{"title":"粘接树脂水泥、封闭材料和根部牙本质位置对玻璃纤维增强复合树脂桩固位的影响。","authors":"Zakereyya Sm Albashaireh, Buthaina Y Bashaireh, Bilal M El Masoud","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the effects of adhesive resin cement, obturation material and dentin location on the retention of glass fiber-reinforced resin composite (FRRC) posts.</p><p><strong>Methods: </strong>60 root canals in single rooted teeth were obturated with three different protocols (n= 20), including no obturation material (Control), GuttaFlow and Gutta-percha. Spaces were prepared for glass (FRCR) posts. Subgroups of the roots (n=10) were allocated for receiving posts luted with RelyX Unicem or Calibra resin cements. The specimens were mounted in plastic molds using epoxy resin. They were sectioned transversely to obtain three 1 mm-thick coronal, middle and apical slabs. Post retention was measured using a universal testing machine. The push-out test was performed at a crosshead speed of 0.5 mm/minute until post dislodgement occurred. Dislodged posts were examined microscopically to evaluate the mode of failure. Data were analyzed using univariate tests to reveal the effects of dependent variables and their interactions on post retention. Tukey test was used to determine significant differences for post retention in obturation material and dentin location groups. P-values ≤ 0.05 were considered significant.</p><p><strong>Results: </strong>The adhesive resin cement, obturation material, dentin location and cement obturation materials interaction affected post retention. The mean bond strength was higher for posts cemented with RelyX Unicem than for those cemented with Calibra resin cements. Post retention in coronal locations was significantly superior to middle or apical locations. The failure mode was primarily mixed.</p><p><strong>Clinical significance: </strong>When using RelyX Unicem cement for luting glass fiber-reinforced root canal posts, complete removal of all obturation materials from the post space significantly improves the retention. Although Calibra cement is less technique sensitive than RelyX Unicem resin cement, it produces notably lower retention of fiber-reinforced glass root canal posts.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of adhesive resin cement, obturation material and root dentin location on the retention of glass fiber-reinforced composite resin posts.\",\"authors\":\"Zakereyya Sm Albashaireh, Buthaina Y Bashaireh, Bilal M El Masoud\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the effects of adhesive resin cement, obturation material and dentin location on the retention of glass fiber-reinforced resin composite (FRRC) posts.</p><p><strong>Methods: </strong>60 root canals in single rooted teeth were obturated with three different protocols (n= 20), including no obturation material (Control), GuttaFlow and Gutta-percha. Spaces were prepared for glass (FRCR) posts. Subgroups of the roots (n=10) were allocated for receiving posts luted with RelyX Unicem or Calibra resin cements. The specimens were mounted in plastic molds using epoxy resin. They were sectioned transversely to obtain three 1 mm-thick coronal, middle and apical slabs. Post retention was measured using a universal testing machine. The push-out test was performed at a crosshead speed of 0.5 mm/minute until post dislodgement occurred. Dislodged posts were examined microscopically to evaluate the mode of failure. Data were analyzed using univariate tests to reveal the effects of dependent variables and their interactions on post retention. Tukey test was used to determine significant differences for post retention in obturation material and dentin location groups. P-values ≤ 0.05 were considered significant.</p><p><strong>Results: </strong>The adhesive resin cement, obturation material, dentin location and cement obturation materials interaction affected post retention. The mean bond strength was higher for posts cemented with RelyX Unicem than for those cemented with Calibra resin cements. Post retention in coronal locations was significantly superior to middle or apical locations. The failure mode was primarily mixed.</p><p><strong>Clinical significance: </strong>When using RelyX Unicem cement for luting glass fiber-reinforced root canal posts, complete removal of all obturation materials from the post space significantly improves the retention. Although Calibra cement is less technique sensitive than RelyX Unicem resin cement, it produces notably lower retention of fiber-reinforced glass root canal posts.</p>\",\"PeriodicalId\":7538,\"journal\":{\"name\":\"American journal of dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估粘接树脂水泥、封塞材料和牙本质位置对玻璃纤维增强树脂复合材料(FRRC)柱固位的影响。方法:采用三种不同的方案(n= 20)对 60 个单根牙根管进行封塞,包括不使用封塞材料(对照组)、GuttaFlow 和 Gutta-percha。为玻璃(FRCR)柱准备了空间。根部的子组(n=10)被分配接受用 RelyX Unicem 或 Calibra 树脂粘结剂粘结的柱子。使用环氧树脂将试样安装在塑料模具中。对试样进行横向切片,以获得三个 1 毫米厚的冠状、中间和根尖切片。使用万能试验机测量牙柱保持力。推出试验以 0.5 毫米/分钟的十字头速度进行,直到支柱脱落为止。对脱落的支柱进行显微镜检查,以评估失效模式。使用单变量检验对数据进行分析,以揭示因变量及其交互作用对支柱保留的影响。采用 Tukey 检验来确定封固材料组和牙本质位置组的柱保留率是否存在显著差异。P值≤0.05为差异显著:结果:粘接树脂、封闭材料、牙本质位置和粘接封闭材料的相互作用影响了桩固位。用 RelyX Unicem 粘接的柱体的平均粘接强度高于用 Calibra 树脂粘接剂粘接的柱体。冠部位置的基桩固位明显优于中部或根尖位置。失效模式主要是混合型:临床意义:在使用 RelyX Unicem 水泥粘接玻璃纤维增强根管柱时,完全去除根管柱空间中的所有封固材料可明显提高固位力。虽然 Calibra 水泥对技术的敏感性低于 RelyX Unicem 树脂水泥,但它对玻璃纤维增强根管柱的固位效果明显较差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effect of adhesive resin cement, obturation material and root dentin location on the retention of glass fiber-reinforced composite resin posts.

