Abdulrahman Almalki, Dennis Sourvanos, Noor Kutkut, Markus B Blatz, Vu Dang La, Joseph P Fiorellini, Rodrigo Neiva, Evanthia Anadioti
{"title":"使用两种不同的无夹板附着体系统对上颌和下颌磨制种植体固位覆盖义齿进行面部驱动的数字化工作流程:病例报告。","authors":"Abdulrahman Almalki, Dennis Sourvanos, Noor Kutkut, Markus B Blatz, Vu Dang La, Joseph P Fiorellini, Rodrigo Neiva, Evanthia Anadioti","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Unsplinted attachment systems for implant overdentures offer various benefits for edentulous patients, including cost-effectiveness, enhanced cleansability, and less need for manual dexterity. This article describes a facially driven digital workflow for fabricating a maxillary implant overdenture retained by conometric-style attachments (Atlantis® Conus) with a palateless design opposing an implant overdenture retained by standard attachments (LOCATOR®). This procedure provides a predictable and accurate technique to digitally scan the master casts with wax rims for articulation and to guide the digital teeth design set-up for a predictable esthetic outcome. The removable prosthesis workflow involves virtual teeth set-up, a 3D-printed trial denture, a milled definitive prosthesis, and intraoral pick-up for both unsplinted attachment systems. The clinical and laboratory steps are described.</p>","PeriodicalId":72651,"journal":{"name":"Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)","volume":"44 10","pages":"574-580"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Facially Driven Digital Workflow for Maxillary and Mandibular Milled Implant- Retained Overdentures Using Two Different Unsplinted Attachment Systems: Case Report.\",\"authors\":\"Abdulrahman Almalki, Dennis Sourvanos, Noor Kutkut, Markus B Blatz, Vu Dang La, Joseph P Fiorellini, Rodrigo Neiva, Evanthia Anadioti\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Unsplinted attachment systems for implant overdentures offer various benefits for edentulous patients, including cost-effectiveness, enhanced cleansability, and less need for manual dexterity. This article describes a facially driven digital workflow for fabricating a maxillary implant overdenture retained by conometric-style attachments (Atlantis® Conus) with a palateless design opposing an implant overdenture retained by standard attachments (LOCATOR®). This procedure provides a predictable and accurate technique to digitally scan the master casts with wax rims for articulation and to guide the digital teeth design set-up for a predictable esthetic outcome. The removable prosthesis workflow involves virtual teeth set-up, a 3D-printed trial denture, a milled definitive prosthesis, and intraoral pick-up for both unsplinted attachment systems. The clinical and laboratory steps are described.</p>\",\"PeriodicalId\":72651,\"journal\":{\"name\":\"Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)\",\"volume\":\"44 10\",\"pages\":\"574-580\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Facially Driven Digital Workflow for Maxillary and Mandibular Milled Implant- Retained Overdentures Using Two Different Unsplinted Attachment Systems: Case Report.
Unsplinted attachment systems for implant overdentures offer various benefits for edentulous patients, including cost-effectiveness, enhanced cleansability, and less need for manual dexterity. This article describes a facially driven digital workflow for fabricating a maxillary implant overdenture retained by conometric-style attachments (Atlantis® Conus) with a palateless design opposing an implant overdenture retained by standard attachments (LOCATOR®). This procedure provides a predictable and accurate technique to digitally scan the master casts with wax rims for articulation and to guide the digital teeth design set-up for a predictable esthetic outcome. The removable prosthesis workflow involves virtual teeth set-up, a 3D-printed trial denture, a milled definitive prosthesis, and intraoral pick-up for both unsplinted attachment systems. The clinical and laboratory steps are described.