Alaaddin Ibrahimy, Jocelyn Hoye, Hao Wu, Bart de Laat, Su Jin Kim, David L. Wilson, Evan D. Morris
{"title":"SLIC-Occ:占用图像的功能性分割提高了 EC50 图像的精确度","authors":"Alaaddin Ibrahimy, Jocelyn Hoye, Hao Wu, Bart de Laat, Su Jin Kim, David L. Wilson, Evan D. Morris","doi":"10.1186/s40658-023-00600-4","DOIUrl":null,"url":null,"abstract":"Drug occupancy studies with positron emission tomography imaging are used routinely in early phase drug development trials. Recently, our group introduced the Lassen Plot Filter, an extended version of the standard Lassen plot to estimate voxel-level occupancy images. Occupancy images can be used to create an EC50 image by applying an Emax model at each voxel. Our goal was to apply functional clustering of occupancy images via a clustering algorithm and produce a more precise EC50 image while maintaining accuracy. A digital brain phantom was used to create 10 occupancy images (corresponding to 10 different plasma concentrations of drug) that correspond to a ground truth EC50 image containing two bilateral local “hot spots” of high EC50 (region-1: 25; region-2: 50; background: 6–10 ng/mL). Maximum occupancy was specified as 0.85. An established noise model was applied to the simulated occupancy images and the images were smoothed. Simple Linear Iterative Clustering, an existing k-means clustering algorithm, was modified to segment a series of occupancy images into K clusters (which we call “SLIC-Occ”). EC50 images were estimated by nonlinear estimation at each cluster (post SLIC-Occ) and voxel (no clustering). Coefficient of variation images were estimated at each cluster and voxel, respectively. The same process was also applied to human occupancy data produced for a previously published study. Variability in EC50 estimates was reduced by more than 80% in the phantom data after application of SLIC-Occ to occupancy images with only minimal loss of accuracy. A similar, but more modest improvement was achieved in variability when SLIC-Occ was applied to human occupancy images. Our results suggest that functional segmentation of occupancy images via SLIC-Occ could produce more precise EC50 images and improve our ability to identify local “hot spots” of high effective affinity of a drug for its target(s).","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"15 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2023-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SLIC-Occ: functional segmentation of occupancy images improves precision of EC50 images\",\"authors\":\"Alaaddin Ibrahimy, Jocelyn Hoye, Hao Wu, Bart de Laat, Su Jin Kim, David L. Wilson, Evan D. Morris\",\"doi\":\"10.1186/s40658-023-00600-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Drug occupancy studies with positron emission tomography imaging are used routinely in early phase drug development trials. Recently, our group introduced the Lassen Plot Filter, an extended version of the standard Lassen plot to estimate voxel-level occupancy images. Occupancy images can be used to create an EC50 image by applying an Emax model at each voxel. Our goal was to apply functional clustering of occupancy images via a clustering algorithm and produce a more precise EC50 image while maintaining accuracy. A digital brain phantom was used to create 10 occupancy images (corresponding to 10 different plasma concentrations of drug) that correspond to a ground truth EC50 image containing two bilateral local “hot spots” of high EC50 (region-1: 25; region-2: 50; background: 6–10 ng/mL). Maximum occupancy was specified as 0.85. An established noise model was applied to the simulated occupancy images and the images were smoothed. Simple Linear Iterative Clustering, an existing k-means clustering algorithm, was modified to segment a series of occupancy images into K clusters (which we call “SLIC-Occ”). EC50 images were estimated by nonlinear estimation at each cluster (post SLIC-Occ) and voxel (no clustering). Coefficient of variation images were estimated at each cluster and voxel, respectively. The same process was also applied to human occupancy data produced for a previously published study. Variability in EC50 estimates was reduced by more than 80% in the phantom data after application of SLIC-Occ to occupancy images with only minimal loss of accuracy. A similar, but more modest improvement was achieved in variability when SLIC-Occ was applied to human occupancy images. Our results suggest that functional segmentation of occupancy images via SLIC-Occ could produce more precise EC50 images and improve our ability to identify local “hot spots” of high effective affinity of a drug for its target(s).\",\"PeriodicalId\":11559,\"journal\":{\"name\":\"EJNMMI Physics\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40658-023-00600-4\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-023-00600-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
SLIC-Occ: functional segmentation of occupancy images improves precision of EC50 images
Drug occupancy studies with positron emission tomography imaging are used routinely in early phase drug development trials. Recently, our group introduced the Lassen Plot Filter, an extended version of the standard Lassen plot to estimate voxel-level occupancy images. Occupancy images can be used to create an EC50 image by applying an Emax model at each voxel. Our goal was to apply functional clustering of occupancy images via a clustering algorithm and produce a more precise EC50 image while maintaining accuracy. A digital brain phantom was used to create 10 occupancy images (corresponding to 10 different plasma concentrations of drug) that correspond to a ground truth EC50 image containing two bilateral local “hot spots” of high EC50 (region-1: 25; region-2: 50; background: 6–10 ng/mL). Maximum occupancy was specified as 0.85. An established noise model was applied to the simulated occupancy images and the images were smoothed. Simple Linear Iterative Clustering, an existing k-means clustering algorithm, was modified to segment a series of occupancy images into K clusters (which we call “SLIC-Occ”). EC50 images were estimated by nonlinear estimation at each cluster (post SLIC-Occ) and voxel (no clustering). Coefficient of variation images were estimated at each cluster and voxel, respectively. The same process was also applied to human occupancy data produced for a previously published study. Variability in EC50 estimates was reduced by more than 80% in the phantom data after application of SLIC-Occ to occupancy images with only minimal loss of accuracy. A similar, but more modest improvement was achieved in variability when SLIC-Occ was applied to human occupancy images. Our results suggest that functional segmentation of occupancy images via SLIC-Occ could produce more precise EC50 images and improve our ability to identify local “hot spots” of high effective affinity of a drug for its target(s).
期刊介绍:
EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.