{"title":"聚合物浸润陶瓷网络与二硅酸锂种植体混合基冠在美观区牙冠骨损失和牙周参数的评估(一项随机临床试验)","authors":"Inas Adel Mahmoud MSc, PhD, Adel Mohamed ElTannir MSc, PhD, Sherihan Mohamed Eissa MSc, PhD, Reham Said ElBasty MSc, PhD","doi":"10.1111/cid.13293","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Lithium disilicate can be reliable when restoring implants in the esthetic zone. However, it has a high elastic modulus. This might increase the amount of forces transmitted to the crestal bone.</p>\n </section>\n \n <section>\n \n <h3> Aim of the Study</h3>\n \n <p>To evaluate the crestal bone loss and peri-implant periodontal parameters of polymer infiltrated ceramic network compared to lithium disilicate implant-supported hybrid abutment crowns after 12 months of follow-up.</p>\n </section>\n \n <section>\n \n <h3> Methodology</h3>\n \n <p>44 patients were enrolled. They were randomly assigned into two groups (<i>n</i> = 22). The first group received 22 implants restored with polymer-infiltrated ceramic network (Vitaenamic) hybrid abutment crowns. The second group received 22 implants restored with lithium disilicate (e.max) hybrid abutment crowns over immediately placed implants in the esthetic zone. Periapical radiographs were taken immediately after prosthetic placement and 1 year later utilizing a parallel technique, to assess crestal bone loss. Periodontal parameters were assessed after 1 year.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Regarding crestal bone loss, a comparison between group I (Vitaenamic) and group II (e.max) was made by using an Independent t-test, which showed an insignificant difference between them (<i>p</i> > 0.05). A comparison between groups I and II revealed insignificant differences regarding periodontal parameters (probing depth, bleeding on probing, visible plaque, and suppuration).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Regarding bone stability and periodontal parameters, polymer infiltrated ceramic network and lithium disilicate hybrid abutment crowns showed comparable results. Both materials showed clinically acceptable hard and soft tissue responses.</p>\n </section>\n </div>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"26 2","pages":"333-342"},"PeriodicalIF":3.7000,"publicationDate":"2023-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of crestal bone loss and periodontal parameters of polymer infiltrated ceramic network versus lithium disilicate implant hybrid abutment crowns in the esthetic zone (A randomized clinical trial)\",\"authors\":\"Inas Adel Mahmoud MSc, PhD, Adel Mohamed ElTannir MSc, PhD, Sherihan Mohamed Eissa MSc, PhD, Reham Said ElBasty MSc, PhD\",\"doi\":\"10.1111/cid.13293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Lithium disilicate can be reliable when restoring implants in the esthetic zone. However, it has a high elastic modulus. This might increase the amount of forces transmitted to the crestal bone.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Aim of the Study</h3>\\n \\n <p>To evaluate the crestal bone loss and peri-implant periodontal parameters of polymer infiltrated ceramic network compared to lithium disilicate implant-supported hybrid abutment crowns after 12 months of follow-up.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methodology</h3>\\n \\n <p>44 patients were enrolled. They were randomly assigned into two groups (<i>n</i> = 22). The first group received 22 implants restored with polymer-infiltrated ceramic network (Vitaenamic) hybrid abutment crowns. The second group received 22 implants restored with lithium disilicate (e.max) hybrid abutment crowns over immediately placed implants in the esthetic zone. Periapical radiographs were taken immediately after prosthetic placement and 1 year later utilizing a parallel technique, to assess crestal bone loss. Periodontal parameters were assessed after 1 year.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Regarding crestal bone loss, a comparison between group I (Vitaenamic) and group II (e.max) was made by using an Independent t-test, which showed an insignificant difference between them (<i>p</i> > 0.05). A comparison between groups I and II revealed insignificant differences regarding periodontal parameters (probing depth, bleeding on probing, visible plaque, and suppuration).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Regarding bone stability and periodontal parameters, polymer infiltrated ceramic network and lithium disilicate hybrid abutment crowns showed comparable results. Both materials showed clinically acceptable hard and soft tissue responses.</p>\\n </section>\\n </div>\",\"PeriodicalId\":50679,\"journal\":{\"name\":\"Clinical Implant Dentistry and Related Research\",\"volume\":\"26 2\",\"pages\":\"333-342\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Implant Dentistry and Related Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/cid.13293\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.13293","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Assessment of crestal bone loss and periodontal parameters of polymer infiltrated ceramic network versus lithium disilicate implant hybrid abutment crowns in the esthetic zone (A randomized clinical trial)
Background
Lithium disilicate can be reliable when restoring implants in the esthetic zone. However, it has a high elastic modulus. This might increase the amount of forces transmitted to the crestal bone.
Aim of the Study
To evaluate the crestal bone loss and peri-implant periodontal parameters of polymer infiltrated ceramic network compared to lithium disilicate implant-supported hybrid abutment crowns after 12 months of follow-up.
Methodology
44 patients were enrolled. They were randomly assigned into two groups (n = 22). The first group received 22 implants restored with polymer-infiltrated ceramic network (Vitaenamic) hybrid abutment crowns. The second group received 22 implants restored with lithium disilicate (e.max) hybrid abutment crowns over immediately placed implants in the esthetic zone. Periapical radiographs were taken immediately after prosthetic placement and 1 year later utilizing a parallel technique, to assess crestal bone loss. Periodontal parameters were assessed after 1 year.
Results
Regarding crestal bone loss, a comparison between group I (Vitaenamic) and group II (e.max) was made by using an Independent t-test, which showed an insignificant difference between them (p > 0.05). A comparison between groups I and II revealed insignificant differences regarding periodontal parameters (probing depth, bleeding on probing, visible plaque, and suppuration).
Conclusions
Regarding bone stability and periodontal parameters, polymer infiltrated ceramic network and lithium disilicate hybrid abutment crowns showed comparable results. Both materials showed clinically acceptable hard and soft tissue responses.
期刊介绍:
The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal.
The range of topics covered by the journals will include but be not limited to:
New scientific developments relating to bone
Implant surfaces and their relationship to the surrounding tissues
Computer aided implant designs
Computer aided prosthetic designs
Immediate implant loading
Immediate implant placement
Materials relating to bone induction and conduction
New surgical methods relating to implant placement
New materials and methods relating to implant restorations
Methods for determining implant stability
A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.