Minglei Kang, J Isabelle Choi, Kevin Souris, Jun Zhou, Gang Yu, Annemarie F Shepherd, Nitin Ohri, Stanislav Lazarev, Liyong Lin, Haibo Lin, Charles B Simone
{"title":"质子笔束扫描肺立体定向放射治疗安全性和准确性的治疗计划和管理进展:模拟、计划、质量保证和交付建议。","authors":"Minglei Kang, J Isabelle Choi, Kevin Souris, Jun Zhou, Gang Yu, Annemarie F Shepherd, Nitin Ohri, Stanislav Lazarev, Liyong Lin, Haibo Lin, Charles B Simone","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study presents the clinical experiences of the New York Proton Center in employing proton pencil beam scanning (PBS) for the treatment of lung stereotactic body radiation therapy. It encompasses a comprehensive examination of multiple facets, including patient simulation, delineation of target volumes and organs at risk, treatment planning, plan evaluation, quality assurance, and motion management strategies. By sharing the approaches of the New York Proton Center and providing recommendations across simulation, treatment planning, and treatment delivery, it is anticipated that the valuable experience will be provided to a broader proton therapy community, serving as a useful reference for future clinical practice and research endeavors in the field of stereotactic body proton therapy for lung tumors.</p>","PeriodicalId":16917,"journal":{"name":"Journal of radiosurgery and SBRT","volume":"9 1","pages":"53-62"},"PeriodicalIF":0.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681141/pdf/","citationCount":"0","resultStr":"{\"title\":\"Advances in treatment planning and management for the safety and accuracy of lung stereotactic body radiation therapy using proton pencil beam scanning: Simulation, planning, quality assurance, and delivery recommendations.\",\"authors\":\"Minglei Kang, J Isabelle Choi, Kevin Souris, Jun Zhou, Gang Yu, Annemarie F Shepherd, Nitin Ohri, Stanislav Lazarev, Liyong Lin, Haibo Lin, Charles B Simone\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study presents the clinical experiences of the New York Proton Center in employing proton pencil beam scanning (PBS) for the treatment of lung stereotactic body radiation therapy. It encompasses a comprehensive examination of multiple facets, including patient simulation, delineation of target volumes and organs at risk, treatment planning, plan evaluation, quality assurance, and motion management strategies. By sharing the approaches of the New York Proton Center and providing recommendations across simulation, treatment planning, and treatment delivery, it is anticipated that the valuable experience will be provided to a broader proton therapy community, serving as a useful reference for future clinical practice and research endeavors in the field of stereotactic body proton therapy for lung tumors.</p>\",\"PeriodicalId\":16917,\"journal\":{\"name\":\"Journal of radiosurgery and SBRT\",\"volume\":\"9 1\",\"pages\":\"53-62\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681141/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of radiosurgery and SBRT\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of radiosurgery and SBRT","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
Advances in treatment planning and management for the safety and accuracy of lung stereotactic body radiation therapy using proton pencil beam scanning: Simulation, planning, quality assurance, and delivery recommendations.
This study presents the clinical experiences of the New York Proton Center in employing proton pencil beam scanning (PBS) for the treatment of lung stereotactic body radiation therapy. It encompasses a comprehensive examination of multiple facets, including patient simulation, delineation of target volumes and organs at risk, treatment planning, plan evaluation, quality assurance, and motion management strategies. By sharing the approaches of the New York Proton Center and providing recommendations across simulation, treatment planning, and treatment delivery, it is anticipated that the valuable experience will be provided to a broader proton therapy community, serving as a useful reference for future clinical practice and research endeavors in the field of stereotactic body proton therapy for lung tumors.