60Co:BIPM 的 Sir 测量对比

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION MAPAN Pub Date : 2023-12-14 DOI:10.1007/s12647-023-00702-5
Anuradha Ravindra, D. B. Kulkarni, Ritu Sharma, V. Sathian, Probal Chaudhury
{"title":"60Co:BIPM 的 Sir 测量对比","authors":"Anuradha Ravindra,&nbsp;D. B. Kulkarni,&nbsp;Ritu Sharma,&nbsp;V. Sathian,&nbsp;Probal Chaudhury","doi":"10.1007/s12647-023-00702-5","DOIUrl":null,"url":null,"abstract":"<div><p>The concept of equivalence was formulated to harmonize the different standards developed and maintained by national metrology institutes (NMIs) worldwide. Equivalence of a NMI with other NMIs or designated institute (DIs) is realized through international comparisons. International comparisons ensure the consistency and accuracy of measurements of various radionuclides that are carried out in laboratories worldwide. Organizing key comparisons by CCRI(II) meeting the requirement of NMIs/DIs for various radionuclides is challenging and cumbersome. Consequently, Syst`eme International de R´ef´erence (SIR), a system that enables NMIs to compare measurements standards over a wide spectrum of radionuclides, was approved by Section II of Consultative Committee on Ionising Radiation (CCRI II). Under this SIR intercomparison programme, BARC standardized radioactive solution of <sup>60</sup>Co by the primary methods using the 4<i>π β</i>-<i>γ</i> coincidence systems which are indigenously developed and maintained at BARC. The degree of equivalence (D<sub>i</sub>) of BARC for <sup>60</sup>Co (BIPM.RI(II)-K1.Co-60) comparison is D<sub>i</sub> =  − 13 ± 42 kBq at expanded uncertainty (<i>k</i> = 2). This comparison demonstrates the measurement equivalence for <sup>60</sup>Co, and inclusion of BARC equivalent activity in KCRV indicates the consistency of the measurements and the standards maintained at BARC. This paper describes the various methods used for standardizing <sup>60</sup>Co and the results of the comparison.</p></div>","PeriodicalId":689,"journal":{"name":"MAPAN","volume":"39 1","pages":"83 - 88"},"PeriodicalIF":1.0000,"publicationDate":"2023-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"International Equivalence of 60Co: Sir Measurements of BIPM Comparison\",\"authors\":\"Anuradha Ravindra,&nbsp;D. B. Kulkarni,&nbsp;Ritu Sharma,&nbsp;V. Sathian,&nbsp;Probal Chaudhury\",\"doi\":\"10.1007/s12647-023-00702-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The concept of equivalence was formulated to harmonize the different standards developed and maintained by national metrology institutes (NMIs) worldwide. Equivalence of a NMI with other NMIs or designated institute (DIs) is realized through international comparisons. International comparisons ensure the consistency and accuracy of measurements of various radionuclides that are carried out in laboratories worldwide. Organizing key comparisons by CCRI(II) meeting the requirement of NMIs/DIs for various radionuclides is challenging and cumbersome. Consequently, Syst`eme International de R´ef´erence (SIR), a system that enables NMIs to compare measurements standards over a wide spectrum of radionuclides, was approved by Section II of Consultative Committee on Ionising Radiation (CCRI II). Under this SIR intercomparison programme, BARC standardized radioactive solution of <sup>60</sup>Co by the primary methods using the 4<i>π β</i>-<i>γ</i> coincidence systems which are indigenously developed and maintained at BARC. The degree of equivalence (D<sub>i</sub>) of BARC for <sup>60</sup>Co (BIPM.RI(II)-K1.Co-60) comparison is D<sub>i</sub> =  − 13 ± 42 kBq at expanded uncertainty (<i>k</i> = 2). This comparison demonstrates the measurement equivalence for <sup>60</sup>Co, and inclusion of BARC equivalent activity in KCRV indicates the consistency of the measurements and the standards maintained at BARC. This paper describes the various methods used for standardizing <sup>60</sup>Co and the results of the comparison.</p></div>\",\"PeriodicalId\":689,\"journal\":{\"name\":\"MAPAN\",\"volume\":\"39 1\",\"pages\":\"83 - 88\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MAPAN\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12647-023-00702-5\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MAPAN","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s12647-023-00702-5","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

