Allyson M Hynes, Shyam Murali, Gary A Bass, Tareq Kheirbek, Zaffer Qasim, Naomi George, Jay A Yelon, Kristen C Chreiman, Niels D Martin, Jeremy W Cannon
{"title":"对出现循环休克的患者使用胸骨内装置的效果:一项回顾性观察研究。","authors":"Allyson M Hynes, Shyam Murali, Gary A Bass, Tareq Kheirbek, Zaffer Qasim, Naomi George, Jay A Yelon, Kristen C Chreiman, Niels D Martin, Jeremy W Cannon","doi":"10.55460/AAZW-R052","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hemorrhagic shock requires timely administration of blood products and resuscitative adjuncts through multiple access sites. Intraosseous (IO) devices offer an alternative to intravenous (IV) access as recommended by the massive hemorrhage, A-airway, R-respiratory, C-circulation, and H-hypothermia (MARCH) algorithm of Tactical Combat Casualty Care (TCCC). However, venous injuries proximal to the site of IO access may complicate resuscitative attempts. Sternal IO access represents an alternative pioneered by military personnel. However, its effectiveness in patients with shock is supported by limited evidence. We conducted a pilot study of two sternal-IO devices to investigate the efficacy of sternal-IO access in civilian trauma care.</p><p><strong>Methods: </strong>A retrospective review (October 2020 to June 2021) involving injured patients receiving either a TALON® or a FAST1® sternal-IO device was performed at a large urban quaternary academic medical center. Baseline demographics, injury characteristics, vascular access sites, blood products and medications administered, and outcomes were analyzed. The primary outcome was a successful sternal-IO attempt.</p><p><strong>Results: </strong>Nine males with gunshot wounds transported to the hospital by police were included in this study. Eight patients were pulseless on arrival, and one became pulseless shortly thereafter. Seven (78%) sternal-IO placements were successful, including six TALON devices and one of the three FAST1 devices, as FAST1 placement required attention to Operator positioning following resuscitative thoracotomy. Three patients achieved return of spontaneous circulation, two proceeded to the operating room, but none survived to discharge.</p><p><strong>Conclusions: </strong>Sternal-IO access was successful in nearly 80% of attempts. The indications for sternal-IO placement among civilians require further evaluation compared with IV and extremity IO access.</p>","PeriodicalId":53630,"journal":{"name":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","volume":" ","pages":"81-86"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness of Sternal Intraosseous Device in Patients Presenting with Circulatory Shock: A Retrospective Observational Study.\",\"authors\":\"Allyson M Hynes, Shyam Murali, Gary A Bass, Tareq Kheirbek, Zaffer Qasim, Naomi George, Jay A Yelon, Kristen C Chreiman, Niels D Martin, Jeremy W Cannon\",\"doi\":\"10.55460/AAZW-R052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Hemorrhagic shock requires timely administration of blood products and resuscitative adjuncts through multiple access sites. Intraosseous (IO) devices offer an alternative to intravenous (IV) access as recommended by the massive hemorrhage, A-airway, R-respiratory, C-circulation, and H-hypothermia (MARCH) algorithm of Tactical Combat Casualty Care (TCCC). However, venous injuries proximal to the site of IO access may complicate resuscitative attempts. Sternal IO access represents an alternative pioneered by military personnel. However, its effectiveness in patients with shock is supported by limited evidence. We conducted a pilot study of two sternal-IO devices to investigate the efficacy of sternal-IO access in civilian trauma care.</p><p><strong>Methods: </strong>A retrospective review (October 2020 to June 2021) involving injured patients receiving either a TALON® or a FAST1® sternal-IO device was performed at a large urban quaternary academic medical center. Baseline demographics, injury characteristics, vascular access sites, blood products and medications administered, and outcomes were analyzed. The primary outcome was a successful sternal-IO attempt.</p><p><strong>Results: </strong>Nine males with gunshot wounds transported to the hospital by police were included in this study. Eight patients were pulseless on arrival, and one became pulseless shortly thereafter. Seven (78%) sternal-IO placements were successful, including six TALON devices and one of the three FAST1 devices, as FAST1 placement required attention to Operator positioning following resuscitative thoracotomy. Three patients achieved return of spontaneous circulation, two proceeded to the operating room, but none survived to discharge.</p><p><strong>Conclusions: </strong>Sternal-IO access was successful in nearly 80% of attempts. The indications for sternal-IO placement among civilians require further evaluation compared with IV and extremity IO access.</p>\",\"PeriodicalId\":53630,\"journal\":{\"name\":\"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals\",\"volume\":\" \",\"pages\":\"81-86\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55460/AAZW-R052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55460/AAZW-R052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Effectiveness of Sternal Intraosseous Device in Patients Presenting with Circulatory Shock: A Retrospective Observational Study.
Background: Hemorrhagic shock requires timely administration of blood products and resuscitative adjuncts through multiple access sites. Intraosseous (IO) devices offer an alternative to intravenous (IV) access as recommended by the massive hemorrhage, A-airway, R-respiratory, C-circulation, and H-hypothermia (MARCH) algorithm of Tactical Combat Casualty Care (TCCC). However, venous injuries proximal to the site of IO access may complicate resuscitative attempts. Sternal IO access represents an alternative pioneered by military personnel. However, its effectiveness in patients with shock is supported by limited evidence. We conducted a pilot study of two sternal-IO devices to investigate the efficacy of sternal-IO access in civilian trauma care.
Methods: A retrospective review (October 2020 to June 2021) involving injured patients receiving either a TALON® or a FAST1® sternal-IO device was performed at a large urban quaternary academic medical center. Baseline demographics, injury characteristics, vascular access sites, blood products and medications administered, and outcomes were analyzed. The primary outcome was a successful sternal-IO attempt.
Results: Nine males with gunshot wounds transported to the hospital by police were included in this study. Eight patients were pulseless on arrival, and one became pulseless shortly thereafter. Seven (78%) sternal-IO placements were successful, including six TALON devices and one of the three FAST1 devices, as FAST1 placement required attention to Operator positioning following resuscitative thoracotomy. Three patients achieved return of spontaneous circulation, two proceeded to the operating room, but none survived to discharge.
Conclusions: Sternal-IO access was successful in nearly 80% of attempts. The indications for sternal-IO placement among civilians require further evaluation compared with IV and extremity IO access.