Murat Canpolat, Çagri Sakalar, Serhat Bozkurt, Ahmet Yilmaz Çoban, Deniz Karaçayli, Emre Toker
{"title":"电风扇加热器在冬季机载SARS-CoV-2的热灭活及确保所有空气通过风扇的条件","authors":"Murat Canpolat, Çagri Sakalar, Serhat Bozkurt, Ahmet Yilmaz Çoban, Deniz Karaçayli, Emre Toker","doi":"10.1115/1.4063911","DOIUrl":null,"url":null,"abstract":"Abstract The way the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spread, especially in closed environments, is airborne transmission. The study aims to assess the thermal inactivation of airborne SARS-CoV-2 in a 30 m3 test room as a function of outlet temperature, airflow rate, and operating time of an electric heater, then define a condition to ensure that all air in the room passes through the electric heater. Aerosolized SARS-CoV-2 was delivered to the test room at an ambient temperature of 20 C and 40% humidity. Two electric heaters with different power and airflow rates were operated respectively in the test room to compare their efficiencies in the inactivation of airborne SARS-CoV-2. The first and second electric heaters had power, airflow rates, and outlet temperatures of 1.5 kW, 44 m3/h, 220 °C, and 3 kW, 324 m3/h, and 150 °C, respectively. A fan drew the outside air into the heater. In the first experiment, a 1.5 kW electric heater was operated in the test room for 80 minutes. In the second experiment, a 3 kW electric heater was used in the test room for 75 minutes. Airborne SARS-CoV-2 in the test room was inactivated by 99.00% and 99.96% in the first and second experiments, respectively. A condition is defined to ensure that all the air in the room passes at least once through the electric heater fan.","PeriodicalId":17404,"journal":{"name":"Journal of Thermal Science and Engineering Applications","volume":"21 4","pages":"0"},"PeriodicalIF":1.6000,"publicationDate":"2023-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal Inactivation of Airborne SARS-CoV-2 by an Electric Fan Heater in Winter and Defining Conditions to Ensure That All the Air Passes through the Fan\",\"authors\":\"Murat Canpolat, Çagri Sakalar, Serhat Bozkurt, Ahmet Yilmaz Çoban, Deniz Karaçayli, Emre Toker\",\"doi\":\"10.1115/1.4063911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The way the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spread, especially in closed environments, is airborne transmission. The study aims to assess the thermal inactivation of airborne SARS-CoV-2 in a 30 m3 test room as a function of outlet temperature, airflow rate, and operating time of an electric heater, then define a condition to ensure that all air in the room passes through the electric heater. Aerosolized SARS-CoV-2 was delivered to the test room at an ambient temperature of 20 C and 40% humidity. Two electric heaters with different power and airflow rates were operated respectively in the test room to compare their efficiencies in the inactivation of airborne SARS-CoV-2. The first and second electric heaters had power, airflow rates, and outlet temperatures of 1.5 kW, 44 m3/h, 220 °C, and 3 kW, 324 m3/h, and 150 °C, respectively. A fan drew the outside air into the heater. In the first experiment, a 1.5 kW electric heater was operated in the test room for 80 minutes. In the second experiment, a 3 kW electric heater was used in the test room for 75 minutes. Airborne SARS-CoV-2 in the test room was inactivated by 99.00% and 99.96% in the first and second experiments, respectively. A condition is defined to ensure that all the air in the room passes at least once through the electric heater fan.\",\"PeriodicalId\":17404,\"journal\":{\"name\":\"Journal of Thermal Science and Engineering Applications\",\"volume\":\"21 4\",\"pages\":\"0\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Science and Engineering Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063911\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Science and Engineering Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063911","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Thermal Inactivation of Airborne SARS-CoV-2 by an Electric Fan Heater in Winter and Defining Conditions to Ensure That All the Air Passes through the Fan
Abstract The way the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spread, especially in closed environments, is airborne transmission. The study aims to assess the thermal inactivation of airborne SARS-CoV-2 in a 30 m3 test room as a function of outlet temperature, airflow rate, and operating time of an electric heater, then define a condition to ensure that all air in the room passes through the electric heater. Aerosolized SARS-CoV-2 was delivered to the test room at an ambient temperature of 20 C and 40% humidity. Two electric heaters with different power and airflow rates were operated respectively in the test room to compare their efficiencies in the inactivation of airborne SARS-CoV-2. The first and second electric heaters had power, airflow rates, and outlet temperatures of 1.5 kW, 44 m3/h, 220 °C, and 3 kW, 324 m3/h, and 150 °C, respectively. A fan drew the outside air into the heater. In the first experiment, a 1.5 kW electric heater was operated in the test room for 80 minutes. In the second experiment, a 3 kW electric heater was used in the test room for 75 minutes. Airborne SARS-CoV-2 in the test room was inactivated by 99.00% and 99.96% in the first and second experiments, respectively. A condition is defined to ensure that all the air in the room passes at least once through the electric heater fan.
期刊介绍:
Applications in: Aerospace systems; Gas turbines; Biotechnology; Defense systems; Electronic and photonic equipment; Energy systems; Manufacturing; Refrigeration and air conditioning; Homeland security systems; Micro- and nanoscale devices; Petrochemical processing; Medical systems; Energy efficiency; Sustainability; Solar systems; Combustion systems