{"title":"基于污染物沉积的复合绝缘体结构优化模拟研究","authors":"V. Yukunl, Z. E. C. H. o, Q. I. W. Ang, U. Yaol, I. Xiaojingl","doi":"10.24425/aee.2023.147428","DOIUrl":null,"url":null,"abstract":": Optimizing the aerodynamic structure of composite insulators can guarantee the safe operation of power systems. In this study, we construct a simulation model for composite insulator contaminant deposition using the COMSOL simulation software, and the rationality of the simulation model and method is verified through wind tunnel experiments. Taking the FXBW4-110/100 composite insulator as an example, we adopt a progressive optimization plan to explore the impacts of shed spacing 𝑠 , and shed inclination angles 𝛼 and 𝛽 on its contaminant deposition characteristics under DC and AC voltages. Based on the numerical simulation results, we analyze the antifouling performance of insulators before and after structural optimization. The results indicate the following: 1) The contaminant deposition of the insulator under AC and DC voltages is negatively correlated with the shed spacing 𝑠 , but positively correlated with the lower inclination angle 𝛽 . 2) Under AC voltages, the contaminant deposition of the insulator increases with the upper inclination angle 𝛼 , while under DC voltages, the contaminant deposition shows an uptrend first, then a downtrend and then an uptrend again with the increase of the upper inclination angle 𝛼 . 3) Compared with the original model, the AC-optimized model ( 𝛼 = 6 ◦ , 𝛽 = 2 ◦ and 𝑠 = 98 mm) with a larger shed spacing 𝑠 , and smaller shed inclination angles 𝛼 and 𝛽 showed superior antifouling performance at wind speeds of no less than 2 m/s, and under the typical conditions ( 𝑣 = 2 . 5 m/s, 𝑑 = 20 μ m, and 𝜌 = 2200 kg/m 3 ), its contaminant deposition is 15% less than that of the original model ( 𝛼 = 10 ◦ , 𝛽 = 2 ◦ and 𝑠 = 80 mm).","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation study on the structural optimization of composite insulators based on contaminant deposition\",\"authors\":\"V. Yukunl, Z. E. C. H. o, Q. I. W. Ang, U. Yaol, I. Xiaojingl\",\"doi\":\"10.24425/aee.2023.147428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": Optimizing the aerodynamic structure of composite insulators can guarantee the safe operation of power systems. In this study, we construct a simulation model for composite insulator contaminant deposition using the COMSOL simulation software, and the rationality of the simulation model and method is verified through wind tunnel experiments. Taking the FXBW4-110/100 composite insulator as an example, we adopt a progressive optimization plan to explore the impacts of shed spacing 𝑠 , and shed inclination angles 𝛼 and 𝛽 on its contaminant deposition characteristics under DC and AC voltages. Based on the numerical simulation results, we analyze the antifouling performance of insulators before and after structural optimization. The results indicate the following: 1) The contaminant deposition of the insulator under AC and DC voltages is negatively correlated with the shed spacing 𝑠 , but positively correlated with the lower inclination angle 𝛽 . 2) Under AC voltages, the contaminant deposition of the insulator increases with the upper inclination angle 𝛼 , while under DC voltages, the contaminant deposition shows an uptrend first, then a downtrend and then an uptrend again with the increase of the upper inclination angle 𝛼 . 3) Compared with the original model, the AC-optimized model ( 𝛼 = 6 ◦ , 𝛽 = 2 ◦ and 𝑠 = 98 mm) with a larger shed spacing 𝑠 , and smaller shed inclination angles 𝛼 and 𝛽 showed superior antifouling performance at wind speeds of no less than 2 m/s, and under the typical conditions ( 𝑣 = 2 . 5 m/s, 𝑑 = 20 μ m, and 𝜌 = 2200 kg/m 3 ), its contaminant deposition is 15% less than that of the original model ( 𝛼 = 10 ◦ , 𝛽 = 2 ◦ and 𝑠 = 80 mm).\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/aee.2023.147428\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/aee.2023.147428","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

优化复合绝缘子的气动结构可以保证电力系统的安全运行。本研究利用COMSOL仿真软件构建了复合绝缘子污染物沉积的仿真模型,并通过风洞实验验证了仿真模型和方法的合理性。以FXBW4-110/100复合绝缘子为例,采用一种累进式优化方案,探讨了直流和交流电压下,绝缘子棚间距𝑠、绝缘子棚倾角、绝缘子棚倾角等参数对绝缘子污染物沉积特性的影响。根据数值模拟结果,分析了结构优化前后绝缘子的防污性能。结果表明:1)交直流电压下绝缘子的污染物沉降量与棚距𝑠呈负相关,与较低倾斜角时延成正相关。2)在交流电压下,绝缘子污物沉积随上倾角的增大而增大,而在直流电压下,随着上倾角的增大,污物沉积呈现先上升后下降再上升的趋势。3)与原始模型相比,AC-optimized模型(𝛼= 6◦𝛽= 2◦𝑠= 98毫米)和一个更大的间距𝑠,和小流倾斜角度𝛼和𝛽显示优良的防污性能的风速不少于2米/秒,和在典型条件下(𝑣= 2。5 m/s,𝑑= 20 μ m,𝜌= 2200 kg/m 3)时,污染物沉降比原模型(10◦,𝑠= 80mm)减少15%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulation study on the structural optimization of composite insulators based on contaminant deposition
: Optimizing the aerodynamic structure of composite insulators can guarantee the safe operation of power systems. In this study, we construct a simulation model for composite insulator contaminant deposition using the COMSOL simulation software, and the rationality of the simulation model and method is verified through wind tunnel experiments. Taking the FXBW4-110/100 composite insulator as an example, we adopt a progressive optimization plan to explore the impacts of shed spacing 𝑠 , and shed inclination angles 𝛼 and 𝛽 on its contaminant deposition characteristics under DC and AC voltages. Based on the numerical simulation results, we analyze the antifouling performance of insulators before and after structural optimization. The results indicate the following: 1) The contaminant deposition of the insulator under AC and DC voltages is negatively correlated with the shed spacing 𝑠 , but positively correlated with the lower inclination angle 𝛽 . 2) Under AC voltages, the contaminant deposition of the insulator increases with the upper inclination angle 𝛼 , while under DC voltages, the contaminant deposition shows an uptrend first, then a downtrend and then an uptrend again with the increase of the upper inclination angle 𝛼 . 3) Compared with the original model, the AC-optimized model ( 𝛼 = 6 ◦ , 𝛽 = 2 ◦ and 𝑠 = 98 mm) with a larger shed spacing 𝑠 , and smaller shed inclination angles 𝛼 and 𝛽 showed superior antifouling performance at wind speeds of no less than 2 m/s, and under the typical conditions ( 𝑣 = 2 . 5 m/s, 𝑑 = 20 μ m, and 𝜌 = 2200 kg/m 3 ), its contaminant deposition is 15% less than that of the original model ( 𝛼 = 10 ◦ , 𝛽 = 2 ◦ and 𝑠 = 80 mm).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1