{"title":"基于实弱值弱测量的时延精度估计","authors":"Weining Liu, Yisen Wang, Hailu Luo","doi":"10.1103/physreva.108.052606","DOIUrl":null,"url":null,"abstract":"In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.","PeriodicalId":20121,"journal":{"name":"Physical Review","volume":"52 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precision estimation of time delay based on weak measurement with real weak value\",\"authors\":\"Weining Liu, Yisen Wang, Hailu Luo\",\"doi\":\"10.1103/physreva.108.052606\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.\",\"PeriodicalId\":20121,\"journal\":{\"name\":\"Physical Review\",\"volume\":\"52 8\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1103/physreva.108.052606\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1103/physreva.108.052606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Precision estimation of time delay based on weak measurement with real weak value
In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.