在溶液中实现空间分辨单分子检测的步骤

H P Mathis, G Kalusche, B Wagner, J S McCaskill
{"title":"在溶液中实现空间分辨单分子检测的步骤","authors":"H P Mathis,&nbsp;G Kalusche,&nbsp;B Wagner,&nbsp;J S McCaskill","doi":"10.1002/1361-6374(199709)5:3<116::AID-BIO5>3.0.CO;2-J","DOIUrl":null,"url":null,"abstract":"<p>Spatially resolved single molecule detection in solution is a prerequisite for molecule tracking and provides new opportunities in single molecule manipulation, for example in a sample flow. A detector with fast timing properties and high spatial resolution is required for these purposes. We introduce a concept for spatially resolved optical single molecule detection in an epi-illuminated microscope using a novel kind of detector and a new algorithm in configurable hardware for intelligent data processing. The analysis is performed on a parallel hardware interface and includes burst detection. It can be extended to <i>on-line</i> spatial and temporal data analysis. This detector will be used in combination with a molecular sorter where molecules are sorted in a microstructured flow device made of silicon. In a first step towards such sorting in these microstructures, we show that a reliable detection of single molecules in silicon microstructures is possible in zero-dimensional detection volumes. The noise structure of the data is analysed in terms of Poissonian statistics and it is shown that in the smallest structure used (depth 20 μm) a signal-to-noise ratio of 40 is achieved.</p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2001-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199709)5:3<116::AID-BIO5>3.0.CO;2-J","citationCount":"0","resultStr":"{\"title\":\"Steps towards spatially resolved single molecule detection in solution\",\"authors\":\"H P Mathis,&nbsp;G Kalusche,&nbsp;B Wagner,&nbsp;J S McCaskill\",\"doi\":\"10.1002/1361-6374(199709)5:3<116::AID-BIO5>3.0.CO;2-J\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Spatially resolved single molecule detection in solution is a prerequisite for molecule tracking and provides new opportunities in single molecule manipulation, for example in a sample flow. A detector with fast timing properties and high spatial resolution is required for these purposes. We introduce a concept for spatially resolved optical single molecule detection in an epi-illuminated microscope using a novel kind of detector and a new algorithm in configurable hardware for intelligent data processing. The analysis is performed on a parallel hardware interface and includes burst detection. It can be extended to <i>on-line</i> spatial and temporal data analysis. This detector will be used in combination with a molecular sorter where molecules are sorted in a microstructured flow device made of silicon. In a first step towards such sorting in these microstructures, we show that a reliable detection of single molecules in silicon microstructures is possible in zero-dimensional detection volumes. The noise structure of the data is analysed in terms of Poissonian statistics and it is shown that in the smallest structure used (depth 20 μm) a signal-to-noise ratio of 40 is achieved.</p>\",\"PeriodicalId\":100176,\"journal\":{\"name\":\"Bioimaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/1361-6374(199709)5:3<116::AID-BIO5>3.0.CO;2-J\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioimaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/1361-6374%28199709%295%3A3%3C116%3A%3AAID-BIO5%3E3.0.CO%3B2-J\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioimaging","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1361-6374%28199709%295%3A3%3C116%3A%3AAID-BIO5%3E3.0.CO%3B2-J","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

溶液中的空间分辨单分子检测是分子跟踪的先决条件,并为单分子操作提供了新的机会,例如在样品流中。为此,需要一种具有快速定时特性和高空间分辨率的探测器。我们提出了一种利用新型检测器和可配置硬件进行智能数据处理的新算法在外延发光显微镜中进行空间分辨光学单分子检测的概念。分析是在并行硬件接口上进行的,包括突发检测。它可以扩展到在线时空数据分析。该探测器将与分子分选器结合使用,分子在硅制成的微结构流动装置中进行分选。在这些微结构中进行这种分选的第一步,我们表明可以在零维检测体积中可靠地检测硅微结构中的单分子。根据泊松统计分析了数据的噪声结构,结果表明,在最小的结构(深度为20 μm)中,信噪比达到40。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Steps towards spatially resolved single molecule detection in solution

Spatially resolved single molecule detection in solution is a prerequisite for molecule tracking and provides new opportunities in single molecule manipulation, for example in a sample flow. A detector with fast timing properties and high spatial resolution is required for these purposes. We introduce a concept for spatially resolved optical single molecule detection in an epi-illuminated microscope using a novel kind of detector and a new algorithm in configurable hardware for intelligent data processing. The analysis is performed on a parallel hardware interface and includes burst detection. It can be extended to on-line spatial and temporal data analysis. This detector will be used in combination with a molecular sorter where molecules are sorted in a microstructured flow device made of silicon. In a first step towards such sorting in these microstructures, we show that a reliable detection of single molecules in silicon microstructures is possible in zero-dimensional detection volumes. The noise structure of the data is analysed in terms of Poissonian statistics and it is shown that in the smallest structure used (depth 20 μm) a signal-to-noise ratio of 40 is achieved.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Magnetic Particle Imaging Magnetic Resonance Imaging Quantitative evaluation of light microscopes based on image processing techniques Confocal microscopy of single molecules of the green fluorescent protein Heavy metal contrast enhancement for the selective detection of gold particles in electron microscopical sections using electron spectroscopic imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1