使用高密度浆料的新型局部电镀方法与传统电解溶液的比较研究:铁样品铜镀层厚度和耐腐蚀性检验

Firas Alhachami
{"title":"使用高密度浆料的新型局部电镀方法与传统电解溶液的比较研究:铁样品铜镀层厚度和耐腐蚀性检验","authors":"Firas Alhachami","doi":"10.31185/ejuow.vol11.iss3.500","DOIUrl":null,"url":null,"abstract":"This paper presents a study on a new method of electroplating, using a high-density paste instead of traditional electrolytic solutions. The method was tested on iron samples, which were coated with copper. The thickness of the copper layer was measured using a leoi-44 experimental ellipsometer, revealing a thickness of 318 nm for the sample treated with the paste method, and 400 nm for the sample treated traditionally. The corrosion resistance of the samples was also tested, showing similar results for both methods. The paper concludes that this new method could be useful for treating specific areas of large or fixed metal objects, such as tanks or pipelines, and for artistic decoration on metals introduction.","PeriodicalId":184256,"journal":{"name":"Wasit Journal of Engineering Sciences","volume":"28 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Study on A Novel Local Electroplating Method Using High-Density Paste Versus Traditional Electrolytic Solutions: An Examination of Copper Coating Thickness and Corrosion Resistance on Iron Samples\",\"authors\":\"Firas Alhachami\",\"doi\":\"10.31185/ejuow.vol11.iss3.500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a study on a new method of electroplating, using a high-density paste instead of traditional electrolytic solutions. The method was tested on iron samples, which were coated with copper. The thickness of the copper layer was measured using a leoi-44 experimental ellipsometer, revealing a thickness of 318 nm for the sample treated with the paste method, and 400 nm for the sample treated traditionally. The corrosion resistance of the samples was also tested, showing similar results for both methods. The paper concludes that this new method could be useful for treating specific areas of large or fixed metal objects, such as tanks or pipelines, and for artistic decoration on metals introduction.\",\"PeriodicalId\":184256,\"journal\":{\"name\":\"Wasit Journal of Engineering Sciences\",\"volume\":\"28 10\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wasit Journal of Engineering Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31185/ejuow.vol11.iss3.500\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wasit Journal of Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31185/ejuow.vol11.iss3.500","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了一种新的电镀方法,用高密度浆料代替传统的电解溶液。该方法在涂有铜的铁样品上进行了测试。用leoi-44实验椭偏仪测量了铜层厚度,膏体法处理的铜层厚度为318 nm,传统处理的铜层厚度为400 nm。还测试了样品的耐腐蚀性,两种方法的结果相似。本文的结论是,这种新方法可以用于处理大型或固定金属物体的特定区域,如坦克或管道,以及金属介绍的艺术装饰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative Study on A Novel Local Electroplating Method Using High-Density Paste Versus Traditional Electrolytic Solutions: An Examination of Copper Coating Thickness and Corrosion Resistance on Iron Samples
This paper presents a study on a new method of electroplating, using a high-density paste instead of traditional electrolytic solutions. The method was tested on iron samples, which were coated with copper. The thickness of the copper layer was measured using a leoi-44 experimental ellipsometer, revealing a thickness of 318 nm for the sample treated with the paste method, and 400 nm for the sample treated traditionally. The corrosion resistance of the samples was also tested, showing similar results for both methods. The paper concludes that this new method could be useful for treating specific areas of large or fixed metal objects, such as tanks or pipelines, and for artistic decoration on metals introduction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficient Dye Removal and Water Treatment Feasibility Assessment for Iraq's Industrial Sector: A Case Study on Terasil Blue Dye Treatment Using Inverse Fluidized Bed and Adsorption A Deep Learning Approach to Evaluating SISO-OFDM Channel Equalization Numerical Investigation of the Impact of Subcooling Inlet on Water Flow Boiling Heat Transfer Through a Microchannel Effect of Metal Foam’s Volume on the Performance of a Double Pipe heat exchanger Flow field and heat transfer characteristics in dimple pipe with different shape of dimples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1