利用亲水相互作用色谱法结合串联质谱法对日本药典中的硫酸庆大霉素标准物质进行质量评估

IF 1.7 4区 农林科学 Q3 CHEMISTRY, ANALYTICAL Journal of AOAC International Pub Date : 2023-12-09 DOI:10.1093/jaoacint/qsad135
Keiko Maekawa, Ryuichi Sawa, Mari Matsui, Toshifumi Konda, Yumiko Kubota, Ayaka Matsuo, Akiho Maeda, Chisato Takahashi, Tsuyoshi Tanimoto, Yukari Nakagawa, Sachiyo Yoneda, Yuri Mori, Satowa Suzuki
{"title":"利用亲水相互作用色谱法结合串联质谱法对日本药典中的硫酸庆大霉素标准物质进行质量评估","authors":"Keiko Maekawa, Ryuichi Sawa, Mari Matsui, Toshifumi Konda, Yumiko Kubota, Ayaka Matsuo, Akiho Maeda, Chisato Takahashi, Tsuyoshi Tanimoto, Yukari Nakagawa, Sachiyo Yoneda, Yuri Mori, Satowa Suzuki","doi":"10.1093/jaoacint/qsad135","DOIUrl":null,"url":null,"abstract":"Background Through the recent development of analytical technology, antibiotics quantification in the Japanese Pharmacopoeia (JP) has changed from traditional microbiological assays to physicochemical methods with high specificity and precision. However, for several multicomponent antibiotics without typical UV absorption, potency cannot be directly determined using instrumental methods such as high-performance liquid chromatography; therefore, traditional microbiological assays are still used. Gentamicin sulfate (GmS), which consists of three major components, C1, C1a, and C2, is such a typical antibiotic, and its antimicrobial potency continues to be assayed using microbiological methods in JP monographs. Introduction of physicochemical assay for GmS is needed to help ensure its quality and quantity. Objective This study aimed to develop quality control measures for GmS that could be complimentary to quantitative assays and purity tests specified in the JP. Methods For each gentamicin C component (C1, C2, and C1a), theoretical potencies were determined based on the quantitative relationship between purity and potency, as measured by quantitative 1H NMR and microbiological assays, respectively. Two lots of the JP reference standard (RS) were used as test samples, with the contents of each component and impurity (sisomicin and garamine) being determined using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). Results The ratios of theoretical potency for C1, C2, and C1a were 1.00, 1.21, and 1.80, respectively. The potencies of the GmS JP RSs, which were estimated based on the contents and theoretical potency of each C component, corresponded well with those determined through microbiological assays. Marked differences in impurities (%) between the two RS lots were highlighted by quantifying sisomicin and garamine. Conclusion The developed analytical procedure enabled the characterization of two different JP RSs in terms of content ratio, potencies, and impurities. Highlights Novel analytical procedures useful for routine quality control of GmS were developed using HILIC-MS/MS.","PeriodicalId":15003,"journal":{"name":"Journal of AOAC International","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quality evaluation of gentamicin sulfate reference standards in Japanese Pharmacopoeia using hydrophilic interaction chromatography combined with tandem mass spectrometry\",\"authors\":\"Keiko Maekawa, Ryuichi Sawa, Mari Matsui, Toshifumi Konda, Yumiko Kubota, Ayaka Matsuo, Akiho Maeda, Chisato Takahashi, Tsuyoshi Tanimoto, Yukari Nakagawa, Sachiyo Yoneda, Yuri Mori, Satowa Suzuki\",\"doi\":\"10.1093/jaoacint/qsad135\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background Through the recent development of analytical technology, antibiotics quantification in the Japanese Pharmacopoeia (JP) has changed from traditional microbiological assays to physicochemical methods with high specificity and precision. However, for several multicomponent antibiotics without typical UV absorption, potency cannot be directly determined using instrumental methods such as high-performance liquid chromatography; therefore, traditional microbiological assays are still used. Gentamicin sulfate (GmS), which consists of three major components, C1, C1a, and C2, is such a typical antibiotic, and its antimicrobial potency continues to be assayed using microbiological methods in JP monographs. Introduction of physicochemical assay for GmS is needed to help ensure its quality and quantity. Objective This study aimed to develop quality control measures for GmS that could be complimentary to quantitative assays and purity tests specified in the JP. Methods For each gentamicin C component (C1, C2, and C1a), theoretical potencies were determined based on the quantitative relationship between purity and potency, as measured by quantitative 1H NMR and microbiological assays, respectively. Two lots of the JP reference standard (RS) were used as test samples, with the contents of each component and impurity (sisomicin and garamine) being determined using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). Results The ratios of theoretical potency for C1, C2, and C1a were 1.00, 1.21, and 1.80, respectively. The potencies of the GmS JP RSs, which were estimated based on the contents and theoretical potency of each C component, corresponded well with those determined through microbiological assays. Marked differences in impurities (%) between the two RS lots were highlighted by quantifying sisomicin and garamine. Conclusion The developed analytical procedure enabled the characterization of two different JP RSs in terms of content ratio, potencies, and impurities. Highlights Novel analytical procedures useful for routine quality control of GmS were developed using HILIC-MS/MS.