and intraoperative measurements of distal and proximal blind ends of type IIIA and IIIB EA esophagus (P > 0.05); \nConclusion: High frequency ultrasound and super fresh water injection angiography have good application value in the diagnosis of neonatal EA. There is no significant difference between the distance between the distal and proximal blind ends of the esophagus before and during the operation of type III EA and that during the operation of super fresh water injection angiography. However, in consideration of the risk of radiation and poisoning caused by esophagography, it is recommended that high-frequency ultrasound be selected first for diagnosis and if necessary, esophagography be supplemented for joint diagnosis. \nKeywords: High frequency ultrasound; Ultrasound angiography; Neonatal esophageal atresia; Application value.","PeriodicalId":7853,"journal":{"name":"African Health Sciences","volume":"43 1","pages":"0"},"PeriodicalIF":0.8000,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia\",\"authors\":\"Yurong Ge, Baoyue Xu, Jing Shi, Weiwei Tang\",\"doi\":\"10.4314/ahs.v23i3.63\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To explore the application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia (EA) \\nMethods: Seventy neonates with suspected EA who received healing in our hospital from August 2019 to April 2022 were retrospectively selected as the study subjects and their preoperative esophageal high-frequency ultrasound and ultrasound hydrography data were analysed. The diagnostic value of high-frequency ultrasound, ultrasound hydrography and combined detection in neonatal EA was analysed using intraoperative findings as the gold standard; \\nResults: (1) Among the 70 children with suspected EA, 62 were confirmed to be positive and 8 were negative; 59 were positive and 11 were negative by ultrasound hydrography alone; 61 were positive and 9 were negative by high-frequency ultrasound alone; 62 were positive and 8 were negative by combined detection.(2) The accuracy of combined detection was 97.14%, which was notably different from 92.86% by high-frequency ultrasound and 84.29% by ultrasound hydrography (P < 0.05).(3) The diagnostic AUC of ultrasound hydrography, high-frequency ultrasound, and combined detection for EA was 0.6125, 0.6500, and 0.6563, respectively (P < 0.05).(4) There was no significant variation in the distance between preoperative high-frequency ultrasound, ultrasound hydrography, and intraoperative measurements of distal and proximal blind ends of type IIIA and IIIB EA esophagus (P > 0.05); \\nConclusion: High frequency ultrasound and super fresh water injection angiography have good application value in the diagnosis of neonatal EA. There is no significant difference between the distance between the distal and proximal blind ends of the esophagus before and during the operation of type III EA and that during the operation of super fresh water injection angiography. However, in consideration of the risk of radiation and poisoning caused by esophagography, it is recommended that high-frequency ultrasound be selected first for diagnosis and if necessary, esophagography be supplemented for joint diagnosis. \\nKeywords: High frequency ultrasound; Ultrasound angiography; Neonatal esophageal atresia; Application value.\",\"PeriodicalId\":7853,\"journal\":{\"name\":\"African Health Sciences\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Health Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/ahs.v23i3.63\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/ahs.v23i3.63","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia
Objective: To explore the application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia (EA)
Methods: Seventy neonates with suspected EA who received healing in our hospital from August 2019 to April 2022 were retrospectively selected as the study subjects and their preoperative esophageal high-frequency ultrasound and ultrasound hydrography data were analysed. The diagnostic value of high-frequency ultrasound, ultrasound hydrography and combined detection in neonatal EA was analysed using intraoperative findings as the gold standard;
Results: (1) Among the 70 children with suspected EA, 62 were confirmed to be positive and 8 were negative; 59 were positive and 11 were negative by ultrasound hydrography alone; 61 were positive and 9 were negative by high-frequency ultrasound alone; 62 were positive and 8 were negative by combined detection.(2) The accuracy of combined detection was 97.14%, which was notably different from 92.86% by high-frequency ultrasound and 84.29% by ultrasound hydrography (P < 0.05).(3) The diagnostic AUC of ultrasound hydrography, high-frequency ultrasound, and combined detection for EA was 0.6125, 0.6500, and 0.6563, respectively (P < 0.05).(4) There was no significant variation in the distance between preoperative high-frequency ultrasound, ultrasound hydrography, and intraoperative measurements of distal and proximal blind ends of type IIIA and IIIB EA esophagus (P > 0.05);
Conclusion: High frequency ultrasound and super fresh water injection angiography have good application value in the diagnosis of neonatal EA. There is no significant difference between the distance between the distal and proximal blind ends of the esophagus before and during the operation of type III EA and that during the operation of super fresh water injection angiography. However, in consideration of the risk of radiation and poisoning caused by esophagography, it is recommended that high-frequency ultrasound be selected first for diagnosis and if necessary, esophagography be supplemented for joint diagnosis.
Keywords: High frequency ultrasound; Ultrasound angiography; Neonatal esophageal atresia; Application value.
期刊介绍:
The African Health Sciences is an internationally refereed journal publishing original articles on research, clinical practice, public health, policy, planning, implementation and evaluation, in the health and related sciences relevant to Africa and the tropics. Its objectives are to: Advocate for and promote the growth of reading culture in sub Saharan Africa; Provide a high quality journal in which health and policy and other researchers and practitioners in the region can and world wide, can publish their work; Promote relevant health system research and publication in the region including alternative means of health care financing, the burden of and solution of health problems in marginalized urban and rural communities amongst the displaced and others affected by conflict; Promote research and the systematic collection and collation and publication of data on diseases and conditions of equity and influence; Promote development of evidence-based policies and guidelines for clinical, public health and other practitioners. African Health Sciences acknowledges support provided by the African Health Journals Partnership Project that is funded by the US National Institutes of Health (through the National Library of Medicine and the Fogarty International Center) and facilitated by the Council of Science Editors.