针对未接受胰岛素治疗的 2 型糖尿病患者的连续血糖监测系统:随机对照试验的系统回顾和荟萃分析。

IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes technology & therapeutics Pub Date : 2024-04-01 Epub Date: 2024-02-13 DOI:10.1089/dia.2023.0390
Rafael Oliva Morgado Ferreira, Talita Trevisan, Eric Pasqualotto, Matheus Pedrotti Chavez, Beatriz Friedrichsen Marques, Rodrigo Nunes Lamounier, Simone van de Sande-Lee
{"title":"针对未接受胰岛素治疗的 2 型糖尿病患者的连续血糖监测系统:随机对照试验的系统回顾和荟萃分析。","authors":"Rafael Oliva Morgado Ferreira, Talita Trevisan, Eric Pasqualotto, Matheus Pedrotti Chavez, Beatriz Friedrichsen Marques, Rodrigo Nunes Lamounier, Simone van de Sande-Lee","doi":"10.1089/dia.2023.0390","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Introduction:</i></b> Continuous glucose monitoring (CGM) has shown favorable outcomes in patients with type 2 diabetes (T2D) who are on insulin therapy. However, the efficacy of CGM in managing glucose levels in noninsulin-treated people with T2D remains controversial. <b><i>Methods:</i></b> PubMed, Cochrane, and Embase were searched for randomized controlled trials (RCTs) comparing CGM to self-monitoring of blood glucose (SMBG) in people with T2D not using insulin. We computed weighted mean differences (WMDs) and standard mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CIs). Heterogeneity was assessed using <i>I</i><sup>2</sup> statistics. Statistical analyses were performed using R version 4.2.3. <b><i>Results:</i></b> We included six RCTs comprising 407 noninsulin-treated people with T2D of whom 228 were randomized to CGM. Diabetes duration ranged from 5.4 to 13.9 years. The mean age was 57.9 years and the mean body mass index was 30.8 kg/m<sup>2</sup>. Four trials used real-time CGM (rt-CGM) and two intermittent scanning CGM (is-CGM). Compared with SMBG, CGM significantly reduced the glycated hemoglobin level (WMD -0.31%; 95% CI -0.42 to -0.21; <i>I</i><sup>2</sup> = 0%), glucose level (WMD -11.16 mg/dL; 95% CI -19.94 to -2.39; <i>I</i><sup>2</sup> = 0%), time in hypoglycemia level 2 (WMD -0.28%; 95% CI -0.52 to -0.03; <i>I</i><sup>2</sup> = 91%), glucose time >180 mg/dL (WMD -7.75%; 95% CI -12.04 to -3.45; <i>I</i><sup>2</sup> = 0%), and the standard deviation of glucose variation (WMD -4.00 mg/dL; 95% CI -6.86 to -1.14; <i>I</i><sup>2</sup> = 0%). CGM also increased time in range (WMD 8.63%; 95% CI 4.54-12.71; <i>I</i><sup>2</sup> = 0%) and treatment satisfaction (SMD 0.79; 95% CI 0.54-1.05; <i>I</i><sup>2</sup> = 0%). <b><i>Conclusion:</i></b> In this meta-analysis, rt-CGM and is-CGM were associated with improvement in glycemic control in people with T2D not using insulin when compared to SMBG.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous Glucose Monitoring Systems in Noninsulin-Treated People with Type 2 Diabetes: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.\",\"authors\":\"Rafael Oliva Morgado Ferreira, Talita Trevisan, Eric Pasqualotto, Matheus Pedrotti Chavez, Beatriz Friedrichsen Marques, Rodrigo Nunes Lamounier, Simone van de Sande-Lee\",\"doi\":\"10.1089/dia.2023.0390\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Introduction:</i></b> Continuous glucose monitoring (CGM) has shown favorable outcomes in patients with type 2 diabetes (T2D) who are on insulin therapy. However, the efficacy of CGM in managing glucose levels in noninsulin-treated people with T2D remains controversial. <b><i>Methods:</i></b> PubMed, Cochrane, and Embase were searched for randomized controlled trials (RCTs) comparing CGM to self-monitoring of blood glucose (SMBG) in people with T2D not using insulin. We computed weighted mean differences (WMDs) and standard mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CIs). Heterogeneity was assessed using <i>I</i><sup>2</sup> statistics. Statistical analyses were performed using R version 4.2.3. <b><i>Results:</i></b> We included six RCTs comprising 407 noninsulin-treated people with T2D of whom 228 were randomized to CGM. Diabetes duration ranged from 5.4 to 13.9 years. The mean age was 57.9 years and the mean body mass index was 30.8 kg/m<sup>2</sup>. Four trials used real-time CGM (rt-CGM) and two intermittent scanning CGM (is-CGM). Compared with SMBG, CGM significantly reduced the glycated hemoglobin level (WMD -0.31%; 95% CI -0.42 to -0.21; <i>I</i><sup>2</sup> = 0%), glucose level (WMD -11.16 mg/dL; 95% CI -19.94 to -2.39; <i>I</i><sup>2</sup> = 0%), time in hypoglycemia level 2 (WMD -0.28%; 95% CI -0.52 to -0.03; <i>I</i><sup>2</sup> = 91%), glucose time >180 mg/dL (WMD -7.75%; 95% CI -12.04 to -3.45; <i>I</i><sup>2</sup> = 0%), and the standard deviation of glucose variation (WMD -4.00 mg/dL; 95% CI -6.86 to -1.14; <i>I</i><sup>2</sup> = 0%). CGM also increased time in range (WMD 8.63%; 95% CI 4.54-12.71; <i>I</i><sup>2</sup> = 0%) and treatment satisfaction (SMD 0.79; 95% CI 0.54-1.05; <i>I</i><sup>2</sup> = 0%). <b><i>Conclusion:</i></b> In this meta-analysis, rt-CGM and is-CGM were associated with improvement in glycemic control in people with T2D not using insulin when compared to SMBG.</p>\",\"PeriodicalId\":11159,\"journal\":{\"name\":\"Diabetes technology & therapeutics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes technology & therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/dia.2023.0390\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2023.0390","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

简介连续血糖监测(CGM)在接受胰岛素治疗的 T2D 患者中显示出良好的效果。然而,CGM 对未接受胰岛素治疗的 T2D 患者控制血糖水平的效果仍存在争议:方法:我们在 PubMed、Cochrane 和 Embase 中检索了在未使用胰岛素的 T2D 患者中比较 CGM 与自我血糖监测 (SMBG) 的随机对照试验 (RCT)。我们计算了连续结果的加权平均差 (WMD) 和标准平均差 (SMD),以及 95% 置信区间 (95%CI)。异质性使用 I2 统计量进行评估。统计分析使用 R 4.2.3 版本进行:我们纳入了六项 RCT 研究,包括 407 名未经胰岛素治疗的 T2D 患者,其中 228 人随机接受了 CGM 治疗。糖尿病病程从 5.4 年到 13.9 年不等。平均年龄为 57.9 岁,平均体重指数为 30.8 kg/m2。四项试验使用实时 CGM(rt-CGM),两项使用间歇扫描 CGM(is-CGM)。与 SMBG 相比,CGM 显著降低了糖化血红蛋白(HbA1c)水平(WMD -0.31%;95%CI -0.42,-0.21;I2=0%)、血糖水平(WMD -11.16 mg/dl;95%CI -19.94,-2.39;I2=0%)、2 级低血糖时间(WMD -0.28%;95%CI -0.52,-0.03;I2=91%)、血糖 >180 mg/dl 时间(WMD -7.75%;95%CI -12.04,-3.45;I2=0%)和血糖变化标准差(WMD -4.00 mg/dl;95%CI -6.86,-1.14;I2=0%)。CGM还增加了在量程内的时间(WMD 8.63%;95%CI 4.54,12.71;I2=0%)和治疗满意度(SMD 0.79;95%CI 0.54,1.05;I2=0%):在这项荟萃分析中,与 SMBG 相比,rt-CGM 和 is-CGM 与改善未使用胰岛素的 T2D 患者的血糖控制有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous Glucose Monitoring Systems in Noninsulin-Treated People with Type 2 Diabetes: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Introduction: Continuous glucose monitoring (CGM) has shown favorable outcomes in patients with type 2 diabetes (T2D) who are on insulin therapy. However, the efficacy of CGM in managing glucose levels in noninsulin-treated people with T2D remains controversial. Methods: PubMed, Cochrane, and Embase were searched for randomized controlled trials (RCTs) comparing CGM to self-monitoring of blood glucose (SMBG) in people with T2D not using insulin. We computed weighted mean differences (WMDs) and standard mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CIs). Heterogeneity was assessed using I2 statistics. Statistical analyses were performed using R version 4.2.3. Results: We included six RCTs comprising 407 noninsulin-treated people with T2D of whom 228 were randomized to CGM. Diabetes duration ranged from 5.4 to 13.9 years. The mean age was 57.9 years and the mean body mass index was 30.8 kg/m2. Four trials used real-time CGM (rt-CGM) and two intermittent scanning CGM (is-CGM). Compared with SMBG, CGM significantly reduced the glycated hemoglobin level (WMD -0.31%; 95% CI -0.42 to -0.21; I2 = 0%), glucose level (WMD -11.16 mg/dL; 95% CI -19.94 to -2.39; I2 = 0%), time in hypoglycemia level 2 (WMD -0.28%; 95% CI -0.52 to -0.03; I2 = 91%), glucose time >180 mg/dL (WMD -7.75%; 95% CI -12.04 to -3.45; I2 = 0%), and the standard deviation of glucose variation (WMD -4.00 mg/dL; 95% CI -6.86 to -1.14; I2 = 0%). CGM also increased time in range (WMD 8.63%; 95% CI 4.54-12.71; I2 = 0%) and treatment satisfaction (SMD 0.79; 95% CI 0.54-1.05; I2 = 0%). Conclusion: In this meta-analysis, rt-CGM and is-CGM were associated with improvement in glycemic control in people with T2D not using insulin when compared to SMBG.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
Safety of Options to "Boost" (Enhancing Insulin Infusion Rates) and "Ease-Off" (Reducing Insulin Infusion Rates) in CamAPS FX Hybrid Closed-Loop System: A Real-World Analysis. Clinical Utility of Serum C-peptide Concentration for Hospitalized Patients with Hyperglycemia. An Automated Insulin Delivery System with Automatic Meal Bolus Based on a Hand-Gesturing Algorithm. Noninvasive Real-Time Glucose Monitoring Is in the Near Future. Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1