{"title":"利用天线谐振尺度进行皮肤肉瘤分期检测","authors":"Dozohoua Silue, Mondher Labidi, Fethi Choubani","doi":"10.3233/jae-230048","DOIUrl":null,"url":null,"abstract":"In this paper, a small antenna is proposed to diagnose skin sarcoma at an embryonic stage. The antenna has an area of 30.54 × 15.27 mm2 and resonates at 1429 MHz with a reflection coefficient of −17.64 dB. The structure consists of a 35 μm copper sheet etched on a 1.6 mm FR-4 substrate. The diagnosis is based on the resonance frequency shift, and the SAR (Specific Absorption Rate) variation when the antenna is positioned on malignant tissue. For the simulations, a three-layer body phantom (skin, fat, muscle), and a half-sphere tumor phantom were considered. Simulations of the antenna performances showed that for a tumor of 100 μm, the resonant frequency, and the SAR decrease by 2 MHz, and 1.09 mW/Kg, respectively. In addition to sarcoma detection, the antenna’s 3.6 dBi gain allows for 124.47 m biomedical communication links in a complex environment.","PeriodicalId":50340,"journal":{"name":"International Journal of Applied Electromagnetics and Mechanics","volume":"13 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Skin sarcoma stage detection using antenna resonant scale\",\"authors\":\"Dozohoua Silue, Mondher Labidi, Fethi Choubani\",\"doi\":\"10.3233/jae-230048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a small antenna is proposed to diagnose skin sarcoma at an embryonic stage. The antenna has an area of 30.54 × 15.27 mm2 and resonates at 1429 MHz with a reflection coefficient of −17.64 dB. The structure consists of a 35 μm copper sheet etched on a 1.6 mm FR-4 substrate. The diagnosis is based on the resonance frequency shift, and the SAR (Specific Absorption Rate) variation when the antenna is positioned on malignant tissue. For the simulations, a three-layer body phantom (skin, fat, muscle), and a half-sphere tumor phantom were considered. Simulations of the antenna performances showed that for a tumor of 100 μm, the resonant frequency, and the SAR decrease by 2 MHz, and 1.09 mW/Kg, respectively. In addition to sarcoma detection, the antenna’s 3.6 dBi gain allows for 124.47 m biomedical communication links in a complex environment.\",\"PeriodicalId\":50340,\"journal\":{\"name\":\"International Journal of Applied Electromagnetics and Mechanics\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Electromagnetics and Mechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/jae-230048\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Electromagnetics and Mechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/jae-230048","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Skin sarcoma stage detection using antenna resonant scale
In this paper, a small antenna is proposed to diagnose skin sarcoma at an embryonic stage. The antenna has an area of 30.54 × 15.27 mm2 and resonates at 1429 MHz with a reflection coefficient of −17.64 dB. The structure consists of a 35 μm copper sheet etched on a 1.6 mm FR-4 substrate. The diagnosis is based on the resonance frequency shift, and the SAR (Specific Absorption Rate) variation when the antenna is positioned on malignant tissue. For the simulations, a three-layer body phantom (skin, fat, muscle), and a half-sphere tumor phantom were considered. Simulations of the antenna performances showed that for a tumor of 100 μm, the resonant frequency, and the SAR decrease by 2 MHz, and 1.09 mW/Kg, respectively. In addition to sarcoma detection, the antenna’s 3.6 dBi gain allows for 124.47 m biomedical communication links in a complex environment.
期刊介绍:
The aim of the International Journal of Applied Electromagnetics and Mechanics is to contribute to intersciences coupling applied electromagnetics, mechanics and materials. The journal also intends to stimulate the further development of current technology in industry. The main subjects covered by the journal are:
Physics and mechanics of electromagnetic materials and devices
Computational electromagnetics in materials and devices
Applications of electromagnetic fields and materials
The three interrelated key subjects – electromagnetics, mechanics and materials - include the following aspects: electromagnetic NDE, electromagnetic machines and devices, electromagnetic materials and structures, electromagnetic fluids, magnetoelastic effects and magnetosolid mechanics, magnetic levitations, electromagnetic propulsion, bioelectromagnetics, and inverse problems in electromagnetics.
The editorial policy is to combine information and experience from both the latest high technology fields and as well as the well-established technologies within applied electromagnetics.