Piper Lynn Wall, Charisse M Buising, Alex White, JaNiese Jensen, Justin Davis, Catherine Hackett Renner
{"title":"止血带功能对应用过程时间的影响。","authors":"Piper Lynn Wall, Charisse M Buising, Alex White, JaNiese Jensen, Justin Davis, Catherine Hackett Renner","doi":"10.55460/RPO1-CB79","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We investigated emergency-use limb tourniquet design features effects on application processes (companion paper) and times to complete those processes (this paper).</p><p><strong>Methods: </strong>Sixty-four appliers watched training videos then each applied all eight tourniquets: Combat Application Tour- niquet Generation 7 (CAT7), SOF™ Tactical Tourniquet-Wide Generation 3 (SOFTTW3), SOF™ Tactical Tourniquet-Wide Generation 5 (SOFTTW5), Tactical Mechanical Tourniquet (TMT), OMNA Marine Tourniquet (OMT), X8T-Tourniquet (X8T), Tactical Ratcheting Medical Tourniquet (Tac RMT), and RapidStop Tourniquet (RST). Application processes times were captured from videos.</p><p><strong>Results: </strong>From \"Go\" to \"touch tightening system\" was fastest with clips and self-securing redirect buckles and without strap/redirect application process problems (n, median seconds: CAT7 n=23, 26.89; SOFTTW3 n=11, 20.95; SOFTTW5 n=16, 20.53; TMT n=5, 26.61; OMT n=12, 25.94; X8T n=3, 18.44; Tac RMT n=15, 30.59; RST n=7, 22.80). From \"touch tightening system\" to \"last occlusion\" was fastest with windlass rod systems when there were no tightening system understanding or mechanical problems (seconds: CAT7 n=48, 4.21; SOFTTW3 n=47, 5.99; SOFTTW5 n=44, 4.65; TMT n=38, 6.21; OMT n=51, 6.22; X8T n=48, 7.59; Tac RMT n=52, 8.44; RST n=40, 8.02). For occluded, tightening system secure applications, from \"touch tightening system\" to \"Done\" was fastest with self-securing tightening systems tightening from a tight strap (occluded, secure time in seconds from a tight strap: CAT7 n=17, 14.47; SOFTTW3 n=22, 10.91; SOFTTW5 n=38, 9.19; TMT n=14, 11.42; OMT n=44, 7.01; X8T n=12 9.82; Tac RMT n=20, 6.45; RST n=23, 8.64).</p><p><strong>Conclusions: </strong>Suboptimal processes in- crease application times. Optimal design features for fast, occlusive, secure tourniquet applications are self-securing strap/ redirect systems with an easily identified and easily used clip and self-securing tightening systems.</p>","PeriodicalId":53630,"journal":{"name":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","volume":" ","pages":"31-42"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of Tourniquet Features on Application Processes Times.\",\"authors\":\"Piper Lynn Wall, Charisse M Buising, Alex White, JaNiese Jensen, Justin Davis, Catherine Hackett Renner\",\"doi\":\"10.55460/RPO1-CB79\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We investigated emergency-use limb tourniquet design features effects on application processes (companion paper) and times to complete those processes (this paper).</p><p><strong>Methods: </strong>Sixty-four appliers watched training videos then each applied all eight tourniquets: Combat Application Tour- niquet Generation 7 (CAT7), SOF™ Tactical Tourniquet-Wide Generation 3 (SOFTTW3), SOF™ Tactical Tourniquet-Wide Generation 5 (SOFTTW5), Tactical Mechanical Tourniquet (TMT), OMNA Marine Tourniquet (OMT), X8T-Tourniquet (X8T), Tactical Ratcheting Medical Tourniquet (Tac RMT), and RapidStop Tourniquet (RST). Application processes times were captured from videos.