增材制造的Ti-Ta-Cu合金用于下一代承重植入物。

IF 16.1 1区 工程技术 Q1 ENGINEERING, MANUFACTURING International Journal of Extreme Manufacturing Pub Date : 2024-02-01 Epub Date: 2023-11-17 DOI:10.1088/2631-7990/ad07e7
Amit Bandyopadhyay, Indranath Mitra, Sushant Ciliveri, Jose D Avila, William Dernell, Stuart B Goodman, Susmita Bose
{"title":"增材制造的Ti-Ta-Cu合金用于下一代承重植入物。","authors":"Amit Bandyopadhyay, Indranath Mitra, Sushant Ciliveri, Jose D Avila, William Dernell, Stuart B Goodman, Susmita Bose","doi":"10.1088/2631-7990/ad07e7","DOIUrl":null,"url":null,"abstract":"<p><p>Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum (Ta)-Copper (Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological, mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta (10Ta) and 3 wt.% Cu (3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against <i>Pseudomonas aeruginosa</i> and <i>Staphylococcus aureus</i> strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e. 78%-86% with respect to CpTi. Mechanical properties for Ti3Al2V-10Ta-3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. <i>In vivo</i> studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with 10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse inflammatory response <i>in vivo</i>. Our results establish the Ti3Al2V-10Ta-3Cu alloy's synergistic effect on improving both <i>in vivo</i> biocompatibility and microbial resistance for the next generation of load-bearing metallic implants.</p>","PeriodicalId":52353,"journal":{"name":"International Journal of Extreme Manufacturing","volume":null,"pages":null},"PeriodicalIF":16.1000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654690/pdf/","citationCount":"0","resultStr":"{\"title\":\"Additively manufactured Ti-Ta-Cu alloys for the next-generation load-bearing implants.\",\"authors\":\"Amit Bandyopadhyay, Indranath Mitra, Sushant Ciliveri, Jose D Avila, William Dernell, Stuart B Goodman, Susmita Bose\",\"doi\":\"10.1088/2631-7990/ad07e7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum (Ta)-Copper (Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological, mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta (10Ta) and 3 wt.% Cu (3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against <i>Pseudomonas aeruginosa</i> and <i>Staphylococcus aureus</i> strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e. 78%-86% with respect to CpTi. Mechanical properties for Ti3Al2V-10Ta-3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. <i>In vivo</i> studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with 10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse inflammatory response <i>in vivo</i>. Our results establish the Ti3Al2V-10Ta-3Cu alloy's synergistic effect on improving both <i>in vivo</i> biocompatibility and microbial resistance for the next generation of load-bearing metallic implants.</p>\",\"PeriodicalId\":52353,\"journal\":{\"name\":\"International Journal of Extreme Manufacturing\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.1000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654690/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Extreme Manufacturing\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/2631-7990/ad07e7\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MANUFACTURING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Extreme Manufacturing","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/2631-7990/ad07e7","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

摘要

细菌定植骨科种植体是一个主要原因失败和临床复杂的负荷金属种植体。局部或全身施用抗生素可能不能提供最有效的防御定植,特别是在继发性感染的情况下,导致手术切除植入物,在某些情况下甚至是肢体。在本研究中,采用激光粉末床熔接技术,将CpTi和Ti6Al4V粉末以1:1的重量混合制备Ti3Al2V合金。通过在Ti3Al2V定制合金中加入Ta和Cu,进一步分析了ti -钽(Ta)-铜(Cu)合金。对Ti3Al2V合金的生物、力学和摩擦-生物腐蚀性能进行了评价。在Ti3Al2V合金中加入10 wt.%的Ta (10Ta)和3 wt.%的Cu (3Cu)来增强生物相容性并赋予其固有的细菌抗性。研究了增材制造的植入物对铜绿假单胞菌和金黄色葡萄球菌菌株的耐药性长达48 h。添加3wt .% Cu的Ti3Al2V对CpTi的抗菌效果提高了78%-86%。对Ti3Al2V-10Ta-3Cu合金的力学性能进行了评估,结果表明,与Ti6Al4V相比,Ti3Al2V-10Ta-3Cu合金具有优异的抗疲劳性能、优异的抗剪切强度,以及更好的摩擦学和摩擦生物腐蚀特性。使用大鼠股骨远端模型进行的体内研究显示,与CpTi和Ti6Al4V相比,添加10% wt.% Ta的合金可以改善早期骨整合。添加3 wt.% cu的组合物在体内表现出生物相容性和无不良炎症反应。我们的研究结果表明,Ti3Al2V-10Ta-3Cu合金在提高下一代承重金属植入体的体内生物相容性和微生物耐药性方面具有协同效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Additively manufactured Ti-Ta-Cu alloys for the next-generation load-bearing implants.

Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum (Ta)-Copper (Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological, mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta (10Ta) and 3 wt.% Cu (3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against Pseudomonas aeruginosa and Staphylococcus aureus strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e. 78%-86% with respect to CpTi. Mechanical properties for Ti3Al2V-10Ta-3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. In vivo studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with 10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse inflammatory response in vivo. Our results establish the Ti3Al2V-10Ta-3Cu alloy's synergistic effect on improving both in vivo biocompatibility and microbial resistance for the next generation of load-bearing metallic implants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Extreme Manufacturing
International Journal of Extreme Manufacturing Engineering-Industrial and Manufacturing Engineering
CiteScore
17.70
自引率
6.10%
发文量
83
审稿时长
12 weeks
期刊介绍: The International Journal of Extreme Manufacturing (IJEM) focuses on publishing original articles and reviews related to the science and technology of manufacturing functional devices and systems with extreme dimensions and/or extreme functionalities. The journal covers a wide range of topics, from fundamental science to cutting-edge technologies that push the boundaries of currently known theories, methods, scales, environments, and performance. Extreme manufacturing encompasses various aspects such as manufacturing with extremely high energy density, ultrahigh precision, extremely small spatial and temporal scales, extremely intensive fields, and giant systems with extreme complexity and several factors. It encompasses multiple disciplines, including machinery, materials, optics, physics, chemistry, mechanics, and mathematics. The journal is interested in theories, processes, metrology, characterization, equipment, conditions, and system integration in extreme manufacturing. Additionally, it covers materials, structures, and devices with extreme functionalities.
期刊最新文献
Design and micromanufacturing technologies of focused piezoelectric ultrasound transducers for biomedical applications Design and additive manufacturing of bionic hybrid structure inspired by cuttlebone to achieve superior mechanical properties and shape memory function Holistic and localized preparation methods for triboelectric sensors: principles, applications and perspectives Recent Advances in Fabricating High-Performance Triboelectric Nanogenerators via Modulating Surface Charge Density Laser-Forged Transformation and Encapsulation of Nanoalloys: Pioneering Robust Wideband Electromagnetic Wave Absorption and Shielding from GHz to THz
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1