用于封堵坑洞和裂隙的不同材料的磨损行为。

IF 0.9 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE American journal of dentistry Pub Date : 2023-12-01
Dilan Kopuz, Bilal Yaşa, Hüseyin Hatirli
{"title":"用于封堵坑洞和裂隙的不同材料的磨损行为。","authors":"Dilan Kopuz, Bilal Yaşa, Hüseyin Hatirli","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the wear of different materials used for pit and fissure sealing applied with non-invasive and invasive preparation techniques.</p><p><strong>Methods: </strong>A total of 170 molar teeth were divided into two main preparation groups (non-invasive and invasive), each consisting of eight subgroups after a control group was separated for wear standardization. Eight subgroups included: nano-filled flowable composite (Filtek Ultimate Flow), nanohybrid flowable composite (GrandioSo Flow), micro-hybrid flowable composite (Majesty Flow), resin-based unfilled fissure sealant (ClinPro Sealant), resin-based filled fissure sealant (Fissurit FX), resin-based highly filled fissure sealant (GrandioSeal), giomer-based fissure sealant (BeautiSealant), and glass-ionomer-based fissure sealant (Fuji Triage) (n= 10). The materials were applied according to the manufacturers' instructions. The initial data were obtained for wear analysis. The specimens were subjected to 2-year thermocycling and brushing simulations. Final data were obtained, and the wear characteristics were evaluated digitally. Data were statistically analyzed (P< 0.05).</p><p><strong>Results: </strong>There were no significant differences in wear between the non-invasive and invasive application groups (P< 0.05). In comparison of the materials, flowable composites presented the lowest wear (0.15 P± 0.13), and glass-ionomer-based fissure sealant presented the highest wear (0.66 P± 0.32).</p><p><strong>Clinical significance: </strong>The present study reported that the invasive preparation technique, which slightly abrades the enamel surfaces, did not adversely affect the wear of the sealant materials. Although the application of flowable composites as fissure sealants with a bonding agent is time-consuming and costly, it yielded better results in terms of wear.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wear behavior of different materials used for pit and fissure sealing.\",\"authors\":\"Dilan Kopuz, Bilal Yaşa, Hüseyin Hatirli\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the wear of different materials used for pit and fissure sealing applied with non-invasive and invasive preparation techniques.</p><p><strong>Methods: </strong>A total of 170 molar teeth were divided into two main preparation groups (non-invasive and invasive), each consisting of eight subgroups after a control group was separated for wear standardization. Eight subgroups included: nano-filled flowable composite (Filtek Ultimate Flow), nanohybrid flowable composite (GrandioSo Flow), micro-hybrid flowable composite (Majesty Flow), resin-based unfilled fissure sealant (ClinPro Sealant), resin-based filled fissure sealant (Fissurit FX), resin-based highly filled fissure sealant (GrandioSeal), giomer-based fissure sealant (BeautiSealant), and glass-ionomer-based fissure sealant (Fuji Triage) (n= 10). The materials were applied according to the manufacturers' instructions. The initial data were obtained for wear analysis. The specimens were subjected to 2-year thermocycling and brushing simulations. Final data were obtained, and the wear characteristics were evaluated digitally. Data were statistically analyzed (P< 0.05).</p><p><strong>Results: </strong>There were no significant differences in wear between the non-invasive and invasive application groups (P< 0.05). In comparison of the materials, flowable composites presented the lowest wear (0.15 P± 0.13), and glass-ionomer-based fissure sealant presented the highest wear (0.66 P± 0.32).</p><p><strong>Clinical significance: </strong>The present study reported that the invasive preparation technique, which slightly abrades the enamel surfaces, did not adversely affect the wear of the sealant materials. Although the application of flowable composites as fissure sealants with a bonding agent is time-consuming and costly, it yielded better results in terms of wear.</p>\",\"PeriodicalId\":7538,\"journal\":{\"name\":\"American journal of dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估采用非侵入性和侵入性预备技术进行窝沟封闭时不同材料的磨损情况:将 170 颗磨牙分为两个主要预备组(非侵入式和侵入式),每个预备组由 8 个子组组成,然后再将一个对照组分开,以进行磨损标准化。八个分组包括纳米填充可流动复合材料(Filtek Ultimate Flow)、纳米混合可流动复合材料(GrandioSo Flow)、微混合可流动复合材料(Majesty Flow)、树脂基未填充裂隙封闭剂(ClinPro Sealant)、树脂基填充型窝沟封闭剂(Fissurit FX)、树脂基高填充型窝沟封闭剂(GrandioSeal)、giomer 基窝沟封闭剂(BeautiSealant)和玻璃-离子基窝沟封闭剂(Fuji Triage)(n= 10)。这些材料均按照制造商的说明使用。获得了用于磨损分析的初始数据。对试样进行为期 2 年的热循环和刷洗模拟。获得最终数据,并对磨损特性进行数字评估。对数据进行了统计分析(P< 0.05):结果:非侵入式和侵入式应用组在磨损方面没有明显差异(P< 0.05)。在材料比较中,可流动复合材料的磨损最小(0.15 P±0.13),玻璃-离子基裂隙封闭剂的磨损最大(0.66 P±0.32):本研究结果表明,微创预备技术虽然会轻微磨损牙釉质表面,但不会对封闭材料的磨损产生不利影响。虽然将可流动复合材料作为裂隙封闭剂与粘接剂一起使用既费时又费钱,但在磨损方面取得了更好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Wear behavior of different materials used for pit and fissure sealing.

Purpose: To evaluate the wear of different materials used for pit and fissure sealing applied with non-invasive and invasive preparation techniques.

Methods: A total of 170 molar teeth were divided into two main preparation groups (non-invasive and invasive), each consisting of eight subgroups after a control group was separated for wear standardization. Eight subgroups included: nano-filled flowable composite (Filtek Ultimate Flow), nanohybrid flowable composite (GrandioSo Flow), micro-hybrid flowable composite (Majesty Flow), resin-based unfilled fissure sealant (ClinPro Sealant), resin-based filled fissure sealant (Fissurit FX), resin-based highly filled fissure sealant (GrandioSeal), giomer-based fissure sealant (BeautiSealant), and glass-ionomer-based fissure sealant (Fuji Triage) (n= 10). The materials were applied according to the manufacturers' instructions. The initial data were obtained for wear analysis. The specimens were subjected to 2-year thermocycling and brushing simulations. Final data were obtained, and the wear characteristics were evaluated digitally. Data were statistically analyzed (P< 0.05).

Results: There were no significant differences in wear between the non-invasive and invasive application groups (P< 0.05). In comparison of the materials, flowable composites presented the lowest wear (0.15 P± 0.13), and glass-ionomer-based fissure sealant presented the highest wear (0.66 P± 0.32).

Clinical significance: The present study reported that the invasive preparation technique, which slightly abrades the enamel surfaces, did not adversely affect the wear of the sealant materials. Although the application of flowable composites as fissure sealants with a bonding agent is time-consuming and costly, it yielded better results in terms of wear.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American journal of dentistry
American journal of dentistry 医学-牙科与口腔外科
CiteScore
2.40
自引率
7.10%
发文量
57
审稿时长
1 months
期刊介绍: The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.
期刊最新文献
A comparison of polishing systems and thermal cycling on the surface roughness and color stability of a single-shade resin composite. Charcoal dentifrices: A laboratory study of their safety and efficacy. Current landscape of research on whitening toothpastes and their effects on dental hard tissue. Effects of salivary contamination on the shear bond strengths of universal adhesives to dentin. Framework's marginal adaptation evaluation of fixed partial denture using conventional and digital impression techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1