Viral N Shah, Lauren G Kanapka, Halis K Akturk, Sarit Polsky, Gregory P Forlenza, Craig Kollman, Roy W Beck, Janet K Snell-Bergeon
{"title":"1型糖尿病成人的糖尿病视网膜病变与在射程内的时间有关:纵向研究","authors":"Viral N Shah, Lauren G Kanapka, Halis K Akturk, Sarit Polsky, Gregory P Forlenza, Craig Kollman, Roy W Beck, Janet K Snell-Bergeon","doi":"10.1089/dia.2023.0486","DOIUrl":null,"url":null,"abstract":"<p><p><b>Abstract</b> <b><i>Objective:</i></b> To evaluate the association between continuous glucose monitoring (CGM)-based time in various ranges and the subsequent development of diabetic retinopathy (incident DR) in adults with type 1 diabetes. <b><i>Methods:</i></b> Between June 2018 and March 2022, adults with type 1 diabetes with incident DR or no retinopathy (control) were identified. CGM data were collected retrospectively for up to 7 years before the date of eye examination defining incident DR or control. Associations between incident DR and CGM metrics were evaluated using logistic regression models. <b><i>Results:</i></b> This analysis included 71 adults with incident DR (mean age 27 years, 52% females, and mean diabetes duration 15 years) and 92 adults without DR (mean age 38 years, 48% females, and mean diabetes duration 20 years). Adjusting for age, diabetes duration, and CGM type, each 0.5% increase in glycated hemoglobin (HbA1c), 10 mg/dL increase in mean glucose, 5% decrease in time in target range 70-180 mg/dL (TIR), 5% decrease in time in tight target range 70-140 mg/dL (TITR), and 5% increase in time above 180 mg/dL (TAR) were associated with 24%, 22%, 18%, 28%, and 20% increase in odds of incident DR, respectively. Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ≥0.97. <b><i>Conclusion:</i></b> Similar to HbA1c, TIR, TITR, TAR, and mean glucose were associated with increased risk for incident DR in adults with type 1 diabetes. These CGM metrics are highly correlated indicating that they provide similar information on glycemic control and diabetic retinopathy risk.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Time in Range Is Associated with Incident Diabetic Retinopathy in Adults with Type 1 Diabetes: A Longitudinal Study.\",\"authors\":\"Viral N Shah, Lauren G Kanapka, Halis K Akturk, Sarit Polsky, Gregory P Forlenza, Craig Kollman, Roy W Beck, Janet K Snell-Bergeon\",\"doi\":\"10.1089/dia.2023.0486\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Abstract</b> <b><i>Objective:</i></b> To evaluate the association between continuous glucose monitoring (CGM)-based time in various ranges and the subsequent development of diabetic retinopathy (incident DR) in adults with type 1 diabetes. <b><i>Methods:</i></b> Between June 2018 and March 2022, adults with type 1 diabetes with incident DR or no retinopathy (control) were identified. CGM data were collected retrospectively for up to 7 years before the date of eye examination defining incident DR or control. Associations between incident DR and CGM metrics were evaluated using logistic regression models. <b><i>Results:</i></b> This analysis included 71 adults with incident DR (mean age 27 years, 52% females, and mean diabetes duration 15 years) and 92 adults without DR (mean age 38 years, 48% females, and mean diabetes duration 20 years). Adjusting for age, diabetes duration, and CGM type, each 0.5% increase in glycated hemoglobin (HbA1c), 10 mg/dL increase in mean glucose, 5% decrease in time in target range 70-180 mg/dL (TIR), 5% decrease in time in tight target range 70-140 mg/dL (TITR), and 5% increase in time above 180 mg/dL (TAR) were associated with 24%, 22%, 18%, 28%, and 20% increase in odds of incident DR, respectively. Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ≥0.97. <b><i>Conclusion:</i></b> Similar to HbA1c, TIR, TITR, TAR, and mean glucose were associated with increased risk for incident DR in adults with type 1 diabetes. These CGM metrics are highly correlated indicating that they provide similar information on glycemic control and diabetic retinopathy risk.</p>\",\"PeriodicalId\":11159,\"journal\":{\"name\":\"Diabetes technology & therapeutics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes technology & therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/dia.2023.0486\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2023.0486","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Time in Range Is Associated with Incident Diabetic Retinopathy in Adults with Type 1 Diabetes: A Longitudinal Study.
AbstractObjective: To evaluate the association between continuous glucose monitoring (CGM)-based time in various ranges and the subsequent development of diabetic retinopathy (incident DR) in adults with type 1 diabetes. Methods: Between June 2018 and March 2022, adults with type 1 diabetes with incident DR or no retinopathy (control) were identified. CGM data were collected retrospectively for up to 7 years before the date of eye examination defining incident DR or control. Associations between incident DR and CGM metrics were evaluated using logistic regression models. Results: This analysis included 71 adults with incident DR (mean age 27 years, 52% females, and mean diabetes duration 15 years) and 92 adults without DR (mean age 38 years, 48% females, and mean diabetes duration 20 years). Adjusting for age, diabetes duration, and CGM type, each 0.5% increase in glycated hemoglobin (HbA1c), 10 mg/dL increase in mean glucose, 5% decrease in time in target range 70-180 mg/dL (TIR), 5% decrease in time in tight target range 70-140 mg/dL (TITR), and 5% increase in time above 180 mg/dL (TAR) were associated with 24%, 22%, 18%, 28%, and 20% increase in odds of incident DR, respectively. Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ≥0.97. Conclusion: Similar to HbA1c, TIR, TITR, TAR, and mean glucose were associated with increased risk for incident DR in adults with type 1 diabetes. These CGM metrics are highly correlated indicating that they provide similar information on glycemic control and diabetic retinopathy risk.
期刊介绍:
Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.