Purpose: To assess the effects of adhesive resin cement, obturation material and dentin location on the retention of glass fiber-reinforced resin composite (FRRC) posts.

Methods: 60 root canals in single rooted teeth were obturated with three different protocols (n= 20), including no obturation material (Control), GuttaFlow and Gutta-percha. Spaces were prepared for glass (FRCR) posts. Subgroups of the roots (n=10) were allocated for receiving posts luted with RelyX Unicem or Calibra resin cements. The specimens were mounted in plastic molds using epoxy resin. They were sectioned transversely to obtain three 1 mm-thick coronal, middle and apical slabs. Post retention was measured using a universal testing machine. The push-out test was performed at a crosshead speed of 0.5 mm/minute until post dislodgement occurred. Dislodged posts were examined microscopically to evaluate the mode of failure. Data were analyzed using univariate tests to reveal the effects of dependent variables and their interactions on post retention. Tukey test was used to determine significant differences for post retention in obturation material and dentin location groups. P-values ≤ 0.05 were considered significant.

Results: The adhesive resin cement, obturation material, dentin location and cement obturation materials interaction affected post retention. The mean bond strength was higher for posts cemented with RelyX Unicem than for those cemented with Calibra resin cements. Post retention in coronal locations was significantly superior to middle or apical locations. The failure mode was primarily mixed.

Clinical significance: When using RelyX Unicem cement for luting glass fiber-reinforced root canal posts, complete removal of all obturation materials from the post space significantly improves the retention. Although Calibra cement is less technique sensitive than RelyX Unicem resin cement, it produces notably lower retention of fiber-reinforced glass root canal posts.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American journal of dentistry
American journal of dentistry 医学-牙科与口腔外科
CiteScore
2.40
自引率
7.10%
发文量
57
审稿时长
1 months
期刊介绍: The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.
期刊最新文献
A comparison of polishing systems and thermal cycling on the surface roughness and color stability of a single-shade resin composite. Charcoal dentifrices: A laboratory study of their safety and efficacy. Current landscape of research on whitening toothpastes and their effects on dental hard tissue. Effects of salivary contamination on the shear bond strengths of universal adhesives to dentin. Framework's marginal adaptation evaluation of fixed partial denture using conventional and digital impression techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1