新型折叠流管改善塔式熔盐太阳能接收器的传热性能

IF 1.6 4区 工程技术 Q3 ENGINEERING, MECHANICAL Journal of Thermal Science and Engineering Applications Pub Date : 2023-10-27 DOI:10.1115/1.4063912
Yun Liu, Wenzhao Wang, Chuanzhi Zhang, Tao Li, Xu Zhao
{"title":"新型折叠流管改善塔式熔盐太阳能接收器的传热性能","authors":"Yun Liu, Wenzhao Wang, Chuanzhi Zhang, Tao Li, Xu Zhao","doi":"10.1115/1.4063912","DOIUrl":null,"url":null,"abstract":"Abstract The molten salt has been widely used in concentrated solar power generation as an effective high-temperature heat transfer and heat storage working fluid. However, due to the concentrating characteristic of tower receiver, the solar flux distribution of molten salt receiver is extremely non-uniform, and thus the circumferential non-uniform heat flux has a prominent effect on the heat transfer performance and reliability of traditional solar molten salt receiver tube (TRT). In this contribution, in order to solve above problems, we propose some novel folded flow tubes (NFTs), which add a partition in the tube and seal the top with end cap so that the inflow and outflow of the fluid can only proceed from the same cross-section. Then, we apply the binary nitrate (solar salt) as heat transfer fluid, which is a mixture of 60% sodium nitrate and 40% potassium nitrate. Firstly, we analyze some effects such as flow parameters, structure and heat flux loading direction on the convective heat transfer performance of the NFTs. The results show that the circumferential temperature difference of NFTs is about 17 ~ 92k lower than that of TRT, and the molten salt temperature distribution is more uniform accordingly. Moreover, the heat transfer coefficient is increased about 88.37% ∼ 122.85%, which can provide a guidance for the structural optimization of practical solar molten salt receivers to improve the heat transfer performance and reliability.","PeriodicalId":17404,"journal":{"name":"Journal of Thermal Science and Engineering Applications","volume":"54 2","pages":"0"},"PeriodicalIF":1.6000,"publicationDate":"2023-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving the heat transfer performance of the tower molten salt solar receiver with the novel folded flow tubes\",\"authors\":\"Yun Liu, Wenzhao Wang, Chuanzhi Zhang, Tao Li, Xu Zhao\",\"doi\":\"10.1115/1.4063912\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The molten salt has been widely used in concentrated solar power generation as an effective high-temperature heat transfer and heat storage working fluid. However, due to the concentrating characteristic of tower receiver, the solar flux distribution of molten salt receiver is extremely non-uniform, and thus the circumferential non-uniform heat flux has a prominent effect on the heat transfer performance and reliability of traditional solar molten salt receiver tube (TRT). In this contribution, in order to solve above problems, we propose some novel folded flow tubes (NFTs), which add a partition in the tube and seal the top with end cap so that the inflow and outflow of the fluid can only proceed from the same cross-section. Then, we apply the binary nitrate (solar salt) as heat transfer fluid, which is a mixture of 60% sodium nitrate and 40% potassium nitrate. Firstly, we analyze some effects such as flow parameters, structure and heat flux loading direction on the convective heat transfer performance of the NFTs. The results show that the circumferential temperature difference of NFTs is about 17 ~ 92k lower than that of TRT, and the molten salt temperature distribution is more uniform accordingly. Moreover, the heat transfer coefficient is increased about 88.37% ∼ 122.85%, which can provide a guidance for the structural optimization of practical solar molten salt receivers to improve the heat transfer performance and reliability.\",\"PeriodicalId\":17404,\"journal\":{\"name\":\"Journal of Thermal Science and Engineering Applications\",\"volume\":\"54 2\",\"pages\":\"0\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Science and Engineering Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063912\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Science and Engineering Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063912","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要熔盐作为一种有效的高温传热蓄热工质在聚光太阳能发电中得到了广泛的应用。然而,由于塔式接收器的聚光特性,熔盐接收器的太阳通量分布极不均匀,因此周向不均匀热流密度对传统太阳能熔盐接收管(TRT)的传热性能和可靠性影响突出。在本文中,为了解决上述问题,我们提出了一些新型的折叠流管(nft),它在管中增加隔板,并用端盖密封顶部,使流体的流入和流出只能从同一截面进行。然后,我们采用60%硝酸钠和40%硝酸钾的混合物二元硝酸盐(太阳盐)作为传热流体。首先,分析了流动参数、结构、热流载荷方向等因素对nft对流换热性能的影响。结果表明:nft的周向温差比TRT小17 ~ 92k,熔盐温度分布更加均匀;传热系数提高了约88.37% ~ 122.85%,可为实际太阳能熔盐接收器的结构优化提供指导,以提高传热性能和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improving the heat transfer performance of the tower molten salt solar receiver with the novel folded flow tubes
Abstract The molten salt has been widely used in concentrated solar power generation as an effective high-temperature heat transfer and heat storage working fluid. However, due to the concentrating characteristic of tower receiver, the solar flux distribution of molten salt receiver is extremely non-uniform, and thus the circumferential non-uniform heat flux has a prominent effect on the heat transfer performance and reliability of traditional solar molten salt receiver tube (TRT). In this contribution, in order to solve above problems, we propose some novel folded flow tubes (NFTs), which add a partition in the tube and seal the top with end cap so that the inflow and outflow of the fluid can only proceed from the same cross-section. Then, we apply the binary nitrate (solar salt) as heat transfer fluid, which is a mixture of 60% sodium nitrate and 40% potassium nitrate. Firstly, we analyze some effects such as flow parameters, structure and heat flux loading direction on the convective heat transfer performance of the NFTs. The results show that the circumferential temperature difference of NFTs is about 17 ~ 92k lower than that of TRT, and the molten salt temperature distribution is more uniform accordingly. Moreover, the heat transfer coefficient is increased about 88.37% ∼ 122.85%, which can provide a guidance for the structural optimization of practical solar molten salt receivers to improve the heat transfer performance and reliability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Thermal Science and Engineering Applications
Journal of Thermal Science and Engineering Applications THERMODYNAMICSENGINEERING, MECHANICAL -ENGINEERING, MECHANICAL
CiteScore
3.60
自引率
9.50%
发文量
120
期刊介绍: Applications in: Aerospace systems; Gas turbines; Biotechnology; Defense systems; Electronic and photonic equipment; Energy systems; Manufacturing; Refrigeration and air conditioning; Homeland security systems; Micro- and nanoscale devices; Petrochemical processing; Medical systems; Energy efficiency; Sustainability; Solar systems; Combustion systems
期刊最新文献
Improving turbine endwall overall cooling effectiveness using curtain cooling and redistributed film-hole layouts: an experimental and computational study Soft Computing Model for Inverse Prediction of Surface Heat Flux from Temperature Responses in Short-Duration Heat Transfer Experiments Aerothermal Optimization of Film Cooling Hole Locations on the Squealer Tip of an HP Turbine Blade Theoretical investigation of low global warming potential blends replacing R404A: the simple refrigeration cycle and its modifications Study on the Influence of Fan and Fan Cowl on Intake Air Parameters of Cooling Module
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1