等效概念的提出是为了协调世界各国国家计量机构(NMI)制定和维护的不同标准。国家计量机构与其他国家计量机构或指定机构的等效性是通过国际比对实现的。国际比对可确保世界各地实验室对各种放射性核素进行测量的一致性和准确性。由 CCRI(II)组织关键比对以满足国家监测机构/指定机构对各种放射性核素的要求具有挑战性,而且非常繁琐。因此,电离辐射咨询委员会(CCRI II)第二部分批准了国际比对系统(SIR),该系统使国家监测机构能够对各种放射性核素的测量标准进行比对。在这一 SIR 相互比较计划下,BARC 使用本国开发和维护的 4π β-γ 重合系统,通过初级方法对 60Co 的放射性溶液进行了标准化。BARC 对 60Co (BIPM.RI(II)-K1.Co-60) 的比对等效度(Di)为 Di = - 13 ± 42 kBq(扩大不确定度)(k = 2)。这一对比结果表明了 60Co 的测量等效性,将 BARC 等效放射性活度纳入 KCRV 表明了 BARC 保持的测量和标准的一致性。本文介绍了用于 60Co 标准化的各种方法以及比较结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
International Equivalence of 60Co: Sir Measurements of BIPM Comparison

The concept of equivalence was formulated to harmonize the different standards developed and maintained by national metrology institutes (NMIs) worldwide. Equivalence of a NMI with other NMIs or designated institute (DIs) is realized through international comparisons. International comparisons ensure the consistency and accuracy of measurements of various radionuclides that are carried out in laboratories worldwide. Organizing key comparisons by CCRI(II) meeting the requirement of NMIs/DIs for various radionuclides is challenging and cumbersome. Consequently, Syst`eme International de R´ef´erence (SIR), a system that enables NMIs to compare measurements standards over a wide spectrum of radionuclides, was approved by Section II of Consultative Committee on Ionising Radiation (CCRI II). Under this SIR intercomparison programme, BARC standardized radioactive solution of 60Co by the primary methods using the 4π β-γ coincidence systems which are indigenously developed and maintained at BARC. The degree of equivalence (Di) of BARC for 60Co (BIPM.RI(II)-K1.Co-60) comparison is Di =  − 13 ± 42 kBq at expanded uncertainty (k = 2). This comparison demonstrates the measurement equivalence for 60Co, and inclusion of BARC equivalent activity in KCRV indicates the consistency of the measurements and the standards maintained at BARC. This paper describes the various methods used for standardizing 60Co and the results of the comparison.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
MAPAN
MAPAN 工程技术-物理:应用
CiteScore
2.30
自引率
20.00%
发文量
91
审稿时长
3 months
期刊介绍: MAPAN-Journal Metrology Society of India is a quarterly publication. It is exclusively devoted to Metrology (Scientific, Industrial or Legal). It has been fulfilling an important need of Metrologists and particularly of quality practitioners by publishing exclusive articles on scientific, industrial and legal metrology. The journal publishes research communication or technical articles of current interest in measurement science; original work, tutorial or survey papers in any metrology related area; reviews and analytical studies in metrology; case studies on reliability, uncertainty in measurements; and reports and results of intercomparison and proficiency testing.
期刊最新文献
Techniques for High Accuracy User Position Estimation Using NavIC Constellation Modified Refractivity-Based Lifted Index Using Exact Formula for Lifted Condensation Level Design and Performance Analysis of Graphene Integrated CPW Fed Fractal Antennae for 5G mm-Wave and Ground Based Navigation Applications A Novel Stepped-Flower Shaped UWB Frequency Reconfigurable Printed Filtering Antenna Using PIN Diodes with Trackable Notch-Band for Mid-5G Band & X-Band Applications Summer-Time Monitoring And Source Apportionment Study Of Both Coarse, Fine, And Ultra-Fine Particulate Pollution In Eastern Himalayan Darjeeling: A Hint To Health Risk During Peak Tourist Season
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1