Fekade Bruck Sime, Steven Wallis, Conor Jamieson, Tim Hills, Mark Gilchrist, Mark Santillo, R Andrew Seaton, Felicity Drummond, Jason Roberts
{"title":"评估阿昔洛韦在用于门诊肠外抗菌治疗的弹性输液器中的稳定性","authors":"Fekade Bruck Sime, Steven Wallis, Conor Jamieson, Tim Hills, Mark Gilchrist, Mark Santillo, R Andrew Seaton, Felicity Drummond, Jason Roberts","doi":"10.1136/ejhpharm-2023-003784","DOIUrl":null,"url":null,"abstract":"Objectives To investigate the stability of aciclovir solutions in elastomeric devices used for outpatient parenteral antimicrobial therapy (OPAT). Methods Triplicates of two elastomeric devices, Accufuser and Easypump II, were filled with a solution of 200 mg, 2400 mg, and 4500 mg aciclovir in 240 mL 0.9% w/v saline. Devices were stored at room temperature for 14 days, followed by 24 hours storage at 32°C. Assessment using a stability indicating assay, pH and subvisible particle analysis was undertaken at 11 time points throughout the study. Results Aciclovir solution at 200 mg and 2400 mg in 240 mL was stable for 14 days at room temperature (<20°C) and 24 hours of 32°C ‘in-use’ temperature exposure, remaining above the 95% limit for NHS stability protocols. The high dose was also stable for 14 days at room temperature, but when stored at 32°C there was precipitation of aciclovir within 4 hours in both devices. The precipitate was confirmed as aciclovir and precipitation was not a sign of chemical degradation. Conclusions Aciclovir concentrations above 2400 mg/240 mL are liable to precipitation and cannot be recommended for OPAT services because of heightened risks of nephrotoxicity. Aciclovir solution can be given as a continuous 24-hour infusion for OPAT services at a concentration range of 200–2400 mg in 240 mL in Accufuser and Easypump II elastomeric devices following 14 days storage at room temperature, protected from light. All data relevant to the study are included in the article or uploaded as supplementary information.","PeriodicalId":11998,"journal":{"name":"European Journal of Hospital Pharmacy","volume":"221 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the stability of aciclovir in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy\",\"authors\":\"Fekade Bruck Sime, Steven Wallis, Conor Jamieson, Tim Hills, Mark Gilchrist, Mark Santillo, R Andrew Seaton, Felicity Drummond, Jason Roberts\",\"doi\":\"10.1136/ejhpharm-2023-003784\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives To investigate the stability of aciclovir solutions in elastomeric devices used for outpatient parenteral antimicrobial therapy (OPAT). Methods Triplicates of two elastomeric devices, Accufuser and Easypump II, were filled with a solution of 200 mg, 2400 mg, and 4500 mg aciclovir in 240 mL 0.9% w/v saline. Devices were stored at room temperature for 14 days, followed by 24 hours storage at 32°C. Assessment using a stability indicating assay, pH and subvisible particle analysis was undertaken at 11 time points throughout the study. Results Aciclovir solution at 200 mg and 2400 mg in 240 mL was stable for 14 days at room temperature (<20°C) and 24 hours of 32°C ‘in-use’ temperature exposure, remaining above the 95% limit for NHS stability protocols. The high dose was also stable for 14 days at room temperature, but when stored at 32°C there was precipitation of aciclovir within 4 hours in both devices. The precipitate was confirmed as aciclovir and precipitation was not a sign of chemical degradation. Conclusions Aciclovir concentrations above 2400 mg/240 mL are liable to precipitation and cannot be recommended for OPAT services because of heightened risks of nephrotoxicity. Aciclovir solution can be given as a continuous 24-hour infusion for OPAT services at a concentration range of 200–2400 mg in 240 mL in Accufuser and Easypump II elastomeric devices following 14 days storage at room temperature, protected from light. All data relevant to the study are included in the article or uploaded as supplementary information.\",\"PeriodicalId\":11998,\"journal\":{\"name\":\"European Journal of Hospital Pharmacy\",\"volume\":\"221 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Hospital Pharmacy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1136/ejhpharm-2023-003784\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Hospital Pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/ejhpharm-2023-003784","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of the stability of aciclovir in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy
Objectives To investigate the stability of aciclovir solutions in elastomeric devices used for outpatient parenteral antimicrobial therapy (OPAT). Methods Triplicates of two elastomeric devices, Accufuser and Easypump II, were filled with a solution of 200 mg, 2400 mg, and 4500 mg aciclovir in 240 mL 0.9% w/v saline. Devices were stored at room temperature for 14 days, followed by 24 hours storage at 32°C. Assessment using a stability indicating assay, pH and subvisible particle analysis was undertaken at 11 time points throughout the study. Results Aciclovir solution at 200 mg and 2400 mg in 240 mL was stable for 14 days at room temperature (<20°C) and 24 hours of 32°C ‘in-use’ temperature exposure, remaining above the 95% limit for NHS stability protocols. The high dose was also stable for 14 days at room temperature, but when stored at 32°C there was precipitation of aciclovir within 4 hours in both devices. The precipitate was confirmed as aciclovir and precipitation was not a sign of chemical degradation. Conclusions Aciclovir concentrations above 2400 mg/240 mL are liable to precipitation and cannot be recommended for OPAT services because of heightened risks of nephrotoxicity. Aciclovir solution can be given as a continuous 24-hour infusion for OPAT services at a concentration range of 200–2400 mg in 240 mL in Accufuser and Easypump II elastomeric devices following 14 days storage at room temperature, protected from light. All data relevant to the study are included in the article or uploaded as supplementary information.