\",\"PeriodicalId\":15003,\"journal\":{\"name\":\"Journal of AOAC International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of AOAC International\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1093/jaoacint/qsad135\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsad135","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景 随着近年来分析技术的发展,日本药典(JP)中的抗生素定量方法已从传统的微生物测定法转变为具有高特异性和高精确度的理化方法。然而,对于一些没有典型紫外线吸收的多组分抗生素,无法使用高效液相色谱等仪器方法直接确定其效价,因此仍在使用传统的微生物测定法。由 C1、C1a 和 C2 三种主要成分组成的硫酸庆大霉素(GmS)就是这样一种典型的抗生素,其抗菌效力在 JP 各论中仍采用微生物学方法进行测定。有必要引入 GmS 的理化检测方法,以帮助确保其质量和数量。本研究旨在制定 GmS 的质量控制措施,以补充 JP 中规定的定量测定和纯度测试。方法 根据定量 1H NMR 和微生物检测法分别测定的纯度和效价之间的定量关系,确定每种庆大霉素 C 成分(C1、C2 和 C1a)的理论效价。以两批 JP 标准物质(RS)作为测试样品,使用亲水作用液相色谱-串联质谱法(HILIC-MS/MS)测定各成分和杂质(西索米星和加拉敏)的含量。结果 C1、C2 和 C1a 的理论药效比分别为 1.00、1.21 和 1.80。根据每种 C 成分的含量和理论效价估算出的 GmS JP RS 效价与微生物检测确定的效价非常吻合。通过对西索米星和加拉敏进行定量,突出显示了两批 RS 之间杂质(%)的明显差异。结论 利用所开发的分析程序,可以对两种不同的太平绅士 RS 的含量比率、效力和杂质进行鉴定。亮点 利用 HILIC-MS/MS 开发出了适用于 GmS 常规质量控制的新型分析程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quality evaluation of gentamicin sulfate reference standards in Japanese Pharmacopoeia using hydrophilic interaction chromatography combined with tandem mass spectrometry
Background Through the recent development of analytical technology, antibiotics quantification in the Japanese Pharmacopoeia (JP) has changed from traditional microbiological assays to physicochemical methods with high specificity and precision. However, for several multicomponent antibiotics without typical UV absorption, potency cannot be directly determined using instrumental methods such as high-performance liquid chromatography; therefore, traditional microbiological assays are still used. Gentamicin sulfate (GmS), which consists of three major components, C1, C1a, and C2, is such a typical antibiotic, and its antimicrobial potency continues to be assayed using microbiological methods in JP monographs. Introduction of physicochemical assay for GmS is needed to help ensure its quality and quantity. Objective This study aimed to develop quality control measures for GmS that could be complimentary to quantitative assays and purity tests specified in the JP. Methods For each gentamicin C component (C1, C2, and C1a), theoretical potencies were determined based on the quantitative relationship between purity and potency, as measured by quantitative 1H NMR and microbiological assays, respectively. Two lots of the JP reference standard (RS) were used as test samples, with the contents of each component and impurity (sisomicin and garamine) being determined using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). Results The ratios of theoretical potency for C1, C2, and C1a were 1.00, 1.21, and 1.80, respectively. The potencies of the GmS JP RSs, which were estimated based on the contents and theoretical potency of each C component, corresponded well with those determined through microbiological assays. Marked differences in impurities (%) between the two RS lots were highlighted by quantifying sisomicin and garamine. Conclusion The developed analytical procedure enabled the characterization of two different JP RSs in terms of content ratio, potencies, and impurities. Highlights Novel analytical procedures useful for routine quality control of GmS were developed using HILIC-MS/MS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of AOAC International
Journal of AOAC International 医学-分析化学
CiteScore
3.10
自引率
12.50%
发文量
144
审稿时长
2.7 months
期刊介绍: The Journal of AOAC INTERNATIONAL publishes the latest in basic and applied research in analytical sciences related to foods, drugs, agriculture, the environment, and more. The Journal is the method researchers'' forum for exchanging information and keeping informed of new technology and techniques pertinent to regulatory agencies and regulated industries.
期刊最新文献
Bacterial Inactivation Studies in Shrimp Pond Water by using Different Disinfectant Agents Ivermectin-based products in the context of green pharmaceutical analysis Comparison of Roka Atlas® System Performance and Health Canada Reference Method for Listeria Detection from Plastic, Sealed Concrete, and Stainless Steel Surface Samples Determination of Aloin A, Aloin B, and Aloe-Emodin in Raw Materials and Finished Products Using HPLC Multi-Laboratory Validation Study, AOAC 2016.09, Final Action Status Determination of Toxic Elements in Botanical Dietary Supplement Ingredient Reference Materials
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1