{"title":"电子显微镜中 Timepix3 混合像素探测器的时间校准研究","authors":"Yves Auad, Jassem Baaboura, Jean-Denis Blazit, Marcel Tencé, Odile Stéphan, Mathieu Kociak, Luiz H.G. Tizei","doi":"10.1016/j.ultramic.2023.113889","DOIUrl":null,"url":null,"abstract":"<div><p><span>Direct electron detection is currently revolutionizing many fields of electron microscopy<span> due to its lower noise, its reduced point-spread function, and its increased quantum efficiency. More specifically to this work, Timepix3 is a hybrid-pixel direct electron detector capable of outputting temporal information of individual hits in its pixel array. Its architecture results in a data-driven detector, also called event-based, in which individual hits trigger the data off the chip for readout as fast as possible. The presence of a pixel threshold value results in an almost readout-noise-free detector while also defining the hit time of arrival and the time the signal stays over the pixel threshold. In this work, we have performed various experiments to calibrate and correct the Timepix3 temporal information, specifically in the context of electron microscopy. These include the energy calibration, and the time-walk and pixel delay corrections, reaching an average temporal resolution throughout the entire pixel matrix of </span></span><span><math><mrow><mn>1</mn><mo>.</mo><mn>37</mn><mo>±</mo><mn>0</mn><mo>.</mo><mn>04</mn><mspace></mspace><mi>ns</mi></mrow></math></span><span>. Additionally, we have also studied cosmic rays tracks to characterize the charge dynamics along the volume of the sensor layer, allowing us to estimate the limits of the detector’s temporal response depending on different bias voltages, sensor thickness, and the electron beam ionization volume. We have estimated the uncertainty due to the ionization volume ranging from about 0.8 ns for 60 keV electrons to 8.8 ns for 300 keV electrons.</span></p></div>","PeriodicalId":23439,"journal":{"name":"Ultramicroscopy","volume":"257 ","pages":"Article 113889"},"PeriodicalIF":2.1000,"publicationDate":"2023-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Time calibration studies for the Timepix3 hybrid pixel detector in electron microscopy\",\"authors\":\"Yves Auad, Jassem Baaboura, Jean-Denis Blazit, Marcel Tencé, Odile Stéphan, Mathieu Kociak, Luiz H.G. Tizei\",\"doi\":\"10.1016/j.ultramic.2023.113889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><span>Direct electron detection is currently revolutionizing many fields of electron microscopy<span> due to its lower noise, its reduced point-spread function, and its increased quantum efficiency. More specifically to this work, Timepix3 is a hybrid-pixel direct electron detector capable of outputting temporal information of individual hits in its pixel array. Its architecture results in a data-driven detector, also called event-based, in which individual hits trigger the data off the chip for readout as fast as possible. The presence of a pixel threshold value results in an almost readout-noise-free detector while also defining the hit time of arrival and the time the signal stays over the pixel threshold. In this work, we have performed various experiments to calibrate and correct the Timepix3 temporal information, specifically in the context of electron microscopy. These include the energy calibration, and the time-walk and pixel delay corrections, reaching an average temporal resolution throughout the entire pixel matrix of </span></span><span><math><mrow><mn>1</mn><mo>.</mo><mn>37</mn><mo>±</mo><mn>0</mn><mo>.</mo><mn>04</mn><mspace></mspace><mi>ns</mi></mrow></math></span><span>. Additionally, we have also studied cosmic rays tracks to characterize the charge dynamics along the volume of the sensor layer, allowing us to estimate the limits of the detector’s temporal response depending on different bias voltages, sensor thickness, and the electron beam ionization volume. We have estimated the uncertainty due to the ionization volume ranging from about 0.8 ns for 60 keV electrons to 8.8 ns for 300 keV electrons.</span></p></div>\",\"PeriodicalId\":23439,\"journal\":{\"name\":\"Ultramicroscopy\",\"volume\":\"257 \",\"pages\":\"Article 113889\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultramicroscopy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0304399123002061\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MICROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultramicroscopy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0304399123002061","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MICROSCOPY","Score":null,"Total":0}
Time calibration studies for the Timepix3 hybrid pixel detector in electron microscopy
Direct electron detection is currently revolutionizing many fields of electron microscopy due to its lower noise, its reduced point-spread function, and its increased quantum efficiency. More specifically to this work, Timepix3 is a hybrid-pixel direct electron detector capable of outputting temporal information of individual hits in its pixel array. Its architecture results in a data-driven detector, also called event-based, in which individual hits trigger the data off the chip for readout as fast as possible. The presence of a pixel threshold value results in an almost readout-noise-free detector while also defining the hit time of arrival and the time the signal stays over the pixel threshold. In this work, we have performed various experiments to calibrate and correct the Timepix3 temporal information, specifically in the context of electron microscopy. These include the energy calibration, and the time-walk and pixel delay corrections, reaching an average temporal resolution throughout the entire pixel matrix of . Additionally, we have also studied cosmic rays tracks to characterize the charge dynamics along the volume of the sensor layer, allowing us to estimate the limits of the detector’s temporal response depending on different bias voltages, sensor thickness, and the electron beam ionization volume. We have estimated the uncertainty due to the ionization volume ranging from about 0.8 ns for 60 keV electrons to 8.8 ns for 300 keV electrons.
期刊介绍:
Ultramicroscopy is an established journal that provides a forum for the publication of original research papers, invited reviews and rapid communications. The scope of Ultramicroscopy is to describe advances in instrumentation, methods and theory related to all modes of microscopical imaging, diffraction and spectroscopy in the life and physical sciences.