</p><p><strong>Results: </strong>From \\\"Go\\\" to \\\"touch tightening system\\\" was fastest with clips and self-securing redirect buckles and without strap/redirect application process problems (n, median seconds: CAT7 n=23, 26.89; SOFTTW3 n=11, 20.95; SOFTTW5 n=16, 20.53; TMT n=5, 26.61; OMT n=12, 25.94; X8T n=3, 18.44; Tac RMT n=15, 30.59; RST n=7, 22.80). From \\\"touch tightening system\\\" to \\\"last occlusion\\\" was fastest with windlass rod systems when there were no tightening system understanding or mechanical problems (seconds: CAT7 n=48, 4.21; SOFTTW3 n=47, 5.99; SOFTTW5 n=44, 4.65; TMT n=38, 6.21; OMT n=51, 6.22; X8T n=48, 7.59; Tac RMT n=52, 8.44; RST n=40, 8.02). For occluded, tightening system secure applications, from \\\"touch tightening system\\\" to \\\"Done\\\" was fastest with self-securing tightening systems tightening from a tight strap (occluded, secure time in seconds from a tight strap: CAT7 n=17, 14.47; SOFTTW3 n=22, 10.91; SOFTTW5 n=38, 9.19; TMT n=14, 11.42; OMT n=44, 7.01; X8T n=12 9.82; Tac RMT n=20, 6.45; RST n=23, 8.64).</p><p><strong>Conclusions: </strong>Suboptimal processes in- crease application times. Optimal design features for fast, occlusive, secure tourniquet applications are self-securing strap/ redirect systems with an easily identified and easily used clip and self-securing tightening systems.</p>\",\"PeriodicalId\":53630,\"journal\":{\"name\":\"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals\",\"volume\":\" \",\"pages\":\"31-42\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55460/RPO1-CB79\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55460/RPO1-CB79","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Effects of Tourniquet Features on Application Processes Times.
Background: We investigated emergency-use limb tourniquet design features effects on application processes (companion paper) and times to complete those processes (this paper).
Methods: Sixty-four appliers watched training videos then each applied all eight tourniquets: Combat Application Tour- niquet Generation 7 (CAT7), SOF™ Tactical Tourniquet-Wide Generation 3 (SOFTTW3), SOF™ Tactical Tourniquet-Wide Generation 5 (SOFTTW5), Tactical Mechanical Tourniquet (TMT), OMNA Marine Tourniquet (OMT), X8T-Tourniquet (X8T), Tactical Ratcheting Medical Tourniquet (Tac RMT), and RapidStop Tourniquet (RST). Application processes times were captured from videos.
Results: From "Go" to "touch tightening system" was fastest with clips and self-securing redirect buckles and without strap/redirect application process problems (n, median seconds: CAT7 n=23, 26.89; SOFTTW3 n=11, 20.95; SOFTTW5 n=16, 20.53; TMT n=5, 26.61; OMT n=12, 25.94; X8T n=3, 18.44; Tac RMT n=15, 30.59; RST n=7, 22.80). From "touch tightening system" to "last occlusion" was fastest with windlass rod systems when there were no tightening system understanding or mechanical problems (seconds: CAT7 n=48, 4.21; SOFTTW3 n=47, 5.99; SOFTTW5 n=44, 4.65; TMT n=38, 6.21; OMT n=51, 6.22; X8T n=48, 7.59; Tac RMT n=52, 8.44; RST n=40, 8.02). For occluded, tightening system secure applications, from "touch tightening system" to "Done" was fastest with self-securing tightening systems tightening from a tight strap (occluded, secure time in seconds from a tight strap: CAT7 n=17, 14.47; SOFTTW3 n=22, 10.91; SOFTTW5 n=38, 9.19; TMT n=14, 11.42; OMT n=44, 7.01; X8T n=12 9.82; Tac RMT n=20, 6.45; RST n=23, 8.64).
Conclusions: Suboptimal processes in- crease application times. Optimal design features for fast, occlusive, secure tourniquet applications are self-securing strap/ redirect systems with an easily identified and easily used clip and self-securing tightening systems.