Ida Sjöberg, Ellen Law, Fredrik Södersten, Odd Viking Höglund, Ove Wattle
{"title":"对马皮下组织对3D打印聚二氧环酮装置反应的初步调查。","authors":"Ida Sjöberg, Ellen Law, Fredrik Södersten, Odd Viking Höglund, Ove Wattle","doi":"10.1186/s13028-023-00710-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination.</p><p><strong>Results: </strong>On macroscopic inspection at day 10, the PDO-device was fragmented and the surrounding tissue was oedematous. On ultrasonographic examination, the device was seen as a hyperechoic structure with strong acoustic shadowing that could be detected 4 months post-implantation, but not at 7 months. Histology revealed a transient granulomatous inflammation, i.e., a foreign body reaction, which surrounded both PDO and PLGA implants. The type and intensity of the inflammation varied between individuals and tissue category.</p><p><strong>Conclusions: </strong>The 3D printed PDO-device caused a transient inflammatory reaction in the subcutaneous tissue and complete resorption occurred between 4 and 7 months. Considering the intended use as a ligation device the early fragmentation warrants further adjustments of both material and the 3D printing process before the device can be used in a clinical setting.</p>","PeriodicalId":7181,"journal":{"name":"Acta Veterinaria Scandinavica","volume":"65 1","pages":"48"},"PeriodicalIF":1.9000,"publicationDate":"2023-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659009/pdf/","citationCount":"0","resultStr":"{\"title\":\"A preliminary investigation of the subcutaneous tissue reaction to a 3D printed polydioxanone device in horses.\",\"authors\":\"Ida Sjöberg, Ellen Law, Fredrik Södersten, Odd Viking Höglund, Ove Wattle\",\"doi\":\"10.1186/s13028-023-00710-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination.</p><p><strong>Results: </strong>On macroscopic inspection at day 10, the PDO-device was fragmented and the surrounding tissue was oedematous. On ultrasonographic examination, the device was seen as a hyperechoic structure with strong acoustic shadowing that could be detected 4 months post-implantation, but not at 7 months. Histology revealed a transient granulomatous inflammation, i.e., a foreign body reaction, which surrounded both PDO and PLGA implants. The type and intensity of the inflammation varied between individuals and tissue category.</p><p><strong>Conclusions: </strong>The 3D printed PDO-device caused a transient inflammatory reaction in the subcutaneous tissue and complete resorption occurred between 4 and 7 months. Considering the intended use as a ligation device the early fragmentation warrants further adjustments of both material and the 3D printing process before the device can be used in a clinical setting.</p>\",\"PeriodicalId\":7181,\"journal\":{\"name\":\"Acta Veterinaria Scandinavica\",\"volume\":\"65 1\",\"pages\":\"48\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2023-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659009/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Veterinaria Scandinavica\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1186/s13028-023-00710-0\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Veterinaria Scandinavica","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1186/s13028-023-00710-0","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
A preliminary investigation of the subcutaneous tissue reaction to a 3D printed polydioxanone device in horses.
Background: A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination.
Results: On macroscopic inspection at day 10, the PDO-device was fragmented and the surrounding tissue was oedematous. On ultrasonographic examination, the device was seen as a hyperechoic structure with strong acoustic shadowing that could be detected 4 months post-implantation, but not at 7 months. Histology revealed a transient granulomatous inflammation, i.e., a foreign body reaction, which surrounded both PDO and PLGA implants. The type and intensity of the inflammation varied between individuals and tissue category.
Conclusions: The 3D printed PDO-device caused a transient inflammatory reaction in the subcutaneous tissue and complete resorption occurred between 4 and 7 months. Considering the intended use as a ligation device the early fragmentation warrants further adjustments of both material and the 3D printing process before the device can be used in a clinical setting.
期刊介绍:
Acta Veterinaria Scandinavica is an open access journal encompassing all aspects of veterinary research and medicine of domestic and wild animals.