集成电容器失效分析的复杂性

Christopher S. Mahinay, Christian Reyes, Ricardo Calanog, Raymond Mendaros
{"title":"集成电容器失效分析的复杂性","authors":"Christopher S. Mahinay, Christian Reyes, Ricardo Calanog, Raymond Mendaros","doi":"10.31399/asm.cp.istfa2023p0045","DOIUrl":null,"url":null,"abstract":"Abstract Integrated capacitors use metal plates such as in Metal-Insulator-Metal (MIM) and Metal-Oxide-Metal (MOM) capacitors while Polysilicon and Silicon (Si) substrate for metal-oxide-semiconductor (MOS) capacitors. Three major challenges and solutions were discussed in this technical paper. First, the failure site localization of a subtle defect in the capacitor plates. To determine the specific location of the defect site, Electron Beam Induced Current (EBIC) analysis was performed while the part was biased using a nano-probe set-up under Scanning Electron Microscopy (SEM) environment. Second, Failure Mechanism contentions between Electrically Induced Physical Damage (EIPD) or Fabrication process defect particularly, for damage site that is not at the edge of the capacitor and without obvious manifestations of Fabrication process anomalies such as bulging, void, unetched material or shifts in the planarity of the die layers. To further understand the defect site, Scanning Transmission Electron Microscopy (STEM) coupled with Energy-Dispersive X-ray Spectroscopy (EDS) were utilized to obtain high magnification imaging and elemental area mapping. Third, misled conclusion to be an EIPD site manifested by burnt and reflowed metallization. The EIPD site was only a secondary effect of a capacitor dielectric breakdown. This has been uncovered after understanding the circuit connectivity, inspections of the capacitors connected to the EIPD site, fault isolation and further physical failure analysis were performed. As results of the Failure Analysis (FA), Customer and Analog Devices Incorporated (ADI) manufacturing hold lots were accurately dispositioned and related corrective actions were precisely identified and implemented.","PeriodicalId":20443,"journal":{"name":"Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intricacies in the Failure Analysis of Integrated Capacitors\",\"authors\":\"Christopher S. Mahinay, Christian Reyes, Ricardo Calanog, Raymond Mendaros\",\"doi\":\"10.31399/asm.cp.istfa2023p0045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Integrated capacitors use metal plates such as in Metal-Insulator-Metal (MIM) and Metal-Oxide-Metal (MOM) capacitors while Polysilicon and Silicon (Si) substrate for metal-oxide-semiconductor (MOS) capacitors. Three major challenges and solutions were discussed in this technical paper. First, the failure site localization of a subtle defect in the capacitor plates. To determine the specific location of the defect site, Electron Beam Induced Current (EBIC) analysis was performed while the part was biased using a nano-probe set-up under Scanning Electron Microscopy (SEM) environment. Second, Failure Mechanism contentions between Electrically Induced Physical Damage (EIPD) or Fabrication process defect particularly, for damage site that is not at the edge of the capacitor and without obvious manifestations of Fabrication process anomalies such as bulging, void, unetched material or shifts in the planarity of the die layers. To further understand the defect site, Scanning Transmission Electron Microscopy (STEM) coupled with Energy-Dispersive X-ray Spectroscopy (EDS) were utilized to obtain high magnification imaging and elemental area mapping. Third, misled conclusion to be an EIPD site manifested by burnt and reflowed metallization. The EIPD site was only a secondary effect of a capacitor dielectric breakdown. This has been uncovered after understanding the circuit connectivity, inspections of the capacitors connected to the EIPD site, fault isolation and further physical failure analysis were performed. As results of the Failure Analysis (FA), Customer and Analog Devices Incorporated (ADI) manufacturing hold lots were accurately dispositioned and related corrective actions were precisely identified and implemented.\",\"PeriodicalId\":20443,\"journal\":{\"name\":\"Proceedings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31399/asm.cp.istfa2023p0045\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.cp.istfa2023p0045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

集成电容器采用金属极板,如金属-绝缘体-金属(MIM)和金属-氧化物-金属(MOM)电容器,而金属-氧化物-半导体(MOS)电容器采用多晶硅和硅(Si)衬底。本文讨论了三个主要挑战和解决方案。首先,电容极板中细微缺陷的故障位置定位。为了确定缺陷部位的具体位置,在扫描电子显微镜(SEM)环境下,使用纳米探针设置偏置零件进行电子束感应电流(EBIC)分析。其次,电致物理损伤(EIPD)或制造工艺缺陷之间的失效机制争论,特别是对于不在电容器边缘的损坏部位,并且没有明显的制造工艺异常表现,如鼓胀,空洞,未蚀刻材料或模具层平面度的变化。为了进一步了解缺陷部位,利用扫描透射电子显微镜(STEM)和能量色散x射线能谱(EDS)进行高倍成像和元素面积测绘。第三,被误导的结论是一个EIPD现场表现为烧和回流金属化。EIPD位点只是电容器介电击穿的二次效应。在了解电路连接、检查连接到EIPD站点的电容器、进行故障隔离和进一步的物理故障分析之后,发现了这一点。由于失效分析(FA)的结果,客户和ADI公司的制造保留批次被准确地定位,相关的纠正措施被精确地识别和实施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intricacies in the Failure Analysis of Integrated Capacitors
Abstract Integrated capacitors use metal plates such as in Metal-Insulator-Metal (MIM) and Metal-Oxide-Metal (MOM) capacitors while Polysilicon and Silicon (Si) substrate for metal-oxide-semiconductor (MOS) capacitors. Three major challenges and solutions were discussed in this technical paper. First, the failure site localization of a subtle defect in the capacitor plates. To determine the specific location of the defect site, Electron Beam Induced Current (EBIC) analysis was performed while the part was biased using a nano-probe set-up under Scanning Electron Microscopy (SEM) environment. Second, Failure Mechanism contentions between Electrically Induced Physical Damage (EIPD) or Fabrication process defect particularly, for damage site that is not at the edge of the capacitor and without obvious manifestations of Fabrication process anomalies such as bulging, void, unetched material or shifts in the planarity of the die layers. To further understand the defect site, Scanning Transmission Electron Microscopy (STEM) coupled with Energy-Dispersive X-ray Spectroscopy (EDS) were utilized to obtain high magnification imaging and elemental area mapping. Third, misled conclusion to be an EIPD site manifested by burnt and reflowed metallization. The EIPD site was only a secondary effect of a capacitor dielectric breakdown. This has been uncovered after understanding the circuit connectivity, inspections of the capacitors connected to the EIPD site, fault isolation and further physical failure analysis were performed. As results of the Failure Analysis (FA), Customer and Analog Devices Incorporated (ADI) manufacturing hold lots were accurately dispositioned and related corrective actions were precisely identified and implemented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1
审稿时长
11 weeks
期刊最新文献
Prevalence of Secondary Hyperparathyroidism in Hemo- Dialysis Patients Mean Rise in Hemoglobin After Intravenous Iron Therapy in Children with Iron Deficiency Anemia Mean Rise in Hemoglobin After Intravenous Iron Therapy in Children with Iron Deficiency Anemia Estimation of Rotavirus Associated Diarrheal Disease Burden Amongst Primary School Children of Sindh Functional Outcome of Shaft of Femur Fracture Fixation with Elastic Nail in Children Between 05 to 10 Years of Age
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1