引导种植理念对截骨准备和种植体放置准确性的影响。

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of oral science Pub Date : 2024-01-16 Epub Date: 2023-11-30 DOI:10.2334/josnusd.23-0157
Shruti Sharma, Emilie Tan, Britney Tran, Hui Y Siow, Elshadaie Tafesse, Yoong H J Thong, Row J M Tan, Jungwoo Son, Lisa Todaro, Josephine Teo, Jaafar Abduo
{"title":"引导种植理念对截骨准备和种植体放置准确性的影响。","authors":"Shruti Sharma, Emilie Tan, Britney Tran, Hui Y Siow, Elshadaie Tafesse, Yoong H J Thong, Row J M Tan, Jungwoo Son, Lisa Todaro, Josephine Teo, Jaafar Abduo","doi":"10.2334/josnusd.23-0157","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the accuracy of osteotomy preparation and implant placement for 3 pilot-guided (PG) concepts, namely, a surgical template with a metal sleeve (MS), a surgical template with an in-built nonmetal sleeve (NMS), and a surgical template with an in-built nonmetal sleeve for round bur indentation (RB).</p><p><strong>Methods: </strong>Surgical models with missing maxillary molars were studied. The MS templates were designed to accept metal sleeves, while the NMS and RB templates were designed with in-built nonmetal sleeves. Ten templates were tested per group (n = 10). After each step (pilot drilling, 2nd drilling, 3rd drilling, profiling, and implant placement), the surgical model was scanned and compared against the planning model to determine maximum horizontal deviation (MHD) and maximum angle deviation (MAD).</p><p><strong>Results: </strong>The MS and NMS templates exhibited a similar increase in MHD with successive drilling steps. The MAD for the pilot drilling step was significantly lower for MS than for the other groups. However, the differences among groups for MHD and MAD diminished in later steps. All templates had an MHD of 1.0 mm or less and an MAD less than 8°.</p><p><strong>Conclusion: </strong>The investigated PG implant placement concepts resulted in similar deviations in the placed implants.</p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement.\",\"authors\":\"Shruti Sharma, Emilie Tan, Britney Tran, Hui Y Siow, Elshadaie Tafesse, Yoong H J Thong, Row J M Tan, Jungwoo Son, Lisa Todaro, Josephine Teo, Jaafar Abduo\",\"doi\":\"10.2334/josnusd.23-0157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the accuracy of osteotomy preparation and implant placement for 3 pilot-guided (PG) concepts, namely, a surgical template with a metal sleeve (MS), a surgical template with an in-built nonmetal sleeve (NMS), and a surgical template with an in-built nonmetal sleeve for round bur indentation (RB).</p><p><strong>Methods: </strong>Surgical models with missing maxillary molars were studied. The MS templates were designed to accept metal sleeves, while the NMS and RB templates were designed with in-built nonmetal sleeves. Ten templates were tested per group (n = 10). After each step (pilot drilling, 2nd drilling, 3rd drilling, profiling, and implant placement), the surgical model was scanned and compared against the planning model to determine maximum horizontal deviation (MHD) and maximum angle deviation (MAD).</p><p><strong>Results: </strong>The MS and NMS templates exhibited a similar increase in MHD with successive drilling steps. The MAD for the pilot drilling step was significantly lower for MS than for the other groups. However, the differences among groups for MHD and MAD diminished in later steps. All templates had an MHD of 1.0 mm or less and an MAD less than 8°.</p><p><strong>Conclusion: </strong>The investigated PG implant placement concepts resulted in similar deviations in the placed implants.</p>\",\"PeriodicalId\":16646,\"journal\":{\"name\":\"Journal of oral science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of oral science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2334/josnusd.23-0157\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.23-0157","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价导导式(PG)三种术式的截骨准备和种植体放置的准确性,即金属套筒手术模板(MS)、内置非金属套筒手术模板(NMS)和圆形bur压痕内置非金属套筒手术模板(RB)。方法:对上颌磨牙缺失的手术模型进行研究。MS模板设计为可接受金属套筒,NMS和RB模板设计为内置非金属套筒。每组测试10个模板(n = 10)。在每个步骤(预钻孔、第二钻孔、第三钻孔、轮廓和植入物)完成后,对手术模型进行扫描,并与计划模型进行比较,以确定最大水平偏差(MHD)和最大角度偏差(MAD)。结果:MS和NMS模板的MHD随钻孔步骤的增加而增加。MS组先导钻井步骤的MAD显著低于其他组。然而,MHD和MAD组间的差异在随后的步骤中逐渐减小。所有模板的MHD小于等于1.0 mm, MAD小于8°。结论:所研究的PG种植体放置概念在放置种植体时产生了相似的偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement.

Purpose: To evaluate the accuracy of osteotomy preparation and implant placement for 3 pilot-guided (PG) concepts, namely, a surgical template with a metal sleeve (MS), a surgical template with an in-built nonmetal sleeve (NMS), and a surgical template with an in-built nonmetal sleeve for round bur indentation (RB).

Methods: Surgical models with missing maxillary molars were studied. The MS templates were designed to accept metal sleeves, while the NMS and RB templates were designed with in-built nonmetal sleeves. Ten templates were tested per group (n = 10). After each step (pilot drilling, 2nd drilling, 3rd drilling, profiling, and implant placement), the surgical model was scanned and compared against the planning model to determine maximum horizontal deviation (MHD) and maximum angle deviation (MAD).

Results: The MS and NMS templates exhibited a similar increase in MHD with successive drilling steps. The MAD for the pilot drilling step was significantly lower for MS than for the other groups. However, the differences among groups for MHD and MAD diminished in later steps. All templates had an MHD of 1.0 mm or less and an MAD less than 8°.

Conclusion: The investigated PG implant placement concepts resulted in similar deviations in the placed implants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
期刊最新文献
A micro-computed tomographic evaluation of maxillary first molar accessory root canal morphology in a Black South African subpopulation. Attitudes of general and specialist French practitioners toward stage III-IV grade C periodontitis with familial aggregation. Clinical behavior and survival of endodontically treated teeth with or without post placement: a systematic review and meta-analysis. CAD-CAM for removable partial denture fabrication after marginal mandibulectomy based on a well-adjusted pre-existing denture. Assessment of cytotoxicity, odontoblast-like differentiation, shear bond strength, and microhardness of four orthodontic adhesive composites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1